Hardware compatibility list
Product version
For SAFEQ Cloud to send print job data to printers, a Document Output Service must be able to deliver data to the printers IP address on port 9100 or IPP (for more details see section Ports and Protocols in the documentation).
All devices (incl. devices not covered by the list) are compatible with YSoft SAFEQ offline accounting provided they support PCL, PostScript or HPGL print language.
All devices (incl. devices not covered by the list) are compatible with YSoft SAFEQ offline accounting provided they support PCL, PostScript or HPGL print language.
How can we help you?
Displayed parameters
(9 Selected)
Devices list
VendorPlease select... |
Model |
Family |
MFDShow compatible only |
A3Show compatible only |
ColorShow compatible only |
DuplexShow compatible only |
Smart cableShow compatible only |
Online accounting driverShow compatible only |
Pure Cloud TerminalShow compatible only |
Secondary Gateway Embedded TerminalShow compatible only |
Online Accounting Driver LimitationsShow compatible only |
Payment systemShow compatible only |
USB Card ReaderShow compatible only |
LD LicenseShow compatible only |
Finishing OptionsShow compatible only |
SAFEQ 5 Embedded TerminalShow compatible only |
SAFEQ 6 Embedded TerminalShow compatible only |
CommentShow compatible only |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Aurora | AD 400 MNF | Yes |
No |
No |
No |
No |
No |
Yes |
No |
Untested |
No |
No |
No |
No |
||||
Aurora | AD400MNF | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-BW-A4-8500 | No |
No |
Recommended driver: BROTHER-MFP-BW-A4-8500 Limitations: Status detection during scan is FALSEt supported. | No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 Build 41 is required to install Embedded Terminal to Aurora AD400MNF.
FW version bellow or newer supporting BSI is required to install Embedded Terminal.
Main Firmware Version: A
Sub1 Firmware Version: 1.00
Terminal type must be "Embedded Terminal for Brother", but NOT "Embedded Terminal for Aurora".
Scan workflows' setting "Sides -> Duplex" is not supported for Scanning from ADF. Scan does not start if Duplex is set and papers are set in ADF. (Device FW limitation. Release of the new FW with improvement is planned by the end of March 2020.)
Rule Base Engine "Watermark" does not work with AD400MNF printer driver which generates the proprietary command. Use YSF Universal Print Driver instead if you want to use Watermark.
|
|
Aurora | ADC225 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
req. SAFEQ-46592 | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested Controler ROM version for SafeQ5:
A90G0Y0-8100-G00-03
Authentication cache not yest tested for SafeQ 6.
|
||
Aurora | ADC265 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
req. SAFEQ-46592 | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested Controler ROM version for SafeQ5:
A90G0Y0-8100-G00-03
Authentication cache not yest tested for SafeQ 6.
|
||
Aurora | AD168 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB-210 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB-210 Limitations: There are 7 seconds timeouts after copy and print. Counters for copy and print are shared. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Only Konica Minolta controllers are supported. Online accounting does not work with external EFI controllers.
|
|
Aurora | AD218 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB-210 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB-210 Limitations: There are 7 seconds timeouts after copy and print. Counters for copy and print are shared. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Only Konica Minolta controllers are supported. Online accounting does not work with external EFI controllers.
|
|
Aurora | AD258 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
Only Konica Minolta controllers are supported. Online accounting does not work with external EFI controllers.
|
|
Aurora | AD358 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
Only Konica Minolta controllers are supported. Online accounting does not work with external EFI controllers.
|
|
Aurora | AD428 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
||
Aurora | AD508 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
||
Aurora | AD288 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Aurora | AD368 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Aurora | AD426 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 1,5GB (extended memory UK-201) Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 1,5GB (extended memory UK-201), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Aurora | AD506 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
Yes |
No |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 1,5GB (extended memory UK-201) Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 1,5GB (extended memory UK-201), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Aurora | AD166 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-211 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-211 Limitations: There is a 2 seconds timeout after print. There is a 2 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Aurora | AD216 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-211 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-211 Limitations: There is a 2 seconds timeout after print. There is a 2 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Aurora | AD219 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 Limitations: There are 3 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Aurora | AD289 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2 Limitations: There are 3 seconds timeouts after copy and print. Additional busy state recognition from number of active jobs. This driver is suitable for Mode2 accounting. Offline copy accounting enabled. A3 scan is accounted as 2xA4. Each scan is accounted also as a copy with 0 pages. Separate counters for print and copy. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Aurora | AD369 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2 Limitations: There are 3 seconds timeouts after copy and print. Additional busy state recognition from number of active jobs. This driver is suitable for Mode2 accounting. Offline copy accounting enabled. A3 scan is accounted as 2xA4. Each scan is accounted also as a copy with 0 pages. Separate counters for print and copy. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Aurora | AD429 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2 Limitations: There are 3 seconds timeouts after copy and print. Additional busy state recognition from number of active jobs. This driver is suitable for Mode2 accounting. Offline copy accounting enabled. A3 scan is accounted as 2xA4. Each scan is accounted also as a copy with 0 pages. Separate counters for print and copy. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Aurora | ADC258 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
||
Aurora | ADC256 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting Native with MyPanel: HDD: 250GB (HDD HD-516) Memory:1,5GB extended memory UK-201
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory:1,5GB extended memory UK-201, LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Aurora | ADC358 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting Native with MyPanel: HDD: 250GB (HDD HD-516) Memory:1,5GB extended memory UK-201
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory:1,5GB extended memory UK-201, LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Aurora | ADC218 | Yes |
Yes |
Yes |
Yes |
No |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
||
Aurora | ADC288 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
HDD: 250GB, Memory: 2GB
Native with MyPanel:
DD: 250GB Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel:
HDD: 250GB Memory: 3GB (extended memory UK-203) LK-101v2 iOption License Kit
Recommended latest FW for embedded terminal.
|
|
Aurora | ADC368 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
HDD: 250GB, Memory: 2GB
Native with MyPanel:
DD: 250GB Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel:
HDD: 250GB Memory: 3GB (extended memory UK-203) LK-101v2 iOption License Kit
Recommended latest FW for embedded terminal.
|
|
Aurora | ADC285 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB and Memory: 2GB built in by default
Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204)
Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58).
USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Card registration and billing code selection in the same authentication causes the terminal to stay in main authentication screen.
|
|
Aurora | ADC286 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Aurora | ADC366 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Aurora | ADC223 | Yes |
Yes |
Yes |
Yes |
No |
MIFALSELTA-MFP-COL-A3-C221-M1 / MIFALSELTA-MFP-COL-A3-C221-M2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-C221-M1 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 2 colors copy is accounted as a full-color copy. This driver is for "total counter mode 1" MFD setting. MIFALSELTA-MFP-COL-A3-C221-M2 here is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 2 colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) This driver is for "total counter mode 2" MFD setting. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Aurora | ADC283 | Yes |
Yes |
Yes |
Yes |
No |
MIFALSELTA-MFP-COL-A3-C221-M1 / MIFALSELTA-MFP-COL-A3-C221-M2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-C221-M1 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 2 colors copy is accounted as a full-color copy. This driver is for "total counter mode 1" MFD setting. MIFALSELTA-MFP-COL-A3-C221-M2 here is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 2 colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) This driver is for "total counter mode 2" MFD setting. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Aurora | ADC227 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW: A7970Y0-0100-G00-10(00) Supports SafeQ 6 Basic and Advanced Finishing Options. SafeQ 6 Universal Print Driver compatible.
|
|
Aurora | ADC287 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested FW: A7970Y0-0100-G00-10(00) Supports SafeQ 6 Basic and Advanced Finishing Options. SafeQ 6 Universal Print Driver compatible.
|
|
Aurora | ADC307 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
|
Aurora | ADC367 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
|
Aurora | ADC456 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Aurora | ADC556 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Aurora | ADC455 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5:
A79J0Y0-0100-G00-10
Tested FW for SafeQ 4: G00-21
|
|
Aurora | ADC555 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5: A79J0Y0-0100-G00-10
Tested FW for SafeQ 4: G00-21
|
|
Aurora | AD208 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 Limitations: There are 3 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Aurora | AD228 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 Limitations: There is 3 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Aurora | AD248 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 Limitations: There is 3 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Aurora | AD268 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 Limitations: There is 3 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Aurora | AD308 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 Limitations: There are 3 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Aurora | AD289e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
|
|
Aurora | AD369e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
|
|
Aurora | AD289S | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Recommended latest firmware (above G00-24).
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
|
Aurora | AD369S | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Recommended latest firmware (above G00-24).
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
|
Aurora | AD456 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
|
|
Aurora | AD556 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
|
|
Aurora | AD656 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. When blocked with Vender2 cable, online accounting does FALSEt work, machine is FALSEt increasing counters. This problem can be solved by using firmware version GD1-83 | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
|
|
Aurora | AD756 | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. When blocked with Vender2 cable, online accounting does FALSEt work, machine is FALSEt increasing counters. This problem can be solved by using firmware version GD1-83 | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
|
|
Aurora | AD775 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
No |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
||
Brother | MFC-L8390CDW | MFC | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Brother | MFC-L8340CDW | MFC | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Brother | HL-L8240CDW | HL | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Brother | HL-L8230CDW | HL | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Brother | MFC-6710DW | MFC | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Brother | MFC-L5710DW | MFC | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Brother | MFC-L5710DN | MFC | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
|||
Brother | DCP-L5510DW | DCP | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Brother | ADS-4900W | No |
No |
No |
No |
No |
No |
No |
Scanner Only | No |
Yes |
No |
No |
No |
No |
Scanner Only
|
||
Brother | ADS-4700W | No |
No |
No |
No |
No |
No |
No |
Scanner Only | No |
Untested |
No |
No |
No |
No |
|||
Brother | MFC-L6970DW | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
|||
Brother | MFC-L9577CDW | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
|||
Brother | MFC-8540DN | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
Brother Enhanced PCL driver recommended.
|
|||
Brother | HL-J6100DW | No |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 and newer
Requires EAP license
Brother Enhanced PCL driver recommended.
|
|||
Brother | HL-J6000DW | No |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
Brother Enhanced PCL driver recommended.
|
|||
Brother | MFC-J5945DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
Brother Enhanced PCL driver recommended.
|
|||
Brother | MFC-J6945DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
Brother Enhanced PCL driver recommended.
|
|||
Brother | HL-L8360CDW | No |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Tested model FW:
Main Firmware Version: 1.34
Sub1 Firmware Version: 1.14
Supported from MU27 with EAP license YSQL6-047-0000. Build 34 Summer 2019 and newer does not require EAP license YSQL6-047-0000.
Rule Base Engine limitations
RBE action "Watermark" work only with YSF Universal Print Driver or Brother Enhanced Generic PCL Driver on the model.
RBE action "Duplex" work only with YSF Universal Print Driver or Brother Enhanced Generic PCL Driver on the model
RBE action “Number of Copies” causes infinite print on the model on the model.
|
|||
Brother | MFC-L9670CDN | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-L9635CDN | MFC | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
|||
Brother | MFC-L9630CDN | MFC | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
|
||
Brother | MFC-L9610CDN | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-L6902DW | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-L5755DW | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-L5750DW | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-L5702DW | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-L5700DW | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J7600CDW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J7500CDW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J6999CDW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J6997CDW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | DCP-L5650DN | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-BW-A4-7065DN | No |
Yes |
Recommended driver: BROTHER-MFP-BW-A4-7065DN Limitations: Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. | No |
Yes |
No |
No |
No |
No |
||
Brother | MFC-L6700DW | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-BW-A4-7065DN | No |
Yes |
Recommended driver: BROTHER-MFP-BW-A4-7065DN Limitations: Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
Brother | MFC-L6900DW | Brother | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-BW-A4-7065DN | No |
Yes |
Recommended driver: BROTHER-MFP-BW-A4-7065DN Limitations: Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. | No |
Yes |
Yes |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
Brother | HL- 6180DW | Brother | No |
No |
No |
Yes |
No |
BROTHER-PRN-BW-A4-HL6180DW | No |
Yes |
Recommended driver:BROTHER-PRN-BW-A4-HL6180DW Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Brother | HL-5350DN | Brother | No |
No |
No |
Yes |
No |
BROTHER-PRN-COL-A4-HL4570 | No |
Yes |
Recommended driver:BROTHER-PRN-COL-A4-HL4570 Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Brother | HL-5250DN | Brother | No |
No |
No |
Yes |
No |
BROTHER-PRN-COL-A4-HL4570 | No |
Yes |
Recommended driver:BROTHER-PRN-COL-A4-HL4570 Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Brother | HL-4570CDW | Brother | No |
No |
Yes |
Yes |
No |
BROTHER-PRN-COL-A4-HL4570 | No |
Yes |
Recommended driver:BROTHER-PRN-COL-A4-HL4570 Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Brother | MFC-L8850CDW | Brother | Yes |
No |
Yes |
Yes |
No |
BROTHER-MFP-COL-A4-9020CDW | No |
Yes |
Recommended driver:BROTHER-MFP-COL-A4-9020CDW Limitations:If the device runs out of paper during print/copy, counter differences may occur.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. | No |
Untested |
No |
No |
No |
No |
|
Brother | MFC-L9550CDW | Brother | Yes |
No |
Yes |
Yes |
No |
BROTHER-MFP-COL-A4-9020CDW | No |
Yes |
Recommended driver:BROTHER-MFP-COL-A4-9020CDW Limitations:If the device runs out of paper during print/copy, counter differences may occur.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. | No |
Untested |
No |
No |
No |
No |
|
Brother | DCP-7055DCP-7055WDCP-7057DCP-7057WDCP-7060DDCP-7065DNDCP-7070DWMFC-7360MFC-7360NMFC-7362NMFC-7365DNMFC-7460DNMFC-7470DMFC-7820NMFC-7860DNMFC-7860DWFAX-7860DWHL-2280DW | Brother | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-BW-A4-7065DN | No |
Yes |
Recommended driver: BROTHER-MFP-BW-A4-7065DN Limitations: Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Brother | HL-S7000DN | Brother | No |
No |
No |
Yes |
No |
BROTHER-PRN-BW-A4-HLS7000DN | No |
Yes |
Recommended driver:BROTHER-PRN-BW-A4-HLS7000DN Limitations: There is a 1.5 second timeout after print. | No |
Untested |
No |
No |
No |
No |
|
Brother | MFC-9340CDW | Brother | Yes |
No |
Yes |
Yes |
No |
BROTHER-MFP-COL-A4-9020CDW | No |
Yes |
Recommended driver:BROTHER-MFP-COL-A4-9020CDW Limitations:If the device runs out of paper during print/copy, counter differences may occur.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. | No |
Untested |
No |
No |
No |
No |
|
Brother | MFC-9330CDW | Brother | Yes |
No |
Yes |
Yes |
No |
BROTHER-MFP-COL-A4-9020CDW | No |
Yes |
Recommended driver:BROTHER-MFP-COL-A4-9020CDW Limitations:If the device runs out of paper during print/copy, counter differences may occur.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. | No |
Untested |
No |
No |
No |
No |
|
Brother | MFC-9140CDN | Brother | Yes |
No |
Yes |
Yes |
No |
BROTHER-MFP-COL-A4-9020CDW | No |
Yes |
Recommended driver:BROTHER-MFP-COL-A4-9020CDW Limitations:If the device runs out of paper during print/copy, counter differences may occur.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. | No |
Untested |
No |
No |
No |
No |
|
Brother | MFC-9130CW | Brother | Yes |
No |
Yes |
Yes |
No |
BROTHER-MFP-COL-A4-9020CDW | No |
Yes |
Recommended driver:BROTHER-MFP-COL-A4-9020CDW Limitations:If the device runs out of paper during print/copy, counter differences may occur.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. | No |
Untested |
No |
No |
No |
No |
|
Brother | DCP-9020CDN | Brother | Yes |
No |
Yes |
Yes |
No |
BROTHER-MFP-COL-A4-9020CDW | No |
Yes |
Recommended driver: BROTHER-MFP-COL-A4-9020CDW Limitations: If the device runs out of paper during print/copy, counter differences may occur. Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. | No |
Untested |
No |
No |
No |
No |
YSoft SafeQ 6 MU30 and newer
|
Brother | DCP-9020CDW | Brother | Yes |
No |
Yes |
Yes |
No |
BROTHER-MFP-COL-A4-9020CDW | No |
Yes |
Recommended driver: BROTHER-MFP-COL-A4-9020CDW Limitations: If the device runs out of paper during print/copy, counter differences may occur. Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. | No |
Untested |
No |
No |
No |
No |
YSoft SafeQ 6 MU30 and newer
|
Brother | HL-4150CDN | Brother | No |
No |
Yes |
Yes |
No |
BROTHER-PRN-COL-A4-HL4140CN | No |
Yes |
Recommended driver:BROTHER-PRN-COL-A4-HL4140CN Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Brother | HL-4140CN | Brother | No |
No |
Yes |
Yes |
No |
BROTHER-PRN-COL-A4-HL4140CN | No |
Yes |
Recommended driver:BROTHER-PRN-COL-A4-HL4140CN Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Brother | HL-5470DW | Brother | No |
No |
No |
Yes |
No |
BROTHER-PRN-BW-A4-HL5440D | No |
Yes |
No |
Untested |
No |
No |
No |
No |
||
Brother | HL-5450DN | Brother | No |
No |
No |
Yes |
No |
BROTHER-PRN-BW-A4-HL5440D | No |
Yes |
No |
Untested |
No |
No |
No |
No |
||
Brother | HL-5440D | Brother | No |
No |
No |
Yes |
No |
BROTHER-PRN-BW-A4-HL5440D | No |
Yes |
No |
Untested |
No |
No |
No |
No |
||
Brother | DCP-9270CDN | Brother | Yes |
No |
Yes |
Yes |
No |
BROTHER-MFP-COL-9460CDN | No |
Yes |
Recommended driver:BROTHER-MFP-COL-9460CDN Limitations:Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. Scan from USB is FALSEt accounted. Status detection during scan is supported for following languages: English, Hungarian. | No |
Untested |
No |
No |
No |
No |
|
Brother | DCP-9055CDN | Brother | Yes |
No |
Yes |
Yes |
No |
BROTHER-MFP-COL-9460CDN | No |
Yes |
Recommended driver:BROTHER-MFP-COL-9460CDN Limitations:Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. Scan from USB is FALSEt accounted. Status detection during scan is supported for following languages: English, Hungarian. | No |
Untested |
No |
No |
No |
No |
|
Brother | MFC-9970CDW | Brother | Yes |
No |
Yes |
Yes |
No |
BROTHER-MFP-COL-9460CDN | No |
Yes |
Recommended driver:BROTHER-MFP-COL-9460CDN Limitations:Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. Scan from USB is FALSEt accounted. Status detection during scan is supported for following languages: English, Hungarian. | No |
Untested |
No |
No |
No |
No |
|
Brother | MFC-9460CDN | Brother | Yes |
No |
Yes |
Yes |
No |
BROTHER-MFP-COL-9460CDN | No |
Yes |
Recommended driver:BROTHER-MFP-COL-9460CDN Limitations:Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. Scan from USB is FALSEt accounted. Status detection during scan is supported for following languages: English, Hungarian. | No |
Untested |
No |
No |
No |
No |
|
Brother | MFC-8952DW | Brother | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-DUP-8950DW | No |
Yes |
No |
Untested |
No |
No |
No |
No |
||
Brother | MFC-8950DW | Brother | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-DUP-8950DW | No |
Yes |
No |
Untested |
No |
No |
No |
No |
||
Brother | MFC-8910DW | Brother | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-DUP-8950DW | No |
Yes |
No |
Untested |
No |
No |
No |
No |
||
Brother | MFC-8860DN | Brother | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-BW | No |
Yes |
Recommended driver:BROTHER-MFP-BW Limitations:Counters for copy and print are shared. Additional busy state recognition from special OID. | No |
Untested |
No |
No |
No |
No |
|
Brother | MFC-8520DN | Brother | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-DUP-8950DW | No |
Yes |
No |
Untested |
No |
No |
No |
No |
||
Brother | MFC-8510DN | Brother | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-DUP-8950DW | No |
Yes |
No |
Untested |
No |
No |
No |
No |
||
Brother | DCP-9045CDN | Brother | Yes |
No |
Yes |
Yes |
No |
BROTHER-MFP-COLOR | No |
Yes |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
|
Brother | DCP-8250DN | Brother | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-DUP-8950DW | No |
Yes |
No |
Untested |
No |
No |
No |
No |
||
Brother | DCP-8110DN | Brother | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-DUP-8950DW | No |
Yes |
No |
Untested |
No |
No |
No |
No |
||
Brother | HL-L6410DN | HL | No |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
|||
Brother | MFC-L6910DN | MFC | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP. |
||
Brother | ADS-3600W | No |
No |
No |
No |
No |
No |
No |
Scanner Only | No |
Yes |
No |
No |
No |
Yes |
Single function scanner - SafeQ Print application is not supported.
Firmware: P1907111512/M1512081018 and newer.
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
||
Brother | ADS-2800W | No |
No |
No |
No |
No |
No |
No |
Scanner only | No |
Yes |
No |
No |
No |
Yes |
Single function scanner - SafeQ Print application is not supported.
Firmware: P1907111512/M1512081018 and newer.
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
||
Brother | DCP-L6600DW | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 and newer
Requires EAP license
|
|||
Brother | MFC-L5750 | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
Requires EAP license
|
|||
Brother | MFC-L6800DW | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
|||
Brother | MFC-L6000DW | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
|||
Brother | MFC-L6950DW | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
|||
Brother | MFC-L9670DW | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
|||
Brother | HL-L6300DW/T | No |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
|||
Brother | HL-L6400DW/T | No |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
Yes |
No |
No |
Yes |
“/T” of HL-L6400DW/T stands for the Tower Tray.
Tested model FW:
Main Firmware Version: 1.80
Sub1 Firmware Version: 1.53
Supported from MU27 with EAP license YSQL6-047-0000. Build 34 Summer 2019 and newer does not require EAP license YSQL6-047-0000.
Rule Base Engine limitations
RBE action "Watermark" work only with YSF Universal Print Driver or Brother Enhanced Generic PCL Driver on the model.
RBE action "Duplex" work only with YSF Universal Print Driver or Brother Enhanced Generic PCL Driver on the model
RBE action “Number of Copies” causes infinite print on the model on the model.
|
|||
Brother | HL-L6450DN | No |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
|||
Brother | MFC-L8690CDW | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
|
|||
Brother | MFC-L8900CDW | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
|||
Brother | MFC-J6957DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J6955DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J6935DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J6930DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J6730DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J6580CDW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J6535DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J6530DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J5955DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J5930DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J5830DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J5730DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J5335DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J5330DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J3930DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J3530DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J2730DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-J2330DW | No |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-EX670W | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | MFC-EX670 | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | HL-L9470CDN | No |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | HL-L9430CDN | No |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | HL-L9410CDN | No |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | HL-L8360CDWT | No |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | HL-L6402DW | No |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | HL-L6400DWT | No |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | HL-J7010CDW | No |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | HL-J6010DW | No |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | HL-J6000CDW | No |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
Printer Only
|
|||
Brother | HL-EX470W | No |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | DCP-L5652DN | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
||||
Brother | DCP-L5602DN | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | DCP-L5600DN | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | DCP-L5502DN | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Brother | HL-L9310CDW(T) | No |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
|||
Brother | MFC-J6947DW | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
Brother Enhanced PCL driver recommended.
|
|||
Brother | DCP-L5500DN | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 and newer
Requires EAP license
|
|||
Brother | DCP-L8410CDW | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
Firmware from April 2019 and later required.
|
|||
Brother | MFC-L8610CDW | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
Firmware from April 2019 and later required.
|
|||
Brother | MFC-L9570CDW/T | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
|
|||
Brother | MFC-8535DN | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-BW-A4-8500 | No |
Yes |
Recommended driver: BROTHER-MFP-BW-A4-8500 Limitations: Status detection during scan is FALSEt supported. | No |
Untested |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
Brother Enhanced PCL driver recommended.
|
|
Brother | MFC-8530DN | Yes |
No |
No |
Yes |
No |
BROTHER-MFP-BW-A4-8500 | No |
Yes |
Recommended driver: BROTHER-MFP-BW-A4-8500 Limitations: Status detection during scan is FALSEt supported. | No |
Untested |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
Brother Enhanced PCL driver recommended.
|
|
Brother | HL-5595DN | No |
No |
No |
Yes |
No |
BROTHER-PRN-BW-A4-HLS7000DN-V2 | No |
Yes |
Recommended driver: BROTHER-PRN-BW-A4-HLS7000DN-V2 Limitations: There is a 1.5 second timeout after print. FALSEn-standard paper size prints are FALSEt accounted. | No |
Untested |
No |
No |
No |
No |
||
Brother | MFC-L5700DN | Yes |
No |
No |
Yes |
No |
BROTHER-PRN-BW-A4-5700DN | No |
Yes |
Recommended driver: BROTHER-PRN-BW-A4-5700DN Limitations: Status detection during scan is FALSEt supported | No |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU30 to Build 34 requires EAP license. Later versions without EAP.
Requires EAP license
|
|
Brother | HL-L6250DN | No |
No |
No |
Yes |
No |
BROTHER-PRN-BW-A4-HL6250DN | No |
Yes |
No |
Untested |
No |
No |
No |
No |
|||
Brother | MFC-L5715DN | MFC | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
|||
Brother | MFC-L6915DN | MFC | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
|||
Brother | HL-L5210DN | HL | No |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
|||
Brother | HL-L5215DN | HL | No |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
|||
Brother | HL-L6415DN | HL | No |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
|||
Brother | MFC-L2980DW | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
||||
Canon | LBP6670dn | i-SENSYS | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | CLC5151 | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Canon | CLC4040 | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Canon | W7200 | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Canon | PC-700 | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Canon | MF9280Cdn | i-SENSYS | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iR ADVC7270 | Image Runner | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iR ADV C7260 | Image Runner | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iR 6275i | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iR 6265i | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iR 6255i | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | MF8040Cn | i-SENSYS | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | MF4580dn | i-SENSYS | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | MF4570dn | i-SENSYS | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | LBP3000 | i-SENSYS | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | LBP6780x | i-SENSYS | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | LBP6750dn | i-SENSYS | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | LBP6680x | i-SENSYS | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | LBP6650dn | i-SENSYS | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | LBP6300dn | i-SENSYS | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | LBP7210Cdn | i-SENSYS | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | LBP7200Cdn | i-SENSYS | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iR 600V | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
Request: YSOFT-2014-17610 | No |
Untested |
No |
No |
No |
No |
||
Canon | iR 600 | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
Request: YSOFT-2014-17610 | No |
Untested |
No |
No |
No |
No |
||
Canon | iR 60 | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
Request: YSOFT-2014-17610 | No |
Untested |
No |
No |
No |
No |
||
Canon | iR 550 | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
Request: YSOFT-2014-17610 | No |
Untested |
No |
No |
No |
No |
||
Canon | iR 2320 | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
Request: YSOFT-2013-7303 Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR 2318 | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
Request: YSOFT-2013-7303 Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR 2030 | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
Request: YSOFT-2013-7303 Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR 2025 | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
Request: YSOFT-2013-7303 Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR 2022 | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
Request: YSOFT-2013-7303 Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR 2020 | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
Request: YSOFT-2013-7303 Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR 2018 | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
Request: YSOFT-2013-7303 Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR 2016 | Image Runner | Yes |
Yes |
No |
Yes |
No |
No |
No |
Request: YSOFT-2013-7303 Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
||
Canon | i-SENSYS MF5880dn | i-SENSYS | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | i-SENSYS MF4690PL | i-SENSYS | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iRC 5185i | Image Runner | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iRC 5180i | Image Runner | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iRC 4580i | Image Runner | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iRC 4080i | Image Runner | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iRC 1028i | Image Runner | Yes |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iR ADV C7065 | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
blocking cable requires addtional Canon Kit A1 with 9PIN DSUB connector
|
||
Canon | iRC 3480 | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iRC 3380 | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iRC 3080 | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iRC 2880 | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iRC 2550 | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iRC 2380 | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iR 3035 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Canon | iR-ADV C7580i | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iR75xx | No |
No |
Recommended driver: CAFALSEN-MFP-COL-A3-iR75xx Limitations: Counters for copy and print are shared. There is a 3 second timeout after print. There is a 3 second timeout after copy. If device runs out of paper during print/copy, counter differences may occur. Scan to USB is FALSEt accounted. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR-ADV C7570i | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iR75xx | No |
No |
Recommended driver: CAFALSEN-MFP-COL-A3-iR75xx Limitations: Counters for copy and print are shared. There is a 3 second timeout after print. There is a 3 second timeout after copy. If device runs out of paper during print/copy, counter differences may occur. Scan to USB is FALSEt accounted. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR-ADV C7565i | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iR75xx | No |
No |
Recommended driver: CAFALSEN-MFP-COL-A3-iR75xx Limitations: Counters for copy and print are shared. There is a 3 second timeout after print. There is a 3 second timeout after copy. If device runs out of paper during print/copy, counter differences may occur. Scan to USB is FALSEt accounted. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR-ADV C355iFC | Yes |
No |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A4-iRC355 | No |
No |
Recommended driver: CAFALSEN-MFP-COL-A4-iRC355 Limitations: If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. If device runs out of paper during print/copy, counter differences may occur. There is a 2 second timeout after print. There is a 2 second timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR-ADV C355 | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-COL-A4-iRC355 | No |
No |
Recommended driver: CAFALSEN-MFP-COL-A4-iRC355 Limitations: If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. If device runs out of paper during print/copy, counter differences may occur. There is a 2 second timeout after print. There is a 2 second timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR-ADV C355i | Yes |
No |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A4-iRC355 | No |
No |
Recommended driver: CAFALSEN-MFP-COL-A4-iRC355 Limitations: If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. If device runs out of paper during print/copy, counter differences may occur. There is a 2 second timeout after print. There is a 2 second timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR-ADV C255i | Yes |
No |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A4-iRC355 | No |
No |
Recommended driver: CAFALSEN-MFP-COL-A4-iRC355 Limitations: If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. If device runs out of paper during print/copy, counter differences may occur. There is a 2 second timeout after print. There is a 2 second timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR-ADV C5560i | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iR52xx | No |
Yes |
Recommended driver: CAFALSEN-MFP-COL-A3-iR52xx Limitations: Counters for copy and print are shared. There is a 1 second timeout after print. There is a 1 second timeout after copy. Scan to USB is FALSEt accounted. | No |
Untested |
No |
Yes |
No |
No |
||
Canon | iR-ADV C5550i | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iR52xx | No |
Yes |
Recommended driver: CAFALSEN-MFP-COL-A3-iR52xx Limitations: Counters for copy and print are shared. There is a 1 second timeout after print. There is a 1 second timeout after copy. Scan to USB is FALSEt accounted. | No |
Untested |
No |
Yes |
No |
No |
||
Canon | iR-ADV C5540i | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iR52xx | No |
Yes |
Recommended driver: CAFALSEN-MFP-COL-A3-iR52xx Limitations: Counters for copy and print are shared. There is a 1 second timeout after print. There is a 1 second timeout after copy. Scan to USB is FALSEt accounted. | No |
Untested |
No |
Yes |
No |
No |
||
Canon | iR-ADV C5540 | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iR52xx | No |
Yes |
Recommended driver: CAFALSEN-MFP-COL-A3-iR52xx Limitations: Counters for copy and print are shared. There is a 1 second timeout after print. There is a 1 second timeout after copy. Scan to USB is FALSEt accounted. | No |
Untested |
No |
Yes |
No |
No |
||
Canon | iR-ADV C5535 | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iR52xx | No |
Yes |
Recommended driver: CAFALSEN-MFP-COL-A3-iR52xx Limitations: Counters for copy and print are shared. There is a 1 second timeout after print. There is a 1 second timeout after copy. Scan to USB is FALSEt accounted. | No |
Untested |
No |
Yes |
No |
No |
||
Canon | iR-ADV 8295 | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR8205 | No |
No |
There is a 1 second timeout after print. There is a 1 second timeout after copy. Scan to USB is FALSEt accounted. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR-ADV 8285 | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR8205 | No |
No |
There is a 1 second timeout after print. There is a 1 second timeout after copy. Scan to USB is FALSEt accounted. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR-ADV 8205 | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR8205 | No |
No |
There is a 1 second timeout after print. There is a 1 second timeout after copy. Scan to USB is FALSEt accounted. | No |
Untested |
No |
No |
No |
No |
||
Canon | iR ADV 4251i | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR42xx | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A3-iR42xx Limitations:Counters for copy and print are shared.There is a 1 second timeout after print.There is a 1 second timeout after copy.Scan to USB is FALSEt accounted. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV 4245i | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR42xx | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A3-iR42xx Limitations:Counters for copy and print are shared.There is a 1 second timeout after print.There is a 1 second timeout after copy.Scan to USB is FALSEt accounted. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV 4235i | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR42xx | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A3-iR42xx Limitations:Counters for copy and print are shared.There is a 1 second timeout after print.There is a 1 second timeout after copy.Scan to USB is FALSEt accounted. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV 4225i | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR42xx | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A3-iR42xx Limitations:Counters for copy and print are shared.There is a 1 second timeout after print.There is a 1 second timeout after copy.Scan to USB is FALSEt accounted. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV 500i | Image Runner | Yes |
No |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A4-400i | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A4-400i Limitations:There is a 500 ms timeout after copy.If device runs out of paper during print, jobs are accounted after the paper is refilled. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV 400i | Image Runner | Yes |
No |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A4-400i | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A4-400i Limitations:There is a 500 ms timeout after copy.If device runs out of paper during print, jobs are accounted after the paper is refilled. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV C351iF | Image Runner | Yes |
No |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A4-iRC351 | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A4-iRC351 Limitations:If device runs out of paper during print/copy, jobs are accounted after the paper is refilled.There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
blocking cable requires addtional Canon Kit A1 with 9PIN DSUB connector
|
Canon | iR ADV C350i | Image Runner | Yes |
No |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A4-iRC351 | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A4-iRC351 Limitations:If device runs out of paper during print/copy, jobs are accounted after the paper is refilled.There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
blocking cable requires addtional Canon Kit A1 with 9PIN DSUB connector
|
Canon | iR ADV C250i | Image Runner | Yes |
No |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A4-iRC351 | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A4-iRC351 Limitations:If device runs out of paper during print/copy, jobs are accounted after the paper is refilled.There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
blocking cable requires addtional Canon Kit A1 with 9PIN DSUB connector
|
Canon | iR ADV C5255i | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iR52xx | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iR52xx Limitations: Counters for copy and print are shared.There is a 1 second timeout after print.There is a 1 second timeout after copy.Scan to USB is FALSEt accounted. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV C5250i | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iR52xx | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iR52xx Limitations: Counters for copy and print are shared.There is a 1 second timeout after print.There is a 1 second timeout after copy.Scan to USB is FALSEt accounted. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV C5245i | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iR52xx | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iR52xx Limitations: Counters for copy and print are shared.There is a 1 second timeout after print.There is a 1 second timeout after copy.Scan to USB is FALSEt accounted. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV C5240i | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iR52xx | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iR52xx Limitations: Counters for copy and print are shared.There is a 1 second timeout after print.There is a 1 second timeout after copy.Scan to USB is FALSEt accounted. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV C5235i | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iR52xx | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iR52xx Limitations: Counters for copy and print are shared.There is a 1 second timeout after print.There is a 1 second timeout after copy.Scan to USB is FALSEt accounted. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 1750i | Image Runner | Yes |
No |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A4-IR1133 | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A4-IR1133 Limitations:There is a 1 second timeout after print.There is a 1 second timeout after copy. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 1740i | Image Runner | Yes |
No |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A4-IR1133 | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A4-IR1133 Limitations:There is a 1 second timeout after print.There is a 1 second timeout after copy. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 1730i | Image Runner | Yes |
No |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A4-IR1133 | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A4-IR1133 Limitations:There is a 1 second timeout after print.There is a 1 second timeout after copy. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 1133iF | Image Runner | Yes |
No |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A4-IR1133 | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A4-IR1133 Limitations:There is a 1 second timeout after print.There is a 1 second timeout after copy. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 1133a | Image Runner | Yes |
No |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A4-IR1133 | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A4-IR1133 Limitations:There is a 1 second timeout after print.There is a 1 second timeout after copy. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 1133 | Image Runner | Yes |
No |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A4-IR1133 | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A4-IR1133 Limitations:There is a 1 second timeout after print.There is a 1 second timeout after copy. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 2570C | Image Runner | Yes |
Yes |
Yes |
Yes |
No |
CAFALSEN-iR3100C | No |
No |
Recommended driver:CAFALSEN-iR3100C Limitations:Counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 113 (A4 B/W) Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV 4051 | Image Runner Advance / iR ADV | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2520-V2 | No |
No |
Recommended driver:CAFALSEN-iR2520-V2 Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV 4045 | Image Runner Advance / iR ADV | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2520-V2 | No |
No |
Recommended driver:CAFALSEN-iR2520-V2 Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV 4035 | Image Runner Advance / iR ADV | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2520-V2 | No |
No |
Recommended driver:CAFALSEN-iR2520-V2 Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV 4025 | Image Runner Advance / iR ADV | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2520-V2 | No |
No |
Recommended driver:CAFALSEN-iR2520-V2 Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iRC 3580 | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iRC3580 | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iRC3580 Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iRC 2800 | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iRC3580 | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iRC3580 Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV 6075i | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-iR2520-V2 | No |
No |
Recommended driver:CAFALSEN-iR2520-V2 Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV 6065i | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-iR2520-V2 | No |
No |
Recommended driver:CAFALSEN-iR2520-V2 Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR ADV 6055i | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-iR2520-V2 | No |
No |
Recommended driver:CAFALSEN-iR2520-V2 Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR C3200 on EFI | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
No |
CAFALSEN-iR3100C | No |
No |
Recommended driver:CAFALSEN-iR3100C Limitations: Counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 113 (A4 B/W) Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR C3200 | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-iR3100C | No |
No |
Recommended driver:CAFALSEN-iR3100C Limitations:Counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 113 (A4 B/W) Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
J1317 connector is used for blocking
|
Canon | iRC 3220 | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-iRC2620 | No |
No |
Recommended driver:CAFALSEN-iRC2620 Limitation:Device state is detected over SNMP. Counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 113 (A4 B/W). Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iRC 2620 | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-iRC2620 | No |
No |
Recommended driver:CAFALSEN-iRC2620 Limitation:Device state is detected over SNMP. Counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 113 (A4 B/W). Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR-ADV C2230i | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-C22XX | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-C22XX Limitations:Counters for copy and print are shared.Session may be closed prematurely if calibration is in progress. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
YSQC0-047-0000 Blocking Cable (use connector J1026 on the main board) If you have a Kit-A1 available, use this cable: YSQC0-041-0000 - with Kit-A1 (Canon party extension)
|
Canon | iR-ADV C2225i | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-C22XX | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-C22XX Limitations:Counters for copy and print are shared.Session may be closed prematurely if calibration is in progress. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
YSQC0-047-0000 Blocking Cable (use connector J1026 on the main board) If you have a Kit-A1 available, use this cable: YSQC0-041-0000 - with Kit-A1 (Canon party extension)
|
Canon | iR-ADV C2220i | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-C22XX | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-C22XX Limitations:Counters for copy and print are shared.Session may be closed prematurely if calibration is in progress. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
YSQC0-047-0000 Blocking Cable (use connector J1026 on the main board) If you have a Kit-A1 available, use this cable: YSQC0-041-0000 - with Kit-A1 (Canon party extension)
|
Canon | iR ADV C5035i | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iRADVC | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iRADVC Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
YSQC0-047-0000 Blocking Cable (use connector J1026 on the main board) If you have a Kit-A1 available, use this cable: YSQC0-041-0000 - with Kit-A1 (Canon party extension)
|
Canon | iR ADV C5051i | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iRADVC | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iRADVC Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
YSQC0-047-0000 Blocking Cable (use connector J1026 on the main board) If you have a Kit-A1 available, use this cable: YSQC0-041-0000 - with Kit-A1 (Canon party extension)
|
Canon | iR ADV C5030i | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iRADVC | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iRADVC Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
YSQC0-047-0000 Blocking Cable (use connector J1026 on the main board) If you have a Kit-A1 available, use this cable: YSQC0-041-0000 - with Kit-A1 (Canon party extension)
|
Canon | iR ADV C2030i | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iRADVC | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iRADVC Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
YSQC0-047-0000 Blocking Cable (use connector J1026 on the main board) If you have a Kit-A1 available, use this cable: YSQC0-041-0000 - with Kit-A1 (Canon party extension)
|
Canon | iR ADV C2025i | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iRADVC | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iRADVC Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
YSQC0-047-0000 Blocking Cable (use connector J1026 on the main board) If you have a Kit-A1 available, use this cable: YSQC0-041-0000 - with Kit-A1 (Canon party extension)
|
Canon | iR ADV C2020i | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iRADVC | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iRADVC Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
YSQC0-047-0000 Blocking Cable (use connector J1026 on the main board) If you have a Kit-A1 available, use this cable: YSQC0-041-0000 - with Kit-A1 (Canon party extension)
|
Canon | iR ADV C5045i | Image Runner Advance / iR ADV | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-MFP-COL-A3-iRADVC | No |
No |
Recommended driver:CAFALSEN-MFP-COL-A3-iRADVC Limitations:Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
YSQC0-047-0000 Blocking Cable (use connector J1026 on the main board) If you have a Kit-A1 available, use this cable: YSQC0-041-0000 - with Kit-A1 (Canon party extension)
|
Canon | iRC 3100 | Image Runner | Yes |
Yes |
Yes |
Yes |
Yes |
CAFALSEN-iR3100C | No |
No |
Recommended driver:CAFALSEN-iR3100C Limitations:Counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 113 (A4 B/W) Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3245n | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR3245 | No |
No |
Recommended driver: CAFALSEN-MFP-BW-A3-iR3245 Limitations: Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3235n | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR3245 | No |
No |
Recommended driver: CAFALSEN-MFP-BW-A3-iR3245 Limitations: Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3225n | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR3245 | No |
No |
Recommended driver: CAFALSEN-MFP-BW-A3-iR3245 Limitations: Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3320N | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2200 | No |
No |
Recommended driver:CAFALSEN-iR2200 Limitations:Enhanced detection of device status. There is 5 seconds timeout after copy. Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3320i | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2200 | No |
No |
Recommended driver:CAFALSEN-iR2200 Limitations:Enhanced detection of device status. There is 5 seconds timeout after copy. Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3300EN | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2200 | No |
No |
Recommended driver:CAFALSEN-iR2200 Limitations:Enhanced detection of device status. There is 5 seconds timeout after copy. Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3300E | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2200 | No |
No |
Recommended driver:CAFALSEN-iR2200 Limitations:Enhanced detection of device status. There is 5 seconds timeout after copy. Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3300i | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2200 | No |
No |
Recommended driver:CAFALSEN-iR2200 Limitations:Enhanced detection of device status. There is 5 seconds timeout after copy. Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3300 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2200 | No |
No |
Recommended driver:CAFALSEN-iR2200 Limitations:Enhanced detection of device status. There is 5 seconds timeout after copy. Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 2800 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2200 | No |
No |
Recommended driver:CAFALSEN-iR2200 Limitations:Enhanced detection of device status. There is 5 seconds timeout after copy. Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 2220N | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2200 | No |
No |
Recommended driver:CAFALSEN-iR2200 Limitations:Enhanced detection of device status. There is 5 seconds timeout after copy. Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 2220i | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2200 | No |
No |
Recommended driver:CAFALSEN-iR2200 Limitations:Enhanced detection of device status. There is 5 seconds timeout after copy. Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 2200 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-iR2200 | No |
No |
Recommended driver:CAFALSEN-iR2200 Limitations:Enhanced detection of device status. There is 5 seconds timeout after copy. Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 4570 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW | No |
No |
Recommended driver:CAFALSEN-MFP-BW Limitations:Device state is detected over SNMP. counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 101. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3570 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW | No |
No |
Recommended driver:CAFALSEN-MFP-BW Limitations:Device state is detected over SNMP. counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 101. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3530 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW | No |
No |
Recommended driver:CAFALSEN-MFP-BW Limitations:Device state is detected over SNMP. counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 101. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3045 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW | No |
No |
Recommended driver:CAFALSEN-MFP-BW Limitations:Device state is detected over SNMP. counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 101. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3030 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW | No |
No |
Recommended driver:CAFALSEN-MFP-BW Limitations:Device state is detected over SNMP. counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 101. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 3025 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW | No |
No |
Recommended driver:CAFALSEN-MFP-BW Limitations:Device state is detected over SNMP. counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 101. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 2870 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW | No |
No |
Recommended driver:CAFALSEN-MFP-BW Limitations:Device state is detected over SNMP. counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 101. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 2830 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW | No |
No |
Recommended driver:CAFALSEN-MFP-BW Limitations:Device state is detected over SNMP. counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 101. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 2270 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW | No |
No |
Recommended driver:CAFALSEN-MFP-BW Limitations:Device state is detected over SNMP. counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 101. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 2230 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW | No |
No |
Recommended driver:CAFALSEN-MFP-BW Limitations:Device state is detected over SNMP. counters are read over HTTP. Counters for copy and print are shared. This driver is working with counters 101. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
|
Canon | iR 2545 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR2530-V3 | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A3-iR2530-V3 Limitations:There is a 2 seconds timeout after print.There is a 2 seconds timeout after copy.Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
Cable supports off-line accounting A3/A4 BW.
|
Canon | iR 2535 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR2530-V3 | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A3-iR2530-V3 Limitations:There is a 2 seconds timeout after print.There is a 2 seconds timeout after copy.Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
Cable supports off-line accounting A3/A4 BW.
|
Canon | iR 2530 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR2530-V3 | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A3-iR2530-V3 Limitations:There is a 2 seconds timeout after print.There is a 2 seconds timeout after copy.Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
Cable supports off-line accounting A3/A4 BW.
|
Canon | iR 2525 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR2530-V3 | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A3-iR2530-V3 Limitations:There is a 2 seconds timeout after print.There is a 2 seconds timeout after copy.Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
Cable supports off-line accounting A3/A4 BW.
|
Canon | iR 2520 | Image Runner | Yes |
Yes |
No |
Yes |
Yes |
CAFALSEN-MFP-BW-A3-iR2530-V3 | No |
No |
Recommended driver:CAFALSEN-MFP-BW-A3-iR2530-V3 Limitations:There is a 2 seconds timeout after print.There is a 2 seconds timeout after copy.Counters for copy and print are shared. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
Cable supports off-line accounting A3/A4 BW.
|
Canon | iR 1024iF | Image Runner | Yes |
No |
No |
Yes |
Yes |
CAFALSEN-iR1024 | No |
No |
Recommended driver:CAFALSEN-iR1024 Limitations:There is 5 seconds timeout after copy.There is 5 seconds timeout after print.Duplex copy is accounted as simplex.Duplex print is detected from print job parser. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
Possibility to scan to mail or scan to fax only
|
Canon | iR 1022iF | Image Runner | Yes |
No |
No |
Yes |
Yes |
CAFALSEN-iR1024 | No |
No |
Recommended driver:CAFALSEN-iR1024 Limitations:There is 5 seconds timeout after copy.There is 5 seconds timeout after print.Duplex copy is accounted as simplex.Duplex print is detected from print job parser. Post script license is required for YSoft Mobile print server. | No |
Untested |
No |
No |
No |
No |
Possibility to scan to mail or scan to fax only
|
Canon | imageRUNNER ADVANCE DX 6800 | Yes |
Yes |
No |
Yes |
No |
No |
Yes |
No |
Untested |
No |
Yes |
No |
No |
||||
Canon | imageRUNNER ADVANCE DX C5800 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Untested |
No |
Yes |
No |
No |
||||
Canon | imageRUNNER ADVANCE DX C478 | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Untested |
No |
Yes |
No |
No |
||||
Dell | 3100cn | Dell | No |
No |
No |
Yes |
Yes |
DELL-PRN-BW-A4 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
|
Dell | 2335dn | Dell | Yes |
No |
No |
Yes |
Yes |
DELL-MFP-BW-A4-DUP | No |
No |
Recommended driver:DELL-MFP-BW-A4-DUP Limitations:Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
no blocking available
|
Dell | 5330dn | Dell | No |
No |
No |
Yes |
Yes |
DELL-PRN-BW-A4 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
|
Dell | 5110cn | Dell | No |
No |
Yes |
Yes |
Yes |
DELL-PRN-COL-A4 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
|
Dell | 3115cn | Dell | Yes |
No |
Yes |
Yes |
Yes |
DELL-MFP-COL-A4-3115 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
|
Dell | 2330dn | Dell | No |
No |
No |
Yes |
Yes |
DELL-PRN-BW-A4-2330 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
|
Dell | 2135dn | Dell | Yes |
No |
Yes |
Yes |
Yes |
DELL-MFP-COL-A4-2135 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
|
Develop | ineo 658e | ineo | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Develop | ineo 558e | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
||||
Develop | ineo 458e | ineo | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Develop | ineo 308e, 368e | ineo | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Develop | ineo+ 3320i | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Common for SafeQ5 and SafeQ6(MFD limitation with the tested FW version)
MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. This bug will be fixed by IT6v2.0 mass-production FW that is scheduled for release in early October. Classic UI does not have this issue.
When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0 which are not enabled by default on the device. To use TLS1.1 or TLS1.2, set kmOpenApiVersion to 4-13a(default of SafeQ6).
When using SafeQ6 Gen2 terminal, certificate validation shall be disabled in the MFD or the MFD loops the certificate validation message on the browser on logout attempt. Or the solution is to create a custom certificate having SAN(Subject Alternative Name) and use it instead and register to bizhub. Termianl server default certificate does not have SAN value and cannot be trusted so the behavior above occurs.
SafeQ5
(Native TE only) Auto logout by user defined timeout does not work.
(Browser TE) Auto logout by user defined time out only logges out a user from the SQ application. A user needs to press MFD's logout button to logout. System Auto Reset shall be used instead for auto logout.
Logout by card requires DIP SW value change.
SafeQ6
(Native TE only) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Gen2 browser) Certificate validation shall be disabled or the MFD loops showing certificate validation message and behaves strangely when trying to logout. Registering a certificate from the MFD's browser cannot register the cert. Uploading a cert from the administration web also does not solve this behavior
Logout by card requires DIP SW value change.
|
|||
Develop | ineo 4752 | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
||||
Develop | ineo 4052 | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
||||
Develop | ineo+ 750i | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
||||
Develop | ineo+ 286 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Untested |
No |
No |
No |
No |
||||
Develop | ineo+ 256 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Untested |
No |
No |
No |
No |
||||
Develop | Ineo 213 | Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
Untested |
No |
No |
No |
No |
||||
Develop | Ineo 163 | Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
Untested |
No |
No |
No |
No |
||||
Develop | ineo+ 4050i | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A4-C3350i | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A4-C3350i Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. | Yes |
Yes |
No |
No |
Yes |
Yes |
Common Limitations:
MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. Classic UI does not have this issue.
SafeQ5
Logout by card does not work.
|
|
Develop | ineo+ 3350i | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A4-C3350i | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A4-C3350i Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. | Yes |
Yes |
No |
No |
Yes |
Yes |
Common Limitations:
MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. Classic UI does not have this issue.
SafeQ 5
Logout by card does not work.
|
|
Develop | ineo+ 360i | ineo+ | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3 / MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested Controler ROM version
AA2J0Y0-0100-G00-23(00)
Common for SafeQ5 and SafeQ6(MFD limitation with the tested FW version)
MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. This bug will be fixed by IT6v2.0 mass-production FW that is scheduled for release in early October. Classic UI does not have this issue.
When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a.
When using SafeQ6 Gen2 terminal, certificate validation shall be disabled in the MFD or the MFD loops the certificate validation message on the browser on logout attempt. Or the solution is to create a custom certificate having SAN(Subject Alternative Name) and use it instead and register to bizhub. Termianl server default certificate does not have SAN value and cannot be trusted so the behavior above occurs.
SafeQ5
(Native TE only) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Browser TE) Auto logout by user defined time out only logges out a user from the SQ application. A user needs to pres MFD's logout button to logout.
Logout by card requires DIP SW value change. Please ask KM internally for DIP SW value.
SafeQ6
(Native TE only) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Gen2 browser) Certificate validation shall be disabled or the MFD loops showing certificate validation message and behaves strangely when trying to logout. Registering a certificate from the MFD's browser cannot register the cert. Uploading a cert from the administration web also does not solve this behavior
Logout by card requires DIP SW value change. Please ask KM internally for DIP SW value.
|
Develop | ineo+ 300i | ineo+ | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3 / MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested Controler ROM version
AA2J0Y0-0100-G00-23(00)
Common for SafeQ5 and SafeQ6(MFD limitation with the tested FW version)
MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. This bug will be fixed by IT6v2.0 mass-production FW that is scheduled for release in early October. Classic UI does not have this issue.
When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a.
When using SafeQ6 Gen2 terminal, certificate validation shall be disabled in the MFD or the MFD loops the certificate validation message on the browser on logout attempt. Or the solution is to create a custom certificate having SAN(Subject Alternative Name) and use it instead and register to bizhub. Termianl server default certificate does not have SAN value and cannot be trusted so the behavior above occurs.
SafeQ5
(Native TE only) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Browser TE) Auto logout by user defined time out only logges out a user from the SQ application. A user needs to pres MFD's logout button to logout.
Logout by card requires DIP SW value change. Please ask KM internally for DIP SW value.
SafeQ6
(Native TE only) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Gen2 browser) Certificate validation shall be disabled or the MFD loops showing certificate validation message and behaves strangely when trying to logout. Registering a certificate from the MFD's browser cannot register the cert. Uploading a cert from the administration web also does not solve this behavior
Logout by card requires DIP SW value change. Please ask KM internally for DIP SW value.
|
Develop | ineo+ 250i | ineo+ | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3 / MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version
AA2J0Y0-0100-G00-23(00)
Common for SafeQ5 and SafeQ6(MFD limitation with the tested FW version)
MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. This bug will be fixed by IT6v2.0 mass-production FW that is scheduled for release in early October. Classic UI does not have this issue.
When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a.
When using SafeQ6 Gen2 terminal, certificate validation shall be disabled in the MFD or the MFD loops the certificate validation message on the browser on logout attempt. Or the solution is to create a custom certificate having SAN(Subject Alternative Name) and use it instead and register to bizhub. Termianl server default certificate does not have SAN value and cannot be trusted so the behavior above occurs.
SafeQ5
(Native TE only) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Browser TE) Auto logout by user defined time out only logges out a user from the SQ application. A user needs to pres MFD's logout button to logout.
Logout by card requires DIP SW value change. Please ask KM internally for DIP SW value.
SafeQ6
(Native TE only) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Gen2 browser) Certificate validation shall be disabled or the MFD loops showing certificate validation message and behaves strangely when trying to logout. Registering a certificate from the MFD's browser cannot register the cert. Uploading a cert from the administration web also does not solve this behavior
Logout by card requires DIP SW value change. Please ask KM internally for DIP SW value.
|
Develop | ineo+ 4000i | ineo+ | No |
No |
Yes |
Yes |
No |
MIFALSELTA-PRN-COL-A4-C3300 | Yes |
Yes |
Recommended driver: MIFALSELTA-PRN-COL-A4-C3300 Limitations: There is a 3 seconds timeout after print. Each 2 colors print is accounted as a full-color print. | Yes |
Yes |
No |
No |
Yes |
Yes |
Device has limited OpenAPI - Application icon is not visible, can be added manually via web interface of the device.
Minimum required firmware: GC1-73
Scan application is not supported.
|
Develop | ineo+ 3300i | No |
No |
Yes |
Yes |
No |
MIFALSELTA-PRN-COL-A4-C3300 | No |
Yes |
Recommended driver: MIFALSELTA-PRN-COL-A4-C3300 Limitations: There is a 3 seconds timeout after print. Each 2 colors print is accounted as a full-color print. | Yes |
Yes |
No |
No |
Yes |
Yes |
Device has limited OpenAPI - Application icon is not visible, can be added manually via web interface of the device.
Minimum required firmware: GC1-73
Scan application is not supported.
|
|
Develop | ineo+ 368 | ineo+ | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
Develop | ineo+ 308 | ineo+ | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
Develop | ineo+ 258 | ineo+ | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
Develop | ineo+ 3350 | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C3850 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-BIZHUB-C3850 Limitations: Required firmware for blocking: A3GN30G0206-999 or newer. | No |
Yes |
No |
No |
Yes |
Yes |
||
Develop | ineo+ 3850 | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C3850 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-BIZHUB-C3850 Limitations: Required firmware for blocking: A3GN30G0206-999 or newer. | No |
Yes |
No |
No |
Yes |
Yes |
||
Develop | Ineo 754e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. When blocked with Vender2 cable, online accounting does FALSEt work, machine is FALSEt increasing counters. This problem can be solved by using firmware version GD1-83 | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
|
|
Develop | Ineo 654e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. When blocked with Vender2 cable, online accounting does FALSEt work, machine is FALSEt increasing counters. This problem can be solved by using firmware version GD1-83 | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
|
|
Develop | Ineo 554e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE | No |
Yes |
Recommended driver:MIFALSELTA-MFP-BW-A3-XXXE Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information. | Yes |
Yes |
No |
No |
Yes |
No |
||
Develop | Ineo 454e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | No |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
|
|
Develop | Ineo 364e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
|
|
Develop | Ineo 284e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
|
|
Develop | Ineo 224e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
|
|
Develop | Ineo+ 754e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Develop | Ineo+ 654e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Develop | Ineo+ 554e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Develop | Ineo+ 454e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Develop | Ineo+ 364e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Develop | Ineo+ 284e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Develop | Ineo+ 224e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Develop | Ineo+ 754 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
Yes |
Native: HDD: 250GB, Memory: 2GB (already built in) Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Develop | Ineo+ 654 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
Yes |
Native: HDD: 250GB, Memory: 2GB (already built in) Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Develop | Ineo+ 554 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
Yes |
Native: HDD: 250GB and Memory: 2GB built in by default Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Develop | Ineo+ 454 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
Yes |
Native: HDD: 250GB and Memory: 2GB built in by default Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Develop | Ineo+ 364 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB and Memory: 2GB built in by default Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Develop | Ineo+ 284 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
Yes |
Native: HDD: 250GB and Memory: 2GB built in by default Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Develop | Ineo+ 224 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
Yes |
Native: HDD: 250GB and Memory: 2GB built in by default Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Develop | Ineo 754 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Develop | Ineo 654 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Develop | Ineo 423 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2 Limitations: There are 3 seconds timeouts after copy and print. Additional busy state recognition from number of active jobs. This driver is suitable for Mode2 accounting. Offline copy accounting enabled. A3 scan is accounted as 2xA4. Each scan is accounted also as a copy with 0 pages. Separate counters for print and copy. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Develop | Ineo 363 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2 Limitations: There are 3 seconds timeouts after copy and print. Additional busy state recognition from number of active jobs. This driver is suitable for Mode2 accounting. Offline copy accounting enabled. A3 scan is accounted as 2xA4. Each scan is accounted also as a copy with 0 pages. Separate counters for print and copy. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Develop | Ineo 283 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2 Limitations: There are 3 seconds timeouts after copy and print. Additional busy state recognition from number of active jobs. This driver is suitable for Mode2 accounting. Offline copy accounting enabled. A3 scan is accounted as 2xA4. Each scan is accounted also as a copy with 0 pages. Separate counters for print and copy. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Develop | Ineo 223 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2 Limitations: There are 3 seconds timeouts after copy and print. Additional busy state recognition from number of active jobs. This driver is suitable for Mode2 accounting. Offline copy accounting enabled. A3 scan is accounted as 2xA4. Each scan is accounted also as a copy with 0 pages. Separate counters for print and copy. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Develop | ineo+ 650i | ineo+ | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
firmware GC1-25 or newer recommended
|
||
Develop | ineo+ 550i | ineo+ | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
firmware GC1-25 or newer recommended
|
||
Develop | ineo+ 450i | ineo+ | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
firmware GC1-75 or newer recommended
|
||
Develop | ineo+ 2060 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Recommended firmware:
GM9-21 and newer
System auto reset is disabled by default, please contact your distributor for service menu configuration.
Authentication cache not yest tested for SafeQ 6 With internal controller IC-603.
Firmware GM9-21 and later supports Billing codes and Card self assignment.
RBE and Finishing options are not supported.
|
|||
Develop | ineo+ 2060L | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Recommended firmware:
GM9-21 and newer
System auto reset is disabled by default, please contact your distributor for service menu configuration.
Authentication cache not yest tested for SafeQ 6 With internal controller IC-603.
Firmware GM9-21 and later supports Billing codes and Card self assignment.
RBE and Finishing options are not supported.
|
|||
Develop | 1052 | Ineo | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-BH1052 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-BH1052 Limitations: Duplex print is accounted according to parser from job information. There is a 3 second timeout after print. There is a 3 second timeout after copy. Additional busy state recognition from number of active jobs. This driver is suitable for Mode1 accounting. | No |
Untested |
No |
Yes |
No |
Yes |
Billing code selection and card self-registration is not supported and ends with an error.
|
Develop | 1052e | Ineo | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-BH1052 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-BH1052 Limitations: Duplex print is accounted according to parser from job information. There is a 3 second timeout after print. There is a 3 second timeout after copy. Additional busy state recognition from number of active jobs. This driver is suitable for Mode1 accounting. | No |
Untested |
No |
Yes |
No |
Yes |
Billing code selection and card self-registration is not supported and ends with an error.
|
Develop | 1250 | Ineo | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-BH1052 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-BH1052 Limitations: Duplex print is accounted according to parser from job information. There is a 3 second timeout after print. There is a 3 second timeout after copy. Additional busy state recognition from number of active jobs. This driver is suitable for Mode1 accounting. | No |
Untested |
No |
Yes |
No |
Yes |
Billing code selection and card self-registration is not supported and ends with an error.
|
Develop | 1250e | Ineo | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-BH1052 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-BH1052 Limitations: Duplex print is accounted according to parser from job information. There is a 3 second timeout after print. There is a 3 second timeout after copy. Additional busy state recognition from number of active jobs. This driver is suitable for Mode1 accounting. | No |
Untested |
No |
Yes |
No |
Yes |
Billing code selection and card self-registration is not supported and ends with an error.
|
Develop | ineo+ 2070 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Recommended firmware:
GM9-21 and newer
System auto reset is disabled by default, please contact your distributor for service menu configuration.
Authentication cache not yest tested for SafeQ 6 With internal controller IC-603.
Firmware GM9-21 and later supports Billing codes and Card self assignment.
RBE and Finishing options are not supported.
|
|||
Develop | ineo+ 220 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
Yes |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
HDD: 250GB, Memory: 2GB
Native with MyPanel:
DD: 250GB Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel:
HDD: 250GB Memory: 3GB (extended memory UK-203) LK-101v2 iOption License Kit
Recommended latest FW for embedded terminal.
|
|
Develop | ineo+ 220 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
Yes |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
HDD: 250GB, Memory: 2GB
Native with MyPanel:
DD: 250GB Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel:
HDD: 250GB Memory: 3GB (extended memory UK-203) LK-101v2 iOption License Kit
Recommended latest FW for embedded terminal.
|
|
Develop | ineo+ 280 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
Yes |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
HDD: 250GB, Memory: 2GB
Native with MyPanel:
DD: 250GB Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel:
HDD: 250GB Memory: 3GB (extended memory UK-203) LK-101v2 iOption License Kit
Recommended latest FW for embedded terminal.
|
|
Develop | ineo+ 360 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
Yes |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
HDD: 250GB, Memory: 2GB
Native with MyPanel:
DD: 250GB Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel:
HDD: 250GB Memory: 3GB (extended memory UK-203) LK-101v2 iOption License Kit
Recommended latest FW for embedded terminal.
|
|
Develop | ineo+ 652 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
Scan Color auto detection not supported with Browser Embedded terminal.
|
|
Develop | ineo+ 552 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
Scan Color auto detection not supported with Browser Embedded terminal.
|
|
Develop | ineo+ 452 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
Scan Color auto detection not supported with Browser Embedded terminal.
|
|
Develop | ineo+ 1070 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to mode 2. | Yes |
Untested |
No |
No |
Yes |
Yes |
|
|
Develop | ineo+ 658 | ineo+ | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5: A79J0Y0-0100-G00-10
|
Develop | ineo+ 558 | ineo+ | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5: A79J0Y0-0100-G00-10
|
Develop | ineo+ 458 | ineo+ | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5:
A79J0Y0-0100-G00-10
|
Develop | ineo+ 3851FS | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C3850 | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-BIZHUB-C3850 | Yes |
Yes |
No |
No |
Yes |
Yes |
To use Scan Workflow of SafeQ6 on Native OpenAPI Terminal, use the FW: A92E0Y0-F000-G00-K8 or later.
The model has an issue with Authentication cache behavior for authentication from the panel. Being investigated by Konica Minolta
|
|
Develop | ineo+ 3851 | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C3850 | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-BIZHUB-C3850 | Yes |
Yes |
No |
No |
Yes |
Yes |
To use Scan Workflow of SafeQ6 on Native OpenAPI Terminal, use the FW: A92E0Y0-F000-G00-K8 or later.
The model has an issue with Authentication cache behavior for authentication from the panel. Being investigated by Konica Minolta
|
|
Develop | ineo+ 3351 | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C3850 | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-BIZHUB-C3850 | Yes |
Yes |
No |
No |
Yes |
Yes |
To use Scan Workflow of SafeQ6 on Native OpenAPI Terminal, use the FW: A92E0Y0-F000-G00-K8 or later.
The model has an issue with Authentication cache behavior for authentication from the panel. Being investigated by Konica Minolta
|
|
Develop | ineo 367 | Yes |
No |
No |
No |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Recommended latest firmware (above G00-24).
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
|
Develop | ineo 287 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Recommended latest firmware (above G00-24).
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
|
Develop | ineo 227 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Recommended latest firmware (above G00-24).
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
|
Develop | ineo 4050 | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 | No |
Yes |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 Limitations: There is 1 second timeout after copy and print. bizhub 4050: Required firmware for blocking: A6F730G0236-999 or newer. Revision of motherboard from serial number A6VF021006606 (valid only for Europe). bizhub 4750: Required firmware for blocking: A6F730G0236-999 or newer. Revision of motherboard from serial number A6VF021001836 (valid only for Europe). | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
Job details are not displayed with tested version of firmware.
Recommended firmware: A6F730G0236-999 or newer.
USB card reader: Required firmware: A6F730G0121-999 or newer.
Device cancels Job by going to sleep mode.
Browser:
Recommended firmware A6F730G0804-W51 or later.
Tested Controler ROM version: A6F730G0110-999
|
|
Develop | ineo 4750 | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 | No |
Yes |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 Limitations: There is 1 second timeout after copy and print. ineo 4050: Required firmware for blocking: A6F730G0236-999 or newer. Revision of motherboard from serial number A6VF021006606 (valid only for Europe). ineo 4750: Required firmware for blocking: A6F730G0236-999 or newer. Revision of motherboard from serial number A6VF021001836 (valid only for Europe). | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
Job details are not displayed with tested version of firmware.
Recommended firmware: A6F730G0236-999 or newer.
USB card reader: Required firmware: A6F730G0121-999 or newer.
Device cancels Job by going to sleep mode.
Browser:
Recommended firmware A6F730G0804-W51 or later.
Tested Controler ROM version: A6F730G0110-999
|
|
Develop | ineo 4700P | No |
No |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A4-BIZHUB-3300P | No |
Yes |
Recommended driver: MIFALSELTA-PRN-BW-A4-BIZHUB-3300P Limitations: Duplex print is accounted according to parser from job information. There is a 4 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
||
Develop | ineo 3300P | No |
No |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A4-BIZHUB-3300P | No |
Yes |
Recommended driver: MIFALSELTA-PRN-BW-A4-BIZHUB-3300P Limitations: Duplex print is accounted according to parser from job information. There is a 4 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
||
Develop | ineo 3301P | No |
No |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A4-BIZHUB-3300P | No |
Yes |
MIFALSELTA-PRN-BW-A4-BIZHUB-3300P Limitations: Duplex print is accounted according to parser from job information. There is a 4 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
||
Develop | ineo 4000p | No |
No |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A4-BIZHUB-3300P | No |
Yes |
MIFALSELTA-PRN-BW-A4-BIZHUB-3300P Limitations: Duplex print is accounted according to parser from job information. There is a 4 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
||
Develop | ineo 1100 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-BH1100 | No |
Yes |
MIFALSELTA-MFP-BW-A3-BH1100 Limitations: Additional busy state recognition from number of active jobs. This driver is suitable for Mode 1 accounting only. Device is FALSEt ready in sleep mode. Direct print is FALSEt possible when device is blocked by blocking cable. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
Self card assignment is not supported.
Accounting of scanning is supported from SafeQ 5 Maintenance Update 30.
User cannot log in when he has more than one billing code.
Payment System: User is able to scan without credit / Device do not block user with no credit while scanning.
Browser:
Not currently supported.
Tested Controler ROM version:
Controller P1: A7990Y0-00P1-G00-20
Controller P2: A799011-00P2-G00-10
|
|
Develop | ineo 958 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5: A7950Y0-0100-G00-17 (TE)
|
|
Develop | ineo 758 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5: A7950Y0-0100-G00-17 (TE)
|
|
Develop | ineo 308 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 | No |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. | Yes |
Yes |
No |
No |
Yes |
Yes |
||
Develop | ineo 368 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 | No |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. | Yes |
Yes |
No |
No |
Yes |
Yes |
||
Develop | ineo 458 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 | No |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. | Yes |
Yes |
No |
No |
Yes |
Yes |
||
Develop | ineo 558 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 | No |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. | Yes |
Yes |
No |
No |
Yes |
Yes |
||
Develop | ineo 4701i | ineo | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
LD Device since SAFEQ 6 Build 99. |
||
Develop | ineo+ 3301i | ineo+ | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
LD Device since SAFEQ 6 Build 99.
|
||
Develop | ineo 4050i, 4700i, 4750i | ineo | No |
No |
No |
Yes |
Yes |
MIFALSELTA-PRN-BW-A4-4700i | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
||
Develop | ineo 300i, 360i | ineo | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-XXXE-V3 / MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||
Develop | ineo 301i, 361i | ineo | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Develop | ineo 450i, 550i, 650i | ineo | Yes |
Yes |
No |
No |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 / MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||
Develop | ineo 451i, 551i, 651i | ineo | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Develop | ineo+ 3351i, 4001i, 4051i | ineo+ | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Develop | ineo+ 227, 287 | ineo+ | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||
Develop | ineo+ 451i, 551i, 651i | ineo+ | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Develop | ineo 4051i, 4751i | ineo | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Develop | ineo 750i | ineo | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 / MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||
Develop | ineo 751i | ineo | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Develop | ineo+ 227i, 257i, 287i | ineo+ | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||
Develop | ineo+ 251i, 301i, 361i | ineo+ | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Develop | ineo+ 659, 759 | ineo+ | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Develop | ineo+ 751i | ineo+ | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Epson | WF-M20590 | WorkForce Enterprise | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
It is not possible to access other menu once Print feature is blocked in Access Definition |
||
Epson | WF-M21000 | WorkForce Enterprise | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
It is not possible to access other menu once Print feature is blocked in Access Definition |
||
Epson | WF-C20750 | WorkForce Enterprise | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
It is not possible to access other menu once Print feature is blocked in Access Definition |
||
Epson | WF-C20600 | WorkForce Enterprise | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
It is not possible to access other menu once Print feature is blocked in Access Definition |
||
Epson | WF-C21000 | WorkForce Enterprise | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
It is not possible to access other menu once Print feature is blocked in Access Definition |
||
Epson | AM-C4000 | WorkForce Enterprise | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
It is not possible to access other menu once Print feature is blocked in Access Definition. |
||
Epson | AM-C5000 | WorkForce Enterprise | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
It is not possible to access other menu once Print feature is blocked in Access Definition. |
||
Epson | AM-C6000 | WorkForce Enterprise | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
It is not possible to access other menu once Print feature is blocked in Access Definition. |
||
Epson | WF-C879RRDWF | WorkForce Pro | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firmware required for Embedded terminal. |
||
Epson | WF-C878RDWF | WorkForce Pro | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firmware required for Embedded terminal. |
||
Epson | WF-C579R | WorkForce Pro | Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firmware required for Embedded terminal. |
||
Epson | WF-C8690DWF | WorkForce Pro | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firmware required for Embedded terminal. |
||
Epson | WorkForce Pro WF-8510 | Yes |
Yes |
Yes |
Yes |
No |
EPSON-MFP-COL-A3-WF8590 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Epson | WF-R8590 | WorkForce Pro | Yes |
Yes |
Yes |
Yes |
No |
EPSON-MFP-COL-A3-WF8590 | No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firmware required for Embedded terminal. |
|
Epson | WF-8590 | WorkForce Pro | Yes |
Yes |
Yes |
Yes |
No |
EPSON-MFP-COL-A3-WF8590 | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Epson Open Platform firmware required for Embedded terminal. |
|
Epson | WorkForce Pro WF-5620 | Yes |
No |
Yes |
Yes |
No |
EPSON-MFP-COL-A4-WF5690 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Epson | WF-R5690 | WorkForce Pro | Yes |
No |
Yes |
Yes |
No |
EPSON-MFP-COL-A4-WF5690 | No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firmware required for Embedded terminal. |
|
Epson | WF-5690DW | WorkForce Pro | Yes |
No |
Yes |
Yes |
No |
EPSON-MFP-COL-A4-WF5690 | No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firmware required for Embedded terminal. |
|
Epson | WorkForcePro WP-4025 | No |
No |
Yes |
Yes |
No |
EPSON-PRN-COL-A4-WP4025 | No |
No |
Recommended driver:EPSON-PRN-COL-A4-WP4025 Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
Epson | AcuLaser CX37DN | Yes |
No |
Yes |
Yes |
No |
EPSON-MFP-COL-DUP-CX37 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
||
Epson | AcuLaser M8000N | No |
Yes |
No |
Yes |
No |
EPSON-A3-AL-M8000 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
||
Epson | LP-V500 | No |
No |
No |
Yes |
No |
EPSON-PRN-COL-A4 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
||
Epson | AcuLaser MX21DN | Yes |
No |
Yes |
Yes |
No |
EPSON-MFP-BW-MX20 | No |
No |
Recommended driver:EPSON-MFP-BW-MX20 Limitations:Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
no blocking available
|
|
Epson | AcuLaser MX20DN | Yes |
No |
Yes |
Yes |
No |
EPSON-MFP-BW-MX20 | No |
No |
Recommended driver:EPSON-MFP-BW-MX20 Limitations:Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
no blocking available
|
|
Epson | AcuLaser M4000N | No |
No |
No |
Yes |
No |
EPSON-AL-M-4000 | No |
No |
Recommended driver:EPSON-AL-M-4000 Limitations:Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
no blocking available
|
|
Epson | AcuLaser M2410N | No |
No |
No |
Yes |
No |
EPSON-PRN-BW-2400 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
||
Epson | AcuLaser M2400N | No |
No |
No |
Yes |
No |
EPSON-PRN-BW-2400 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
||
Epson | AcuLaser M2310N | No |
No |
No |
Yes |
No |
EPSON-PRN-BW-2400 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
||
Epson | AcuLaser M2300N | No |
No |
No |
Yes |
No |
EPSON-PRN-BW-2400 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
||
Epson | AcuLaser CX29 | Yes |
No |
Yes |
Yes |
No |
EPSON-AL-CX29 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
||
Epson | AcuLaser C2900 | No |
No |
Yes |
Yes |
No |
EPSON-AL-C2900 | No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
||
Epson | M15180 | EcoTank Pro | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
It is not possible to access other menu once Print feature is blocked in Access Definition |
||
Epson | ET-M16680 | EcoTank | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
It is not possible to access other menu once Print feature is blocked in Access Definition |
||
Epson | L15180 | EcoTank Pro | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
It is not possible to access other menu once Print feature is blocked in Access Definition |
||
Epson | ET-16680 | EcoTank Pro | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
It is not possible to access other menu once Print feature is blocked in Access Definition |
||
Epson | WF-C5890 | WorkForce Pro | Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
It is not possible to access other menu once Print feature is blocked in Access Definition |
||
Epson | WF-M5799 | WorkForce Pro | Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firmware required for Embedded terminal. |
||
Epson | WF-C5790 | WorkForce Pro | Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firmware required for Embedded terminal. |
||
Epson | WF-C869R | WorkForce Pro | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firmware required for Embedded terminal. |
||
Epson | WF-6590 | WorkForce Pro | Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firware required for Embedded terminal.
|
||
Epson | WorkForce AL-M300DN Series | No |
No |
No |
Yes |
No |
No |
No |
Request: SAFEQ-33949 Offline accounting is supported.* All devices (incl. devices FALSEt covered by the list) are compatible with YSoft SafeQ offline accounting provided they support PCL, Post Script or HPGL print language. | No |
Untested |
No |
No |
No |
No |
|||
Epson | AcuLaser C1100 | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Epson | WorkForce AL-MX300DNF | Yes |
No |
No |
Yes |
No |
No |
No |
Request: YSOFT-2014-23339 Offline accounting is supported.* All devices (incl. devices FALSEt covered by the list) are compatible with YSoft SafeQ offline accounting provided they support PCL, Post Script or HPGL print language. | No |
Untested |
No |
No |
No |
No |
|||
Epson | WorkForce AL-M400DN | No |
No |
No |
Yes |
No |
No |
No |
Request: YSOFT-2014-16455 Offline accounting is supported.* All devices (incl. devices FALSEt covered by the list) are compatible with YSoft SafeQ offline accounting provided they support PCL, Post Script or HPGL print language. | No |
Untested |
No |
No |
No |
No |
|||
Epson | EPL-N4000+ | No |
No |
No |
Yes |
No |
No |
No |
Request: YSOFT-2014-15787 Offline accounting is supported.* All devices (incl. devices FALSEt covered by the list) are compatible with YSoft SafeQ offline accounting provided they support PCL, Post Script or HPGL print language. | No |
Untested |
No |
No |
No |
No |
|||
Epson | EPL-N3000 | No |
No |
No |
Yes |
No |
No |
No |
Request: YSOFT-2014-15787 Offline accounting is supported.* All devices (incl. devices FALSEt covered by the list) are compatible with YSoft SafeQ offline accounting provided they support PCL, Post Script or HPGL print language. | No |
Untested |
No |
No |
No |
No |
|||
Epson | WF-M5190 | WorkForce Pro | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Epson | WorkForcePro WP-4595DNF | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
|||
Epson | WorkForcePro WP-4525 | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
no blocking available
|
|||
Epson | WF-C17590 | WorkForce Enterprise | Yes |
Yes |
Yes |
Yes |
No |
EPSON-MFP-COL-A3-WF8590 | No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firmware required for Embedded terminal. |
|
Epson | WF-C20590 | WorkForce Enterprise | Yes |
Yes |
Yes |
Yes |
No |
EPSON-MFP-COL-A3-WF8590 | No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firmware required for Embedded terminal. |
|
Epson | WF-M5690 | WorkForce Pro | Yes |
No |
No |
Yes |
No |
EPSON-MFP-BW-A4-WFM5690 | No |
No |
Recommended driver: EPSON-MFP-BW-A4-WFM5690 Limitations: Counters for copy and print are shared. | Yes |
Yes |
No |
No |
No |
Yes |
Epson Open Platform firmware required for Embedded terminal. |
Epson | WF-5190 | WorkForce Pro | No |
No |
Yes |
Yes |
No |
EPSON-PRN-COL-A4-WF5190 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Epson | DS-900WN | WorkForce | No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
A4 color scanner only. Tested with firmware 09.30.NO09O4. |
||
Epson | AM-C400 | WorkForce Enterprise | Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Epson | AM-C550 | WorkForce Enterprise | Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Epson | EM-C800 | WorkForce Pro | Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Epson | WF-M5899DWF | WorkForce Pro | Yes |
No |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Epson | DS-800WN | WorkForce | No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
A4 color scanner only. |
||
Epson | EM-C7100 | WorkForce® Pro | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Fuji Xerox | ApeosPort-VII P4022 JM | ApeosPort-VII | No |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Information about the tested device(AIP6)
ApeosPort Print C4570
System: 20.6.17
Controller ROM: 1.5.3
IOT ROM: 72.6.0
Panel ROM: 240.109.18
Boot ROM: 1.0.80
SJFI: 5.0.0
SSMI: 2.104.0
Contents: 4.9.5
Plugin: 4.9.3
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII 5022 | ApeosPort-VII | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort Print C4570
System: 20.6.17
Controller ROM: 1.5.3
IOT ROM: 72.6.0
Panel ROM: 240.109.18
Boot ROM: 1.0.80
SJFI: 5.0.0
SSMI: 2.104.0
Contents: 4.9.5
Plugin: 4.9.3
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII C3322 | ApeosPort-VII | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII C4422 | ApeosPort-VII | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort 1860 | ApeosPort | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort C2360 | ApeosPort | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort 3570 | ApeosPort | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort 4570 | ApeosPort | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort 5570 | ApeosPort | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort C2570 | ApeosPort | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
Information about the tested device(AIP7)
Not yet tested
General
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
TE using AIP6(MU29 ~ MU75) - XCP Terminal requires SafeQ6 MU29 or newer.
TE using AIP6(MU76 and newer) - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
TE using AIP7(MU76 and newer) - Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
TE using AIP7(MU76 and newer) - Requires latest FW that supoprts AIP7 loaded to MFP. Only XCP Platform version 2.2.0 and higher supported.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | P475 AP | DocuPrint | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | ApeosPort-VII P4022 | ApeosPort-VII | No |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort Print C4570
System: 20.6.17
Controller ROM: 1.5.3
IOT ROM: 72.6.0
Panel ROM: 240.109.18
Boot ROM: 1.0.80
SJFI: 5.0.0
SSMI: 2.104.0
Contents: 4.9.5
Plugin: 4.9.3
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort 2560 | ApeosPort | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort 3060 | ApeosPort | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort 3560 | ApeosPort | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort C2060 | ApeosPort | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort C3060 | ApeosPort | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort C3070 | ApeosPort | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort C3570 | ApeosPort | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | Versant™ 180 Press | Production | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW Versant 180(Tested for Non-XCP with EPA reader only):
Controller ROM: 1.3.13
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: No
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on Versant models.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
A device with an optional print controllers - GX, GXI, EX, EX-i, FreeFlow are not suported.
|
||
Fuji Xerox | ApeosPort-VI C2271 | ApeosPort-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VI C2271(APAC model):
Controller ROM: 1.1.11
SJFI: 3.10.0
SSMI: 1.26.1
Plugin: 1.1.5
General
USB Card reader can be used in combination with XCP plugin terminal.
EPA Card reader can be used in combination with native terminal with Authentication Agent.
EPA interface has not been supported from ApeosPort-VI(2016) for 3rd party partners by Fuji Xerox. The device has EPA connector on the back panel, however the EPA interface operation is not guarantee by Fuji Xerox. So correct functioning of the EPA card reader is not guaranteed.
Copying
For XCP terminal to restrict Full Color copy by SafeQ user Access Right, the setting bellow shall be applied to the device.
Log in to the device as Administrator -> tools -> Authentication/Security Settings -> Authentication -> Access Control -> Feature access -> Color Copying (change it to Locked) -> Save -> Navigate out of all settings and reboot the device.
Scanning
SafeQ5
Workflow scan does not support XDW format.
SafeQ6
Workflow scan does not support XPS and XDW format.
Common
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black).
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-VII CP4422 | ApeosPort-VII | No |
No |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-A4-DUP | Yes |
Yes |
There is a 3 seconds timeout after print. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort Print C4570
System: 20.6.17
Controller ROM: 1.5.3
IOT ROM: 72.6.0
Panel ROM: 240.109.18
Boot ROM: 1.0.80
SJFI: 5.0.0
SSMI: 2.104.0
Contents: 4.9.5
Plugin: 4.9.3
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | M385 z | DocuPrint | Yes |
No |
No |
Yes |
No |
FUJI-XEROX-MFP-BW-DPM385 | No |
No |
Status detection based on display messages is supported for English only. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | P388 dw | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-PRN-BW-DPP375 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | P385 dw | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-PRN-BW-DPP375 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | ApeosPort Print C4570 | ApeosPort Print | No |
Yes |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-A4-DUP | Yes |
Yes |
There is a 3 seconds timeout after print. ApeosPort Print C4570 does FALSEt have the Large paper size counter and A3 is accounted as A4. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort Print C4570
System: 20.6.17
Controller ROM: 1.5.3
IOT ROM: 72.6.0
Panel ROM: 240.109.18
Boot ROM: 1.0.80
SJFI: 5.0.0
SSMI: 2.104.0
Contents: 4.9.5
Plugin: 4.9.3
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | CP475 AP | DocuPrint | No |
No |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-A4-DUP | No |
No |
There is a 3 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-VII CP3322 | ApeosPort-VII | No |
No |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-A4-DUP | Yes |
Yes |
There is a 3 seconds timeout after print. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort Print C4570
System: 20.6.17
Controller ROM: 1.5.3
IOT ROM: 72.6.0
Panel ROM: 240.109.18
Boot ROM: 1.0.80
SJFI: 5.0.0
SSMI: 2.104.0
Contents: 4.9.5
Plugin: 4.9.3
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-VII CP4421 | ApeosPort-VII | No |
No |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-A4-DUP | Yes |
Yes |
There is a 3 seconds timeout after print. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort Print C4570
System: 20.6.17
Controller ROM: 1.5.3
IOT ROM: 72.6.0
Panel ROM: 240.109.18
Boot ROM: 1.0.80
SJFI: 5.0.0
SSMI: 2.104.0
Contents: 4.9.5
Plugin: 4.9.3
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort Print C5570 | ApeosPort Print | No |
Yes |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-A4-DUP | Yes |
Yes |
There is a 3 seconds timeout after print. ApeosPort Print C4570 does FALSEt have the Large paper size counter and A3 is accounted as A4. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort Print C4570
System: 20.6.17
Controller ROM: 1.5.3
IOT ROM: 72.6.0
Panel ROM: 240.109.18
Boot ROM: 1.0.80
SJFI: 5.0.0
SSMI: 2.104.0
Contents: 4.9.5
Plugin: 4.9.3
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | DocuPrint C5155 d | DocuPrint | No |
Yes |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-A3 | No |
No |
There is a 3 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | DocuCentre-VI C7771 | DocuCentre-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | DocuCentre-VI C6671 | DocuCentre-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | DocuCentre-VI C5571 | DocuCentre-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | DocuCentre-VI C4471 | DocuCentre-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | DocuCentre-VI C3371 | DocuCentre-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | C3370 | DocuCentre-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | DocuCentre-C2271 | DocuCentre-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | DocuPrint 4408 d | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-PRN-BW-DP-3205D | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | DocuPrint 3508 d | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-PRN-BW-DP-3205D | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | DocuPrint 3208 d | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-PRN-BW-DP-3205D | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | DocuPrint 4405 d | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-PRN-BW-DP-3205D | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | DocuPrint 3505 d | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-PRN-BW-DP-3205D | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | DocuPrint 3205 d | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-PRN-BW-DP-3205D | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | Docu Centre V C3374 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
Tested FW C2276:
Controller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | C3055 DX | DocuPrint | No |
Yes |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-DP-C3055DX | No |
No |
Recommended driver:FUJI-XEROX-PRN-COL-DP-C3055DX Limitations: A3 is accounted as 1 x A4 Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | P355d | DocuPrint | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | M455df | DocuPrint | Yes |
No |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DP-M355DF | No |
No |
Recommended driver: FUJI-XEROX-MFP-DP-M355DF Limitations: Duplex copy is accounted as simplex. uplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | M355df | DocuPrint | Yes |
No |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DP-M355DF | No |
No |
Recommended driver: FUJI-XEROX-MFP-DP-M355DF Limitations: Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. LD device from YSoft SafeQ 6 MU22. | No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 MU22.
|
Fuji Xerox | C5005d | DocuPrint | No |
No |
Yes |
Yes |
No |
FUJI-XEROX-COL-A3-DUP-DP-C5005D | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | P455d | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-DP-P455D | No |
No |
LD device from YSoft SafeQ 6 MU22. | No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 MU22.
|
Fuji Xerox | CM405df | DocuPrint | Yes |
No |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DP-CM405DF | No |
No |
Recommended driver:FUJI-XEROX-MFP-COL-DP-CM405DFLimitations: Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | CP405d | DocuPrint | No |
No |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-DP-CP405D | No |
No |
Recommended driver:FUJI-XEROX-PRN-COL-DP-CP405D Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | CM505da | DocuPrint | Yes |
No |
Yes |
Yes |
Yes |
FUJI-XEROX-MPF-COL-DUP-DP-CM505DA | No |
No |
Recommended driver: FUJI-XEROX-MPF-COL-DUP-DP-CM505DA | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | CM305df | DocuPrint | Yes |
No |
Yes |
Yes |
No |
FUJI-XEROX-MFP-COL-DP-CM305DF | No |
No |
Recommended driver:FUJI-XEROX-MFP-COL-DP-CM305DFLimitations: Duplex copy is accounted as simplex. Duplex print is detected by parser. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | 2065 | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-2065 | No |
No |
Recommended driver:FUJI-XEROX-2065 Limitations: Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Same as Xerox WorkCentre M20i
|
Fuji Xerox | 45 | WorkCentre Pro | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | 50 | WorkCentre Pro | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | Docu Centre 9000 | Docu Centre | Yes |
Yes |
No |
Yes |
No |
FUJI-XEROX-MFP-DUP-DC-9000 | No |
No |
Recommended driver:FUJI-XEROX-MFP-DUP-DC-9000Limitations: There are 1 second timeouts after print and after copy. Each A3 page is accounted as A4 page. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort C5540I | ApeosPort | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | ApeosPort C6550I | ApeosPort | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | ApeosPort 7550I | ApeosPort | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | Docu Centre II 6000 | Docu Centre II | No |
No |
No |
Yes |
No |
FUJI-XEROX-MFP-A3-DUP-DC-6000 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | Docu Centre III 7000 | Docu Centre III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre III 6000 | Docu Centre III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre III 5000 | Docu Centre III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre III 4000 | Docu Centre III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre III 3010 | Docu Centre III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre III 3007 | Docu Centre III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre III 3005 | Docu Centre III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre III 3000 | Docu Centre III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre III 2007 | Docu Centre III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre III 2000 | Docu Centre III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | 4127 Copier & Printer | 41x | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3Limtations: There is 2 seconds timeout after print. Driver is using separated duplex counters. Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | 4112 Copier & Printer | 41x | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3Limtations: There is 2 seconds timeout after print. Driver is using separated duplex counters. Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort 750I | ApeosPort | Yes |
Yes |
No |
Yes |
Yes |
XEROX-MFP-BW-A3-5222 | No |
No |
Recommended driver: XEROX-MFP-BW-A3-5222 Limitations: There is a 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort 650I | ApeosPort | Yes |
Yes |
No |
Yes |
Yes |
XEROX-MFP-BW-A3-5222 | No |
No |
Recommended driver: XEROX-MFP-BW-A3-5222 Limitations: There is a 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort 550I | ApeosPort | Yes |
Yes |
No |
Yes |
Yes |
XEROX-MFP-BW-A3-5222 | No |
No |
Recommended driver: XEROX-MFP-BW-A3-5222 Limitations: There is a 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort 450I | ApeosPort | Yes |
Yes |
No |
Yes |
Yes |
XEROX-MFP-BW-A3-5222 | No |
No |
Recommended driver: XEROX-MFP-BW-A3-5222 Limitations: There is a 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort 350I | ApeosPort | Yes |
Yes |
No |
Yes |
Yes |
XEROX-MFP-BW-A3-5222 | No |
No |
Recommended driver: XEROX-MFP-BW-A3-5222 Limitations: There is a 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-II 7000 | ApeosPort-II | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-II 6000 | ApeosPort-II | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-II 5000 | ApeosPort-II | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-II 5010 | ApeosPort-II | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-II 4000 | ApeosPort-II | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-II 3000 | ApeosPort-II | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-3005 | No |
No |
Recommended driver:FUJI-XEROX-MFP-BW-A3-3005 Limitations: There is 1 second timeout after print. Printed/copied A3 prints/copies are accounted as A4 prints (1xA3 = 1xA4). Because of only one duplex counter for A3 and A4. A3 copies/prints are prioritized. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-II C4300 | ApeosPort-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver:FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP-V2 (for controller ROM version 1.42.xx or newer)FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP (for controller ROM version 1.41.xx or older) Limitations: There is a 1 second timeout after print. There is a 1 second timeout after copy. Each A3 page is accounted as A4 page. Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-II C3300 | ApeosPort-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver:FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP-V2 (for controller ROM version 1.42.xx or newer)FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP (for controller ROM version 1.41.xx or older) Limitations: There is a 1 second timeout after print. There is a 1 second timeout after copy. Each A3 page is accounted as A4 page. Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-II 2200 | ApeosPort-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver:FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP-V2 (for controller ROM version 1.42.xx or newer)FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP (for controller ROM version 1.41.xx or older) Limitations: There is a 1 second timeout after print. There is a 1 second timeout after copy. Each A3 page is accounted as A4 page. Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-II C7500 | ApeosPort-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver:FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP-V2 (for controller ROM version 1.42.xx or newer)FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP (for controller ROM version 1.41.xx or older) Limitations: There is a 1 second timeout after print. There is a 1 second timeout after copy. Each A3 page is accounted as A4 page. Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-II C6500 | ApeosPort-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver:FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP-V2 (for controller ROM version 1.42.xx or newer)FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP (for controller ROM version 1.41.xx or older) Limitations: There is a 1 second timeout after print. There is a 1 second timeout after copy. Each A3 page is accounted as A4 page. Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-II C5400 | ApeosPort-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver:FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP-V2 (for controller ROM version 1.42.xx or newer)FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP (for controller ROM version 1.41.xx or older) Limitations: There is a 1 second timeout after print. There is a 1 second timeout after copy. Each A3 page is accounted as A4 page. Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-III C7600 | ApeosPort-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-III C6500 | ApeosPort-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-III C5500 | ApeosPort-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-III C4400 | ApeosPort-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | D95 Printer | Production | Yes |
Yes |
No |
Yes |
No |
FUJI-XEROX-MFP-BW-A3-D110 | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-D110Limitations: There is a 2 seconds timeout after print. There is a 2 seconds timeout after copy. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | C4430 | DocuCenter-IV | Yes |
No |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APIV-C4430-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APIV-C4430-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre IV 5070 | Docu Centre IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-JPLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Each A3 page is accounted as A4 page. When Offline copy accounting is used, each A3 page is accounted as two A4 pages. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre IV 4070 | Docu Centre IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-JPLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Each A3 page is accounted as A4 page. When Offline copy accounting is used, each A3 page is accounted as two A4 pages. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | 7080 | DocuCenter-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | 6080 | DocuCenter-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | 5080 | DocuCenter-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | 3065 | DocuCenter-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | 3060 | DocuCenter-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | 2060 | DocuCenter-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C7780 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C6680 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C5580 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C7775 T2 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C7775 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C6675 T2 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C6675 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C5575 T2 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C5575 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C4475 T2 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C4475 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C3375 T2 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C3375 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C3373 T2 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C3373 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C2275 T2 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C2275 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C5570 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C4470 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C3371 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C3370 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C2270 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C2265 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C2263 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C2260 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V 5070 | Docu Centre V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-JPLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Each A3 page is accounted as A4 page. When Offline copy accounting is used, each A3 page is accounted as two A4 pages. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V 4070 | Docu Centre V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-JPLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Each A3 page is accounted as A4 page. When Offline copy accounting is used, each A3 page is accounted as two A4 pages. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V 7080 | Docu Centre V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V 6080 | Docu Centre V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | D95 Light Publisher | Production | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Untested |
No |
No |
Yes |
No |
Tested FW: D125=1.104.12
|
||
Fuji Xerox | D110 | Production | Yes |
Yes |
No |
Yes |
No |
FUJI-XEROX-MFP-BW-A3-D110 | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-D110Limitations: There is a 2 seconds timeout after print. There is a 2 seconds timeout after copy. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | D125 | Production | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Untested |
No |
No |
Yes |
No |
Tested FW: D125=1.104.12
|
||
Fuji Xerox | ApeosPort-IV C5570 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW C4470(Tested for Non-XCP with EPA reader only):
Controller ROM: 1.120.14
SJFI: 3.0.18
SSMI: 1.16.0
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: No
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV C4470 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW C4470(Tested for Non-XCP with EPA reader only):
Controller ROM: 1.120.14
SJFI: 3.0.18
SSMI: 1.16.0
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: No
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV C3371 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
No |
|
Fuji Xerox | ApeosPort-IV C3370 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW C4470(Tested for Non-XCP with EPA reader only):
Controller ROM: 1.120.14
SJFI: 3.0.18
SSMI: 1.16.0
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: No
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV C2270 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW C4470(Tested for Non-XCP with EPA reader only):
Controller ROM: 1.120.14
SJFI: 3.0.18
SSMI: 1.16.0
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: No
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV C4430 | ApeosPort-IV | Yes |
No |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APIV-C4430-APO | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
|
Fuji Xerox | ApeosPort-IV C7780 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW = 1.104.28
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
|
Fuji Xerox | ApeosPort-IV C6680 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
|
Fuji Xerox | ApeosPort-IV C5580 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
|
Fuji Xerox | ApeosPort-IV 5070 | ApeosPort-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Each A3 page is accounted as A4 page. When Offline copy accounting is used, each A3 page is accounted as two A4 pages. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW 4070(Non XCP terminal with EPA card reader only was tested):
Controller ROM: 1.120.14
SJFI: 3.0.18
SSMI: 1.16.0
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: No
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV 4070 | ApeosPort-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Each A3 page is accounted as A4 page. When Offline copy accounting is used, each A3 page is accounted as two A4 pages. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW 4070(Non XCP terminal with EPA card reader only was tested):
Controller ROM: 1.120.14
SJFI: 3.0.18
SSMI: 1.16.0
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: No
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV 3070 | ApeosPort-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Each A3 page is accounted as A4 page. When Offline copy accounting is used, each A3 page is accounted as two A4 pages. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW 4070(Non XCP terminal with EPA card reader only was tested):
Controller ROM: 1.120.14
SJFI: 3.0.18
SSMI: 1.16.0
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: No
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV 3065 | ApeosPort-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW 3065(Tested for Non-XCP with EPA reader only):
Controller ROM: 1.131.10
SJFI: 3.3.0
SSMI: 1.20.1
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: No
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal and USB interface Card reader are not supported on ApeosPort-IV generation 1 models with XCP version older than 1.2.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV 3060 | ApeosPort-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW 3065(Tested for Non-XCP with EPA reader only):
Controller ROM: 1.131.10
SJFI: 3.3.0
SSMI: 1.20.1
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: No
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal and USB interface Card reader are not supported on ApeosPort-IV generation 1 models with XCP version older than 1.2.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV 2060 | ApeosPort-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW 3065(Tested for Non-XCP with EPA reader only):
Controller ROM: 1.131.10
SJFI: 3.3.0
SSMI: 1.20.1
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: No
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal and USB interface Card reader are not supported on ApeosPort-IV generation 1 models with XCP version older than 1.2.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV 7080 | ApeosPort-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW: 6080=1.101.9, 7080=1.101.9
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
|
Fuji Xerox | ApeosPort-IV 6080 | ApeosPort-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW: 6080=1.101.9, 7080=1.101.9
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
|
Fuji Xerox | ApeosPort-IV C5575 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C2275
Controller ROM: 1.131.5
SJFI: 3.3.0
SSMI: 1.20.1
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal and USB interface Card reader are not supported on ApeosPort-IV generation 1 models with XCP version older than 1.2.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV C4475 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C2275
Controller ROM: 1.131.5
SJFI: 3.3.0
SSMI: 1.20.1
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal and USB interface Card reader are not supported on ApeosPort-IV generation 1 models with XCP version older than 1.2.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV C3375 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C2275
Controller ROM: 1.131.5
SJFI: 3.3.0
SSMI: 1.20.1
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal and USB interface Card reader are not supported on ApeosPort-IV generation 1 models with XCP version older than 1.2.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV C3373 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C2275:
Controller ROM: 1.131.5
SJFI: 3.3.0
SSMI: 1.20.1
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal and USB interface Card reader are not supported on ApeosPort-IV generation 1 models with XCP version older than 1.2.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-IV C2275 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C2275:
Controller ROM: 1.131.5
SJFI: 3.3.0
SSMI: 1.20.1
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal and USB interface Card reader are not supported on ApeosPort-IV generation 1 models with XCP version older than 1.2.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V C7780 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW version C5580:
Controller ROM: 1.3.7
SJFI: Version 3.5.0
SSMI: Version 1.21.0
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V C7775 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V C6680 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW version C5580:
Controller ROM: 1.3.7
SJFI: Version 3.5.0
SSMI: Version 1.21.0
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black).
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V C6675 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V C5580 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW version C5580:
Controller ROM: 1.3.7
SJFI: Version 3.5.0
SSMI: Version 1.21.0
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V C5575 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V C4475 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V 3375 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V C3373 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
|
Fuji Xerox | ApeosPort-V C2275 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V C7780 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C5580
Controller ROM: 1.3.7
SJFI: Version 3.5.0
SSMI: Version 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V C7775 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V C6680 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C5580
Controller ROM: 1.3.7
SJFI: Version 3.5.0
SSMI: Version 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V C6675 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V C5580 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C5580
Controller ROM: 1.3.7
SJFI: Version 3.5.0
SSMI: Version 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V C5575 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V C4475 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V C3375 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V C3373 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
SafeQ5 XCP terminal tested with the FW version 2.1.1
USB readers:
USB reader for AIP6 XCP terminal
EPA reader for AIP5 terminal & SafeQ4
Current version of SafeQ6 have certain limitations and defects under work. Contact Y Soft for detail.
|
Fuji Xerox | ApeosPort-V C2275 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V 4020 | ApeosPort-V | Yes |
No |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Each A3 page is accounted as A4 page. When Offline copy accounting is used, each A3 page is accounted as two A4 pages. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
DocuPrint M465 AP requirs optional External Access Kit to run Terminal Embedded
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is supported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | DocuPrint M465 AP | ApeosPort-V | Yes |
No |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver:FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Each A3 page is accounted as A4 page. When Offline copy accounting is used, each A3 page is accounted as two A4 pages. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
DocuPrint M465 AP requirs optional External Access Kit to run Terminal Embedded
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is supported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V C3320 | ApeosPort-V | Yes |
No |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW: CM415AP
Controller ROM: 1.2.7
SJFI: 3.7.1
SJFI: 3.7.1
Tested FW: C3320
Controller ROM: 1.2.5
DocuPrint CM415 AP requirs optional External Access Kit to run Terminal Embedded
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is supported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | DocuPrint CM415 AP | ApeosPort-V | Yes |
No |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW: CM415AP
Controller ROM: 1.2.7
SJFI: 3.7.1
SJFI: 3.7.1
Tested FW: C3320
Controller ROM: 1.2.5
DocuPrint CM415 AP requirs optional External Access Kit to run Terminal Embedded
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is supported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V 5070 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Each A3 page is accounted as A4 page. When Offline copy accounting is used, each A3 page is accounted as two A4 pages. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW version 5070:
Controller ROM: 1.0.12
SJFI: Version 3.7.0
SSMI: Version 1.24.0
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V 4070 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Each A3 page is accounted as A4 page. When Offline copy accounting is used, each A3 page is accounted as two A4 pages. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW version 5070:
Controller ROM: 1.0.12
SJFI: Version 3.7.0
SSMI: Version 1.24.0
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is supported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V 7080 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW 6080:
Controller ROM: 1.0.16
SJFI: 3.7.2
SSMI: 1.24.2
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is supported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V 6080 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-APO Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW 6080:
Controller ROM: 1.0.16
SJFI: 3.7.2
SSMI: 1.24.2
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is supported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | Docu Centre V C7776 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C6676 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C5576 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C4476 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C3376 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | Docu Centre V C2276 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
Recommended driver:FUJI-XEROX-MFP-APDCV-CXXX5-APOLimitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-V C7776 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C2276:
Controller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V C6676 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C2276:
Controller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V C5576 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C2276:
Controller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V C4476 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C2276:
Controller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V C3376 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C2276:
Controller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-V C2276 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C2276:
Controller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | Versant 170i Press | Versant | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device
Versant 180i Press
System: 20.4.3
Controller ROM: 1.1.2
SJFI: 3.6.1
SSMI: 1.22.23
Plugin: 4.7.2
General
EPA interface is no longer supported by Fuji Xerox for the model, so EPA card reader is out of support.
SafeQ 5 is not tested.
Installation and uninstallation
SafeQ6
XCP Terminal requires SafeQ6 MU29 or newer.
Common
Install XCP Terminal requires the manual steps bellow.
Login to the device as System Administrator
Go to “System” -> “Plug-in Settings”
Toggle “Signature Verification when Adding/Updating” to disabled.
Print job accounting requires following setting
Copying
For XCP terminal to restrict Full Color copy by SafeQ user Access Right, the setting bellow shall be applied to the device.
Log in to the device as Administrator -> Device -> Authentication/Accounting -> Authentication/Security Settings -> Authentication -> Access Control -> Feature access -> Color Copying (change it to Locked) -> Press hardware Home button and reboot the device.
Scanning
Scan to 1/2 color using Scan workflow generates BW scan because 1/2 colors scan is not supported by the device.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | Versant 180i Press | Versant | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device
Versant 180i Press
System: 20.4.3
Controller ROM: 1.1.2
SJFI: 3.6.1
SSMI: 1.22.23
Plugin: 4.7.2
General
EPA interface is no longer supported by Fuji Xerox for the model, so EPA card reader is out of support.
SafeQ 5 is not tested.
Installation and uninstallation
SafeQ6
XCP Terminal requires SafeQ6 MU29 or newer.
Common
Install XCP Terminal requires the manual steps bellow.
Login to the device as System Administrator
Go to “System” -> “Plug-in Settings”
Toggle “Signature Verification when Adding/Updating” to disabled.
Print job accounting requires following setting
Copying
For XCP terminal to restrict Full Color copy by SafeQ user Access Right, the setting bellow shall be applied to the device.
Log in to the device as Administrator -> Device -> Authentication/Accounting -> Authentication/Security Settings -> Authentication -> Access Control -> Feature access -> Color Copying (change it to Locked) -> Press hardware Home button and reboot the device.
Scanning
Scan to 1/2 color using Scan workflow generates BW scan because 1/2 colors scan is not supported by the device.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
|
||
Fuji Xerox | ApeosPort C2560 | ApeosPort | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII P5021 | ApeosPort-VII | No |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort Print C4570
System: 20.6.17
Controller ROM: 1.5.3
IOT ROM: 72.6.0
Panel ROM: 240.109.18
Boot ROM: 1.0.80
SJFI: 5.0.0
SSMI: 2.104.0
Contents: 4.9.5
Plugin: 4.9.3
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort C4570 | ApeosPort | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort C5570 | ApeosPort | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort C6570 | ApeosPort | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort C7070 | ApeosPort | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII 4021 | ApeosPort-VII | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII 5021 | ApeosPort-VII | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII C3321 | ApeosPort-VII | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII C4421 | ApeosPort-VII | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII C5588 | ApeosPort-VII | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VII C2273(APAC model):
Controller ROM: 1.1.13
SJFI: 4.21.0
SSMI: 2.101.0
Plugin: 3.0.5
XCP: 2.1.0
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII C6688 | ApeosPort-VII | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VII C2273(APAC model):
Controller ROM: 1.1.13
SJFI: 4.21.0
SSMI: 2.101.0
Plugin: 3.0.5
XCP: 2.1.0
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII C7788 | ApeosPort-VII | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VII C2273(APAC model):
Controller ROM: 1.1.13
SJFI: 4.21.0
SSMI: 2.101.0
Plugin: 3.0.5
XCP: 2.1.0
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | C9070 | PrimeLink | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
PrimeLink C9065:
Controller ROM: 1.0.11
SJFI: 4.20.0
SSMI: 2.100.0
Plugin: 2.4.2
General
SafeQ5
XCP Terminal requires FW version supporting XCP 1.2+.
SafeQ6
XCP Terminal (Generation 2) requires FW version supporting XCP1.4+.
Common
USB Card reader can be used in combination with XCP plugin terminal.
EPA Card reader can be used in combination with native terminal with Authentication Agent.
Installation and uninstallation
SafeQ5
XCP Terminal not tested yet
SafeQ6
XCP Terminal requires combination of SafeQ6 MU29 or newer.
XCP Terminal uninstallation with FW1.1.101 requires the manual steps bellow. This will be solved with the next release firmware. For details, please contact Fuji Xerox.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Interface
Common
Billing code application footer "My billing codes for Copy, Scan and FAX" too long and cannot be displayed in full. Fix is planned in later MU.
Print
SafeQ6
Attempt to auto fix incompatible Duplex job to Simplex job does not release the print job. (“ showIncompatibleJobs=true” and the system tag “duplex unchecked”). Fix is planned in MU31
Scanning
SafeQ5
Workflow scan does not support XDW format.
SafeQ6
Workflow scan does not support XPS and XDW format.
Common
Scan to 1/2 color using Scan workflow generates BW scan because 1/2 colors scan is not supported by the device.
Scan to JPEG and TIFF fails with the error 018-571. Under investigation by Fuji Xerox.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System does not work. Debts is registered. This will be solved with the next release FW. For details, please contact Fuji Xerox.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
||
Fuji Xerox | C9065 | PrimeLink | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
PrimeLink C9065:
Controller ROM: 1.0.11
SJFI: 4.20.0
SSMI: 2.100.0
Plugin: 2.4.2
General
SafeQ5
XCP Terminal requires FW version supporting XCP 1.2+.
SafeQ6
XCP Terminal (Generation 2) requires FW version supporting XCP1.4+.
Common
USB Card reader can be used in combination with XCP plugin terminal.
EPA Card reader can be used in combination with native terminal with Authentication Agent.
Installation and uninstallation
SafeQ5
XCP Terminal not tested yet
SafeQ6
XCP Terminal requires combination of SafeQ6 MU29 or newer.
XCP Terminal uninstallation with FW1.1.101 requires the manual steps bellow. This will be solved with the next release firmware. For details, please contact Fuji Xerox.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Interface
Common
Billing code application footer "My billing codes for Copy, Scan and FAX" too long and cannot be displayed in full. Fix is planned in later MU.
Print
SafeQ6
Attempt to auto fix incompatible Duplex job to Simplex job does not release the print job. (“ showIncompatibleJobs=true” and the system tag “duplex unchecked”). Fix is planned in MU31
Scanning
SafeQ5
Workflow scan does not support XDW format.
SafeQ6
Workflow scan does not support XPS and XDW format.
Common
Scan to 1/2 color using Scan workflow generates BW scan because 1/2 colors scan is not supported by the device.
Scan to JPEG and TIFF fails with the error 018-571. Under investigation by Fuji Xerox.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System does not work. Debts is registered. This will be solved with the next release FW. For details, please contact Fuji Xerox.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
||
Fuji Xerox | ApeosPort-VII C5573 | ApeosPort-VII | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VII C2273(APAC model):
Controller ROM: 1.1.13
SJFI: 4.21.0
SSMI: 2.101.0
Plugin: 3.0.5
XCP: 2.1.0
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII C7773 | ApeosPort-VII | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VII C2273(APAC model):
Controller ROM: 1.1.13
SJFI: 4.21.0
SSMI: 2.101.0
Plugin: 3.0.5
XCP: 2.1.0
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII C6673 | ApeosPort-VII | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VII C2273(APAC model):
Controller ROM: 1.1.13
SJFI: 4.21.0
SSMI: 2.101.0
Plugin: 3.0.5
XCP: 2.1.0
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII C4473 | ApeosPort-VII | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VII C2273(APAC model):
Controller ROM: 1.1.13
SJFI: 4.21.0
SSMI: 2.101.0
Plugin: 3.0.5
XCP: 2.1.0
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII C3373 | ApeosPort-VII | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VII C2273(APAC model):
Controller ROM: 1.1.13
SJFI: 4.21.0
SSMI: 2.101.0
Plugin: 3.0.5
XCP: 2.1.0
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII C3372 | ApeosPort-VII | Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VII C2273(APAC model):
Controller ROM: 1.1.13
SJFI: 4.21.0
SSMI: 2.101.0
Plugin: 3.0.5
XCP: 2.1.0
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VII C2273 | ApeosPort-VII | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Information about the tested device
ApeosPort-VII C2273(APAC model):
Controller ROM: 1.1.13
SJFI: 4.21.0
SSMI: 2.101.0
Plugin: 3.0.5
XCP: 2.1.0
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
SafeQ Cloud
Only ApeosPort-VII Gen2 installed with AIP7 FW with XCP 2.0.0+ and EWB v5.x is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | DocuPrint P365d | DocuPrint | No |
No |
No |
No |
No |
No |
No |
LD device from YSoft SafeQ 6 MU22. | No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 MU22.
|
|
Fuji Xerox | Color 560 | Production Printer | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Untested |
No |
No |
Yes |
No |
Terminal Embedded was tested with optional print controller (internal Fiery) Fiery do not block Server - Printer printing Printing via fiery is feasible however fiery doesnt parsing username to Printer;therefore SafeQ only able to capture job name (username: unknown) FW: Controller ROM:1.145.9 IOT ROM:64.24.0 Finisher C ROM:18.32.0 SSMI:1.15.101 SJFI:3.0.17 IIT:6.18.0
|
||
Fuji Xerox | 3035 | DocuWide | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | 202 | DocuPrint | No |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | 3105 | DocuPrint | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | CP305d | DocuPrint | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | Docu Centre 900 | Docu Centre | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | Docu Centre 1100 | Docu Centre | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | Docu Centre 236 | Docu Centre | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | Docu Centre 286 | Docu Centre | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | Docu Centre 336 | Docu Centre | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | Docu Centre C250 | Docu Centre | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | Docu Centre C360 | Docu Centre | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | Docu Centre C450 | Docu Centre | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | Docu Centre 1085 | Docu Centre | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | Docu Centre 1055 | Docu Centre | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox | Versant™ 80 Press | Production | Yes |
Yes |
Yes |
Yes |
No |
FUJI-XEROX-MFP-COL-PRODUCTION-BETA | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW Versant 180(Tested for Non-XCP with EPA reader only):
Controller ROM: 1.3.13
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: No
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on Versant models.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
A device with an ptional print controllers - GX, GXI, EX, EX-i, FreeFlow are not suported.
|
Fuji Xerox | Color C70 | Production | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Terminal Embedded was tested without using an optional print controller ( Linkage of Fiery with MFP removed )
|
||
Fuji Xerox | Color C60 | Production | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Terminal Embedded was tested without using an optional print controller ( Linkage of Fiery with MFP removed )
|
||
Fuji Xerox | ApeosPort-V 3065 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW 3060:
Controller ROM: 1.1.8
SJFI: 3.10.0
SSMI: 1.25.4
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
||
Fuji Xerox | ApeosPort-V 3060 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW 3060:
Controller ROM: 1.1.8
SJFI: 3.10.0
SSMI: 1.25.4
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
||
Fuji Xerox | ApeosPort-V 2060 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW 3060:
Controller ROM: 1.1.8
SJFI: 3.10.0
SSMI: 1.25.4
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
||
Fuji Xerox | ApeosPort-V C7785 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C5580
Controller ROM: 1.3.7
SJFI: Version 3.5.0
SSMI: Version 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-V C6685 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C5580
Controller ROM: 1.3.7
SJFI: Version 3.5.0
SSMI: Version 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-V C5585 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C5580
Controller ROM: 1.3.7
SJFI: Version 3.5.0
SSMI: Version 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | ApeosPort-VI C2271 | ApeosPort-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VI C2271(APAC model):
Controller ROM: 1.1.11
SJFI: 3.10.0
SSMI: 1.26.1
Plugin: 1.1.5
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort Print C3570 | ApeosPort Print | No |
Yes |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-A4-DUP | Yes |
Yes |
There is a 3 seconds timeout after print. ApeosPort Print C4570 does FALSEt have the Large paper size counter and A3 is accounted as A4. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort Print C4570
System: 20.6.17
Controller ROM: 1.5.3
IOT ROM: 72.6.0
Panel ROM: 240.109.18
Boot ROM: 1.0.80
SJFI: 5.0.0
SSMI: 2.104.0
Contents: 4.9.5
Plugin: 4.9.3
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
SafeQ Cloud
Only ApeosPort-VII Generation 2 installed with AIP7 FW with XCP v2.2.0+ and EWB v5 is supported.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | DocuPrint CM318 z | DocuPrint | Yes |
No |
Yes |
Yes |
No |
FUJI-XEROX-MFP-COL-A4-CM315 | No |
No |
Scan counter starts from 1. Scan to USB is FALSEt accounted. (Only Scan transfered via network/mail is accounted). Duplex copy is accounted as simplex. Duplex print is detected from print job parser. | No |
Untested |
Yes |
No |
No |
No |
|
Fuji Xerox | DocuPrint CP318 dw | DocuPrint | No |
No |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-DP-CP405D | No |
No |
Duplex print is accounted according to parser from job information. | No |
Untested |
Yes |
No |
No |
No |
|
Fuji Xerox | P378 dw | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-PRN-BW-DPP375 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | P378 d | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-PRN-BW-DPP375 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | P375 dw | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-PRN-BW-DPP375 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | P375 d | DocuPrint | No |
No |
No |
Yes |
No |
FUJI-XEROX-PRN-BW-DPP375 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Fuji Xerox | M378 df | DocuPrint | Yes |
No |
No |
Yes |
No |
FUJI-XEROX-MFP-BW-DPM375 | No |
No |
Status detection based on display messages is supported for English, Chinese and Indonesian languages. Status detection of the error "FALSE Paper Fed" is FALSEt supported for Chinese and Indonesian languages. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | M378 d | DocuPrint | Yes |
No |
No |
Yes |
No |
FUJI-XEROX-MFP-BW-DPM375 | No |
No |
Status detection based on display messages is supported for English, Chinese and Indonesian languages. Status detection of the error "FALSE Paper Fed" is FALSEt supported for Chinese and Indonesian languages. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | M375 z | DocuPrint | Yes |
No |
No |
Yes |
No |
FUJI-XEROX-MFP-BW-DPM375 | No |
No |
Status detection based on display messages is supported for English, Chinese and Indonesian languages. Status detection of the error "FALSE Paper Fed" is FALSEt supported for Chinese and Indonesian languages. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | M375 df | DocuPrint | Yes |
No |
No |
Yes |
No |
FUJI-XEROX-MFP-BW-DPM375 | No |
No |
Status detection based on display messages is supported for English, Chinese and Indonesian languages. Status detection of the error "FALSE Paper Fed" is FALSEt supported for Chinese and Indonesian languages. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-V 3070 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan counter starts from 1. Each A3 page is accounted as A4 page. When Offline copy accounting is used, each A3 page is accounted as two A4 pages. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW version 5070:
Controller ROM: 1.0.12
SJFI: Version 3.7.0
SSMI: Version 1.24.0
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is supported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | ApeosPort-V C3374 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
The device with following FW was tested:
Cpntroller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox | DocuPrint CM315 z | DocuPrint | Yes |
No |
Yes |
Yes |
No |
FUJI-XEROX-MFP-COL-A4-CM315 | No |
No |
Scan counter starts from 1. Scan to USB is FALSEt accounted. (Only Scan transfered via network/mail is accounted). Duplex copy is accounted as simplex. Duplex print is detected from print job parser. | No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 MU22.
|
Fuji Xerox | DocuPrint CP315 dw | DocuPrint | No |
No |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-DP-CP405D | No |
No |
uplex print is accounted according to parser from job information. | No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 MU22.
|
Fuji Xerox | B9136 | Light Publisher | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
B9136
Controller ROM: 1.0.3
SJFI: 3.10.0
SSMI: 1.27.0
Plugin: 1.3.0
Test was done without GX Print Server.
When GX Print Server is connected, print job management by SafeQ is not available (secure print via SafeQ), but only accounting result are tracked by SafeQ. Username would be parsed from print driver so user name matching Dispatcher Paragon user name shall be set to printer driver when submitting a print job to GX Print Server.
General
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | B9125 | Light Publisher | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
B9136
Controller ROM: 1.0.3
SJFI: 3.10.0
SSMI: 1.27.0
Plugin: 1.3.0
Test was done without GX Print Server.
When GX Print Server is connected, print job management by SafeQ is not available (secure print via SafeQ), but only accounting result are tracked by SafeQ. Username would be parsed from print driver so user name matching Dispatcher Paragon user name shall be set to printer driver when submitting a print job to GX Print Server.
General
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | B9110 | Light Publisher | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
B9136
Controller ROM: 1.0.3
SJFI: 3.10.0
SSMI: 1.27.0
Plugin: 1.3.0
Test was done without GX Print Server.
When GX Print Server is connected, print job management by SafeQ is not available (secure print via SafeQ), but only accounting result are tracked by SafeQ. Username would be parsed from print driver so user name matching Dispatcher Paragon user name shall be set to printer driver when submitting a print job to GX Print Server.
General
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox | B9100 | Light Publisher | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW B9136:
Controller ROM: 1.0.3
SJFI: 3.10.0
SSMI: 1.27.0
Plugin: 1.3.0
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
Test was done without GX Print Server.
When GX Print Server is connected, print job management by Dispatcher Paragon is not available (secure print via SafeQ), but only accounting result are tracked by SafeQ. Username would be parsed from print driver so user name matching Dispatcher Paragon user name shall be set to printer driver when submitting a print job to GX Print Server.
|
||
Fuji Xerox | DocuPrint CP555 d | DocuPrint | No |
No |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-CP555 | No |
No |
Recommended driver: FUJI-XEROX-PRN-COL-CP555 | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | DocuPrint CP505 d | DocuPrint | No |
No |
Yes |
Yes |
No |
FUJI-XEROX-PRN-COL-CP555 | No |
No |
Recommended driver: FUJI-XEROX-PRN-COL-CP555 | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox | ApeosPort-VI C3370 | ApeosPort-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device
ApeosPort-VI C2271(APAC model):
Controller ROM: 1.1.11
SJFI: 3.10.0
SSMI: 1.26.1
Plugin: 1.1.5
General
USB Card reader can be used in combination with XCP plugin terminal.
EPA Card reader can be used in combination with native terminal with Authentication Agent.
EPA interface has not been supported from ApeosPort-VI(2016) for 3rd party partners by Fuji Xerox. The device has EPA connector on the back panel, however the EPA interface operation is not guarantee by Fuji Xerox. So correct functioning of the EPA card reader is not guaranteed.
Copying
For XCP terminal to restrict Full Color copy by SafeQ user Access Right, the setting bellow shall be applied to the device.
Log in to the device as Administrator -> tools -> Authentication/Security Settings -> Authentication -> Access Control -> Feature access -> Color Copying (change it to Locked) -> Save -> Navigate out of all settings and reboot the device.
Scanning
SafeQ5
Workflow scan does not support XDW format.
SafeQ6
Workflow scan does not support XPS and XDW format.
Common
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black).
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-VI C7771 | ApeosPort-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VI C2271(APAC model):
Controller ROM: 1.1.11
SJFI: 3.10.0
SSMI: 1.26.1
Plugin: 1.1.5
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-VI C6671 | ApeosPort-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VI C2271(APAC model):
Controller ROM: 1.1.11
SJFI: 3.10.0
SSMI: 1.26.1
Plugin: 1.1.5
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-VI C5571 | ApeosPort-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VI C2271(APAC model):
Controller ROM: 1.1.11
SJFI: 3.10.0
SSMI: 1.26.1
Plugin: 1.1.5
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-VI C4471 | ApeosPort-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VI C2271(APAC model):
Controller ROM: 1.1.11
SJFI: 3.10.0
SSMI: 1.26.1
Plugin: 1.1.5
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox | ApeosPort-VI C3371 | ApeosPort-VI | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-APO | No |
No |
There is a 3 seconds timeout after print. Scan counter starts from 1. Driver can be set for offline copy accounting. Scan to storage is FALSEt accounted. (Only Scan transfered via network is accounted). | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VI C2271(APAC model):
Controller ROM: 1.1.11
SJFI: 3.10.0
SSMI: 1.26.1
Plugin: 1.1.5
General
XCP Terminal requires FW1.1.101 or newer.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox(JAPAN) | Versant™ 180 Press | Production | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Untested |
No |
No |
Yes |
Yes |
A device with an ptional print controllers - GX, GXI, EX, EX-i, FreeFlow are not suported.
XCP Terminal with USB card reader is not supported. NON-XCP terminal with EPA reader should be used.
|
||
Fuji Xerox(JAPAN) | ApeosPort-VI C2271 | ApeosPort-VI | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
ApeosPort-VI C3371
Controller ROM: 1.0.19
SJFI: 3.9.0
SSMI: 1.26.0
Plugin: 1.1.2
Plugin platform: 2.0.0
General
USB Card reader can be used in combination with XCP plugin terminal.
EPA Card reader can be used in combination with native terminal with Authentication Agent.
EPA interface has not been supported from ApeosPort-VI(2016) for 3rd party partners by Fuji Xerox. The device has EPA connector on the back panel, however the EPA interface operation is not guarantee by Fuji Xerox. So correct functioning of the EPA card reader is not guaranteed.
Copying
For XCP terminal to restrict Full Color copy by SafeQ user Access Right, the setting bellow shall be applied to the device.
Log in to the device as Administrator -> tools -> Authentication/Security Settings -> Authentication -> Access Control -> Feature access -> Color Copying (change it to Locked) -> Save -> Navigate out of all settings and reboot the device.
Scanning
SafeQ5
Workflow scan does not support XDW format.
SafeQ6
Workflow scan does not support XPS and XDW format.
Common
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black).
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox(JAPAN) | C7500 | DocuCentre-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP Limitations: Use this driver if the Controller ROM version is 1.42.xx or newer. / There is a 1 second timeout after print. / There is a 1 second timeout after copy. / Each A3 page is accounted as A4 page. / Duplex copy is accounted as simplex. / Duplex print is accounted according to parser from job information. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C6500 | DocuCentre-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP Limitations: Use this driver if the Controller ROM version is 1.42.xx or newer. / There is a 1 second timeout after print. / There is a 1 second timeout after copy. / Each A3 page is accounted as A4 page. / Duplex copy is accounted as simplex. / Duplex print is accounted according to parser from job information. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C5400 | DocuCentre-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP Limitations: Use this driver if the Controller ROM version is 1.42.xx or newer. / There is a 1 second timeout after print. / There is a 1 second timeout after copy. / Each A3 page is accounted as A4 page. / Duplex copy is accounted as simplex. / Duplex print is accounted according to parser from job information. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C4300 | DocuCentre-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP Limitations: Use this driver if the Controller ROM version is 1.42.xx or newer. / There is a 1 second timeout after print. / There is a 1 second timeout after copy. / Each A3 page is accounted as A4 page. / Duplex copy is accounted as simplex. / Duplex print is accounted according to parser from job information. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C3300 | DocuCentre-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP Limitations: Use this driver if the Controller ROM version is 1.42.xx or newer. / There is a 1 second timeout after print. / There is a 1 second timeout after copy. / Each A3 page is accounted as A4 page. / Duplex copy is accounted as simplex. / Duplex print is accounted according to parser from job information. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C2200 | DocuCentre-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP Limitations: Use this driver if the Controller ROM version is 1.42.xx or newer. / There is a 1 second timeout after print. / There is a 1 second timeout after copy. / Each A3 page is accounted as A4 page. / Duplex copy is accounted as simplex. / Duplex print is accounted according to parser from job information. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-II C7500 | ApeosPort-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP Limitations: Use this driver if the Controller ROM version is 1.42.xx or newer. / There is a 1 second timeout after print. / There is a 1 second timeout after copy. / Each A3 page is accounted as A4 page. / Duplex copy is accounted as simplex. / Duplex print is accounted according to parser from job information. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-II C6500 | ApeosPort-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP Limitations: Use this driver if the Controller ROM version is 1.42.xx or newer. / There is a 1 second timeout after print. / There is a 1 second timeout after copy. / Each A3 page is accounted as A4 page. / Duplex copy is accounted as simplex. / Duplex print is accounted according to parser from job information. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-II C5400 | ApeosPort-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP Limitations: Use this driver if the Controller ROM version is 1.42.xx or newer. / There is a 1 second timeout after print. / There is a 1 second timeout after copy. / Each A3 page is accounted as A4 page. / Duplex copy is accounted as simplex. / Duplex print is accounted according to parser from job information. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-II C4300 | ApeosPort-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP Limitations: Use this driver if the Controller ROM version is 1.42.xx or newer. / There is a 1 second timeout after print. / There is a 1 second timeout after copy. / Each A3 page is accounted as A4 page. / Duplex copy is accounted as simplex. / Duplex print is accounted according to parser from job information. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-II 3300 | ApeosPort-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP Limitations: Use this driver if the Controller ROM version is 1.42.xx or newer. / There is a 1 second timeout after print. / There is a 1 second timeout after copy. / Each A3 page is accounted as A4 page. / Duplex copy is accounted as simplex. / Duplex print is accounted according to parser from job information. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-II C2200 | ApeosPort-II | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-COL-DUP-AP-II-C4300-JP Limitations: Use this driver if the Controller ROM version is 1.42.xx or newer. / There is a 1 second timeout after print. / There is a 1 second timeout after copy. / Each A3 page is accounted as A4 page. / Duplex copy is accounted as simplex. / Duplex print is accounted according to parser from job information. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C7600 | DocuCenter-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C6500 | DocuCenter-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C5500 | DocuCenter-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C4405 | DocuCenter-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C4400 | DocuCenter-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C3305 | DocuCenter-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C3300 | DocuCenter-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C2205 | DocuCenter-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C2200 | DocuCenter-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-III C7600 | ApeosPort-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-III C6500 | ApeosPort-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-III C5500 | ApeosPort-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-III C4405 | ApeosPort-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-III C3305 | ApeosPort-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-III C2205 | ApeosPort-III | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-III 7000 | ApeosPort-III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-APIII-4000-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-APIII-4000-JP Limitations: Each A3 page is accounted as A4 page. / Scan to USB is FALSEt accounted. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-III 6000 | ApeosPort-III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-APIII-4000-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-APIII-4000-JP Limitations: Each A3 page is accounted as A4 page. / Scan to USB is FALSEt accounted. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-III 5000 | ApeosPort-III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-APIII-4000-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-APIII-4000-JP Limitations: Each A3 page is accounted as A4 page. / Scan to USB is FALSEt accounted. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-III 4000 | ApeosPort-III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-APIII-4000-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-APIII-4000-JP Limitations: Each A3 page is accounted as A4 page. / Scan to USB is FALSEt accounted. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | ApeosPort-III 3010 | ApeosPort-III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-APIII-4000-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-APIII-4000-JP Limitations: Each A3 page is accounted as A4 page. / Scan to USB is FALSEt accounted. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C7780 | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C6680 | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C5580 | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C5575 | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C5570 | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C4475 | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C4470 | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C3375 | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C3370 | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C2275 | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C2270 | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C2263N | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C2263 | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | C2260 | DocuCenter-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | 7080 | DocuCenter-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | 6080 | DocuCenter-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | 5080 | DocuCenter-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | 4070 | DocuCenter-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | 3070 | DocuCenter-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | 3060 | DocuCenter-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | 2060 | DocuCenter-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | Docu Centre V C7780 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | Docu Centre V C7775 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | Docu Centre V C6680 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | Docu Centre V C6675 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | Docu Centre V C5580 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | Docu Centre V C4475 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | Docu Centre V C3375 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | Docu Centre V C2275 | Docu Centre V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | Docu Centre V 7080 | Docu Centre V | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | Docu Centre V 6080 | Docu Centre V | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | Docu Centre V 5070 | Docu Centre V | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | Docu Centre V 4070 | Docu Centre V | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | Docu Centre V 3070 | Docu Centre V | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | D110 Light Publisher | Production | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Untested |
No |
No |
Yes |
No |
Tested FW: D125=1.104.12
|
||
Fuji Xerox(JAPAN) | D125 | Production | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Untested |
No |
No |
Yes |
No |
Tested FW: D125=1.104.12
|
||
Fuji Xerox(JAPAN) | ApeosPort-IV C5570 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW 2270 = 1.104.28
Tested FW = 1.104.28
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
ART-EX driver is not supported.
For preview, Color print control, Rule-base print, use PCL/Postscript driver.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV C4470 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW = 1.104.28
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
ART-EX driver is not supported.
For preview, Color print control, Rule-base print, use PCL/Postscript driver.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV C3370 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW 2270 = 1.104.28
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
ART-EX driver is not supported.
For preview, Color print control, Rule-base print, use PCL/Postscript driver.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV C2270 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW = 1.104.28
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
ART-EX driver is not supported.
For preview, Color print control, Rule-base print, use PCL/Postscript driver.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV C7780 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Untested |
No |
No |
Yes |
Yes |
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
ART-EX driver is not supported.
For preview, Color print control, Rule-base print, use PCL/Postscript driver.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV C6680 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Untested |
No |
No |
Yes |
Yes |
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
ART-EX driver is not supported.
For preview, Color print control, Rule-base print, use PCL/Postscript driver.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV C5580 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Untested |
No |
No |
Yes |
Yes |
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
ART-EX driver is not supported.
For preview, Color print control, Rule-base print, use PCL/Postscript driver.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV 4070 | ApeosPort-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW: 5070=1.120.3
Tesdted FW: 4070 = 1.120.14
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
ART-EX driver is not supported for
preview, Color print control, Rule-base print, use PCL/Postscript driver.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV 3070 | ApeosPort-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW: 5070=1.120.3
Tesdted FW: 4070 = 1.120.14
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal Generation 1/2 and USB card reader are not suported on ApeosPort-IV Generation 1 models with XCP version 1.1.x and older.
ART-EX driver is not supported for
preview, Color print control, Rule-base print, use PCL/Postscript driver.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV 7080 | ApeosPort-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW: 6080=1.101.9, 7080=1.101.9
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
ART-EX driver is not supported for
preview, Color print control, Rule-base print, use PCL/Postscript driver.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV 6080 | ApeosPort-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW: 6080=1.101.9, 7080=1.101.9
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
ART-EX driver is not supported for
preview, Color print control, Rule-base print, use PCL/Postscript driver.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV 5080 | ApeosPort-IV | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW: 6080=1.101.9, 7080=1.101.9
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
ART-EX driver is not supported for
preview, Color print control, Rule-base print, use PCL/Postscript driver.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV C5575 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C2275(APAC MODEL)
Controller ROM: 1.131.5
SJFI: 3.3.0
SSMI: 1.20.1
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal and USB interface Card reader are not supported on ApeosPort-IV generation 1 models with XCP version older than 1.2.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV C4475 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Untested |
No |
No |
Yes |
Yes |
Tested FW C2275(APAC MODEL)
Controller ROM: 1.131.5
SJFI: 3.3.0
SSMI: 1.20.1
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal and USB interface Card reader are not supported on ApeosPort-IV generation 1 models with XCP version older than 1.2.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-IV C2275 | ApeosPort-IV | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C2275(APAC model)(Tested for Non-XCP with EPA reader only):
Controller ROM: 1.131.5
SJFI: 3.3.0
SSMI: 1.20.1
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: No
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
XCP Terminal and USB interface Card reader are not supported on ApeosPort-IV generation 1 models with XCP version older than 1.2.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is suported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
YSF Universal Print Driver(PCL) is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-V C7780 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
For 5575 and 3375, there are 2 types of controller versions: 1.0, 1.40
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
YSF Universal Print Driver is suppoeted if optional PCL engine is enabled.
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox(JAPAN) | ApeosPort-V C6680 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
YSF Universal Print Driver is suppoeted if optional PCL engine is enabled.
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox(JAPAN) | ApeosPort-V C7775 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C7775(APAC model):
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
For 5575 and 3375, there are 2 types of controller versions: 1.0, 1.40
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
YSF Universal Print Driver is suppoeted if optional PCL engine is enabled.
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox(JAPAN) | ApeosPort-V C6675 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C7775(AAPC model):
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
YSF Universal Print Driver is suppoeted if optional PCL engine is enabled.
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox(JAPAN) | ApeosPort-V C5580 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
For 5575 and 3375, there are 2 types of controller versions: 1.0, 1.40
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
YSF Universal Print Driver is suppoeted if optional PCL engine is enabled.
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox(JAPAN) | ApeosPort-V C5575 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C7775(APAC model):
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
For 5575 and 3375, there are 2 types of controller versions: 1.0, 1.40
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
YSF Universal Print Driver is suppoeted if optional PCL engine is enabled.
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox(JAPAN) | ApeosPort-V C4475 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C7775(APAC model):
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
For 5575 and 3375, there are 2 types of controller versions: 1.0, 1.40
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
YSF Universal Print Driver is suppoeted if optional PCL engine is enabled.
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox(JAPAN) | ApeosPort-V C3375 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C7775(APAC model):
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
For 5575 and 3375, there are 2 types of controller versions: 1.0, 1.40
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
YSF Universal Print Driver is suppoeted if optional PCL engine is enabled.
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox(JAPAN) | ApeosPort-V C2275 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW C7775(APAC model):
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
For 5575 and 3375, there are 2 types of controller versions: 1.0, 1.40
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
YSF Universal Print Driver is suppoeted if optional PCL engine is enabled.
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox(JAPAN) | ApeosPort-V C7780 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C5580
Controller ROM: 1.3.7
SJFI: Version 3.5.0
SSMI: Version 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox(JAPAN) | ApeosPort-V C6680 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C5580
Controller ROM: 1.3.7
SJFI: Version 3.5.0
SSMI: Version 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox(JAPAN) | ApeosPort-V C7775 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox(JAPAN) | ApeosPort-V C6675 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox(JAPAN) | ApeosPort-V C5580 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C5580
Controller ROM: 1.3.7
SJFI: Version 3.5.0
SSMI: Version 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox(JAPAN) | ApeosPort-V C5575 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox(JAPAN) | ApeosPort-V C4475 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox(JAPAN) | ApeosPort-V C3375 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox(JAPAN) | ApeosPort-V C2275 T2 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCV-CXXX5-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCV-CXXX5-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C7775:
Controller ROM: 1.3.26
SJFI: 3.5.0
SSMI: 1.21.0
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
Fuji Xerox(JAPAN) | ApeosPort-V 4020 | ApeosPort-V | Yes |
No |
No |
Yes |
Yes |
FUJI-XEROX-MFP-APBW | No |
No |
Recommended driver: FUJI-XEROX-MFP-APBW Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
DocuPrint M465 AP requirs optional External Access Kit to run Terminal Embedded
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is supported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox(JAPAN) | ApeosPort-V C3320 | ApeosPort-V | Yes |
No |
Yes |
Yes |
Yes |
FUJI-XEROX-MFP-APDCIV-C4430-APO | No |
No |
Recommended driver: FUJI-XEROX-MFP-APDCIV-C4430-APO Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Color print control, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW: CM415AP
Controller ROM: 1.2.7
SJFI: 3.7.1
SJFI: 3.7.1
Tested FW: C3320
Controller ROM: 1.2.5
DocuPrint CM415 AP requirs optional External Access Kit to run Terminal Embedded
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is supported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
YSF Universal Print Driver is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-V 7080 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW 6080:
Controller ROM: 1.0.16
SJFI: 3.7.2
SSMI: 1.24.2
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is supported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
YSF Universal Print Driver is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-V 6080 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
For 4070, there are 2 types of controller versions: 1.0, 1.40
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
YSF Universal Print Driver is suppoeted if optional PCL engine is enabled.
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox(JAPAN) | ApeosPort-V 5080 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
For 4070, there are 2 types of controller versions: 1.0, 1.40
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
YSF Universal Print Driver is suppoeted if optional PCL engine is enabled.
USB card reader is suported with XCP terminal.
2nd Gen Browser terminal is not tested.
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
|
Fuji Xerox(JAPAN) | ApeosPort-V 4070 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW version 5070:
Controller ROM: 1.0.12
SJFI: Version 3.7.0
SSMI: Version 1.24.0
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is supported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
YSF Universal Print Driver is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | ApeosPort-V 3070 | ApeosPort-V | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-DCIV-XX80-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-DCIV-XX80-JP Limitations: There is a 3 seconds timeout after print. Scan to storage is FALSEt accounted.(Only Scan transfered via network is accounted) Scan counters starts from 1. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
Tested FW version 5070:
Controller ROM: 1.0.12
SJFI: Version 3.7.0
SSMI: Version 1.24.0
Tested Terminal
Non-XCP Generation 1: YES
NON-XCP Generation 2: No
XCP Generation 1: YES
XCP Generation 2: No
EPA interface Card reader is supported with EBW terminal using Authentication Agent.
For XCP Terminal Generation 1 and USB card reader, FW version supporting XCP 1.2+ required.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
USB card reader is supported in combination with XCP terminal.
RBE - Watermark does not work
Scan in Black color with Workflow Scan generates Graycolor scan
Scan to JPEG in 1 color or 2 colors with Workflow Scan generates TIFF in Black (Device does not support 1 color or 2 colors scan and JPEG in Black)
When Payment system is integrated and the parameter "fujiXeroxEnableDefaultQuotaTogglingStrategy" is set to "disabled", Print All jobs after login function is not supported.
YSF Universal Print Driver is supported if optional PCL engine is enabled.
|
Fuji Xerox(JAPAN) | 3100 | DocuPrint | No |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | 3000 | DocuPrint | No |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | 7000 | DocuCentre-II | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | 6000 | DocuCentre-II | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | 5000 | DocuCentre-II | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | 4000 | DocuCentre-II | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | 3000 | DocuCentre-II | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | ApeosPort-II 7000 | ApeosPort-II | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | ApeosPort-II 6000 | ApeosPort-II | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | ApeosPort-II 5000 | ApeosPort-II | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | ApeosPort-II 4000 | ApeosPort-II | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | ApeosPort-II 3000 | ApeosPort-II | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Fuji Xerox(JAPAN) | 7000 | DocuCenter-III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-APIII-4000-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-APIII-4000-JP Limitations: Each A3 page is accounted as A4 page. / Scan to USB is FALSEt accounted. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | 6000 | DocuCenter-III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-APIII-4000-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-APIII-4000-JP Limitations: Each A3 page is accounted as A4 page. / Scan to USB is FALSEt accounted. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | 5000 | DocuCenter-III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-APIII-4000-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-APIII-4000-JP Limitations: Each A3 page is accounted as A4 page. / Scan to USB is FALSEt accounted. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | 4000 | DocuCenter-III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-APIII-4000-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-APIII-4000-JP Limitations: Each A3 page is accounted as A4 page. / Scan to USB is FALSEt accounted. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | 3010 | DocuCenter-III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-APIII-4000-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-APIII-4000-JP Limitations: Each A3 page is accounted as A4 page. / Scan to USB is FALSEt accounted. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | 3000 | DocuCenter-III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-APIII-4000-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-APIII-4000-JP Limitations: Each A3 page is accounted as A4 page. / Scan to USB is FALSEt accounted. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | 2000 | DocuCenter-III | Yes |
Yes |
No |
Yes |
Yes |
FUJI-XEROX-MFP-BW-A3-APIII-4000-JP | No |
No |
Recommended driver: FUJI-XEROX-MFP-BW-A3-APIII-4000-JP Limitations: Each A3 page is accounted as A4 page. / Scan to USB is FALSEt accounted. For Preview, Rule-base print, use PCL/Postscript driver. Default ART-EX driver is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Fuji Xerox(JAPAN) | Versant™ 80 Press | Production | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Untested |
No |
No |
Yes |
Yes |
A device with an ptional print controllers - GX, GXI, EX, EX-i, FreeFlow are not suported.
XCP Terminal with USB card reader is not supported. NON-XCP terminal with EPA reader should be used.
|
||
Fuji Xerox(JAPAN) | ApeosPort-V C7776 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C2276:
Controller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox(JAPAN) | ApeosPort-V C6676 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C2276:
Controller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox(JAPAN) | ApeosPort-V C5576 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C2276:
Controller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox(JAPAN) | ApeosPort-V C4476 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C2276:
Controller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox(JAPAN) | ApeosPort-V C3376 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C2276:
Controller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox(JAPAN) | ApeosPort-V C2276 | ApeosPort-V | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device
C2276:
Controller ROM: 1.2.2
SJFI: 3.10.0
SSMI: 1.25.4
Contents: 2.0.12
Plugin: 1.0.6
General
XCP Terminal Generation 1 and USB card reader requires FW version supporting XCP 1.2+.
XCP Terminal Generation 2 requires FW version supporting XCP1.4+.
AIP7(FUJIFILM BI(ACTIVE)) is not supported.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ 75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX XCP(Maintained) when installing Terminal Embedded.
Build76 and newer - Non-XCP Native Authentication Agent is still supported. Choose FUJI XEROX(Maintained) for installation.
Installation and uninstallation
XCP Terminal requires Signature Verification disabled.
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
Fuji Xerox(JAPAN) | DocuPrint CP500 d | DocuPrint | No |
No |
Yes |
No |
No |
FUJI-XEROX-PRN-COL-CP555 | No |
No |
Recommended driver: FUJI-XEROX-PRN-COL-CP555 | No |
Untested |
No |
No |
No |
No |
|
FUJIFILM BI | ApeosPort Print C3320SD | ApeosPort Print | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
A4 Color Printer with no support for embedded terminal. |
||
FUJIFILM BI | ApeosPort Print C3830SD | ApeosPort Print | No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|
||
FUJIFILM BI | ApeosPort C3320SD | ApeosPort | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
|
||
FUJIFILM BI | ApeosPort C3830SD | ApeosPort | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|
||
FUJIFILM BI | ApeosPrint C3060 S | ApeosPrint | No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
No |
|||
FUJIFILM BI | ApeosPrint C3560 S | ApeosPrint | No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device
ApeosPrint C3560S, ApeosPrint C3060 S
This model supports only Apeos IntegrationPlus 7(AIP7).
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI (Maintained) : Not supported.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow.
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Printing
The models supports only ART EX ( with optional PS3 - ApeosPrint C3560S only)
Payment System
After authentication, it can take 20 ~ 30 before a user lands on the home.(To be investigated)
|
||
FUJIFILM BI | Apeos 5330 | Apeos | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI (Maintained) : Not supported.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow.
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Printing
Japan model does not support PCL
Payment System
Login speed improvement with Payment System is planned for build 77
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C3530 | Apeos | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI (Maintained) : Not supported.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow.
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Printing
Japan model does not support PCL
Payment System
Login speed improvement with Payment System is planned for build 77
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C4030 | Apeos | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI (Maintained) : Not supported.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow.
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Printing
Japan model does not support PCL
Payment System
Login speed improvement with Payment System is planned for build 77
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | ApeosPrint 4830 | ApeosPrint | No |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device
Apeos C4430
This model supports only Apeos IntegrationPlus 7(AIP7).
System: 22.10.21
Controller ROM: 1.20.5
IOT ROM: 16.0.0
IOT2 ROM: 16.0.0
Panel ROM: 1.0.4
SJFI: 6.1.0
SSMI: 3.3.0
Contents: 6.11.3
Plugin: 6.11.2
Plugin platform: 3.1.0
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI (Maintained) : Not supported.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow.
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Payment System
After authentication, it can take 20 ~ 30 before a user lands on the home.(To be investigated)
|
||
FUJIFILM BI | ApeosPrint C3530 | ApeosPrint | No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device
Apeos C4430
This model supports only Apeos IntegrationPlus 7(AIP7).
System: 22.10.21
Controller ROM: 1.20.5
IOT ROM: 16.0.0
IOT2 ROM: 16.0.0
Panel ROM: 1.0.4
SJFI: 6.1.0
SSMI: 3.3.0
Contents: 6.11.3
Plugin: 6.11.2
Plugin platform: 3.1.0
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI (Maintained) : Not supported.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow.
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Printing
Japan model does not support PCL
Payment System
After authentication, it can take 20 ~ 30 before a user lands on the home.(To be investigated)
|
||
FUJIFILM BI | ApeosPrint C4030 | ApeosPrint | No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device
Apeos C4430
This model supports only Apeos IntegrationPlus 7(AIP7).
System: 22.10.21
Controller ROM: 1.20.5
IOT ROM: 16.0.0
IOT2 ROM: 16.0.0
Panel ROM: 1.0.4
SJFI: 6.1.0
SSMI: 3.3.0
Contents: 6.11.3
Plugin: 6.11.2
Plugin platform: 3.1.0
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI (Maintained) : Not supported.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow.
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Printing
Japan models support ART EX only with PS3 as optional addon.
Payment System
After authentication, it can take 20 ~ 30 before a user lands on the home.(To be investigated)
|
||
FUJIFILM BI | ApeosPrint 3360 S | ApeosPrint | No |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
The model does not support Embedded Terminal technology
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
|
||
FUJIFILM BI | ApeosPrint 3960 S | ApeosPrint | No |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
The model does not support Embedded Terminal technology
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
|
||
FUJIFILM BI | ApeosPrint 4560 S | ApeosPrint | No |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
The model does not support Embedded Terminal technology
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
|
||
FUJIFILM BI | Apeos C2570 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Information about the tested device(AIP6)
ApeosPort C7070
System: 20.4.3
Controller ROM: 1.0.2
SJFI: 5.0.0
SSMI: 2.104.0
Plugin: 4.7.2
General
XCP Terminal requires FW1.1.101 or newer.
SafeQ5
XCP Terminal requires SafeQ5 MU65 or newer.
SafeQ6
Build29 ~ MU75 - XCP Terminal requires SafeQ6 MU29 or newer.
Build76 and newer - Should choose FUJI XEROX(Maintained) when installing Terminal Embedded.
Installation and uninstallation
Installation requires following manual configuration
(Admin login > System > Plug-in Settings > Toggle “Signature Verification when Adding/Updating” to disabled )
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstall XCP Terminal requires FW1.1.13. Older FW requires the manual steps bellow.
Open CentreWare Internet Services. Go to "Properties" Tab -> Security -> Authentication
Configuration -> Login Type. Set to "No Login Required".
Apply -> Reboot
After rebooting, Delete a device on SafeQ 6 Management Interface.
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Payment System
(XCP plugin terminal) Stop on Zero with the Payment System requires FW1.1.13 or newer.
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos 5580 | Apeos | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device
Apeos 5580
This model supports only Apeos IntegrationPlus 7(AIP7).
System: 22.6.10
Controller ROM: 1.0.7
IOT ROM: 56.7.0
SJFI: 6.1.0
SSMI: 3.2.0
Contents: 5.15.30
Plugin: 5.15.30
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI (Maintained) : Not supported.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow.
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Printing
Japan model does not support PCL
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos 6580 | Apeos | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device
Apeos 5580
This model supports only Apeos IntegrationPlus 7(AIP7).
System: 22.6.10
Controller ROM: 1.0.7
IOT ROM: 56.7.0
SJFI: 6.1.0
SSMI: 3.2.0
Contents: 5.15.30
Plugin: 5.15.30
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI (Maintained) : Not supported.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow.
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Printing
Japan model does not support PCL
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos 7580 | Apeos | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device
Apeos 5580
This model supports only Apeos IntegrationPlus 7(AIP7).
System: 22.6.10
Controller ROM: 1.0.7
IOT ROM: 56.7.0
SJFI: 6.1.0
SSMI: 3.2.0
Contents: 5.15.30
Plugin: 5.15.30
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI (Maintained) : Not supported.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow.
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Printing
Japan model does not support PCL
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | ApeosPrint C4570 | ApeosPrint | No |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device
ApeosPrint C5570
System: 22.6.10
Controller ROM: 1.0.7
IOT ROM: 56.7.0
Panel ROM: 0.0.2
SJFI: 6.1.0
SSMI: 3.2.0
Contents: 5.15.30
Plugin: 5.15.30
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | ApeosPrint C5570 | ApeosPrint | No |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device
ApeosPrint C5570
System: 22.6.10
Controller ROM: 1.0.7
IOT ROM: 56.7.0
Panel ROM: 0.0.2
SJFI: 6.1.0
SSMI: 3.2.0
Contents: 5.15.30
Plugin: 5.15.30
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos 1860 | Apeos | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3060
System: 21.10.26
Controller ROM: 1.0.5
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.5.25
Plugin: 5.5.24
Information about the tested device (AIP7)
Not yet tested
Genera
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C2360 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3060
System: 21.10.26
Controller ROM: 1.0.5
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.5.25
Plugin: 5.5.24
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos 3570 | Apeos | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device (AIP6)
This model is certified based on Apeos C3570, C6580, ApeosPro C650
Apeos C3570
Apeos C6580
ApeosPro C650
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.0.7
Plugin: 5.0.8
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.1.7
Plugin: 5.1.8
System: 21.6.10
Controller ROM: 1.0.24
SJFI: 6.0.1
SSMI: 3.0.0
Contents: 5.2.10
Plugin: 5.2.11
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos 4830 | Apeos | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI (Maintained) : Not supported.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow.
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Payment System
Login speed improvement with Payment System is planned for build 77
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | ApeosPrint C5240 | ApeosPrint | No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
ApeosPrint C5240
System: 21.11.29
Controller ROM: 1.0.6
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.8.25
Plugin: 5.8.23
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | ApeosPrint 6340 | ApeosPrint | No |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3060
ApeosPrint C5240
System: 21.10.26
Controller ROM: 1.0.5
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.5.25
Plugin: 5.5.24
System: 21.11.29
Controller ROM: 1.0.6
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.8.25
Plugin: 5.8.23
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos 6340 | Apeos | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3060
ApeosPrint C5240
System: 21.10.26
Controller ROM: 1.0.5
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.5.25
Plugin: 5.5.24
System: 21.11.29
Controller ROM: 1.0.6
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.8.25
Plugin: 5.8.23
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C5240 | Apeos | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3060
ApeosPrint C5240
System: 21.10.26
Controller ROM: 1.0.5
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.5.25
Plugin: 5.5.24
System: 21.11.29
Controller ROM: 1.0.6
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.8.25
Plugin: 5.8.23
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos 2560 | Apeos | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3060
System: 21.10.26
Controller ROM: 1.0.5
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.5.25
Plugin: 5.5.24
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos 3060 | Apeos | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3060
System: 21.10.26
Controller ROM: 1.0.5
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.5.25
Plugin: 5.5.24
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos 3560 | Apeos | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3060
System: 21.10.26
Controller ROM: 1.0.5
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.5.25
Plugin: 5.5.24
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C2060 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3060
System: 21.10.26
Controller ROM: 1.0.5
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.5.25
Plugin: 5.5.24
Information about the tested device(AIP6)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C2560 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3060
System: 21.10.26
Controller ROM: 1.0.5
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.5.25
Plugin: 5.5.24
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C3060 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3060
System: 21.10.26
Controller ROM: 1.0.5
SJFI: 6.0.1
SSMI: 3.1.0
Contents: 5.5.25
Plugin: 5.5.24
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos 4570 | Apeos | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device (AIP6)
This model is certified based on Apeos C3570, C6580, ApeosPro C650
Apeos C3570
Apeos C6580
ApeosPro C650
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.0.7
Plugin: 5.0.8
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.1.7
Plugin: 5.1.8
System: 21.6.10
Controller ROM: 1.0.24
SJFI: 6.0.1
SSMI: 3.0.0
Contents: 5.2.10
Plugin: 5.2.11
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos 5570 | Apeos | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device (AIP6)
This model is certified based on Apeos C3570, C6580, ApeosPro C650
Apeos C3570
Apeos C6580
ApeosPro C650
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.0.7
Plugin: 5.0.8
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.1.7
Plugin: 5.1.8
System: 21.6.10
Controller ROM: 1.0.24
SJFI: 6.0.1
SSMI: 3.0.0
Contents: 5.2.10
Plugin: 5.2.11
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | ApeosPro C650 | ApeosPro | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
ApeosPro C650
System: 21.6.10
Controller ROM: 1.0.24
SJFI: 6.0.1
SSMI: 3.0.0
Contents: 5.2.10
Plugin: 5.2.11
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | ApeosPro C750 | ApeosPro | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
ApeosPro C650
System: 21.6.10
Controller ROM: 1.0.24
SJFI: 6.0.1
SSMI: 3.0.0
Contents: 5.2.10
Plugin: 5.2.11
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | ApeosPro C810 | ApeosPro | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
ApeosPro C650
System: 21.6.10
Controller ROM: 1.0.24
SJFI: 6.0.1
SSMI: 3.0.0
Contents: 5.2.10
Plugin: 5.2.11
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C3070 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3570
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.0.7
Plugin: 5.0.8
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C3570 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3570
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.0.7
Plugin: 5.0.8
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C4570 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3570
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.0.7
Plugin: 5.0.8
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Printing
Japan model does not support PCL
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C5570 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3570
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.0.7
Plugin: 5.0.8
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Printing
Japan model does not support PCL
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C6570 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3570
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.0.7
Plugin: 5.0.8
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C7070 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C3570
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.0.7
Plugin: 5.0.8
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Printing
Japan model does not support PCL
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C7580 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C6580
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.1.7
Plugin: 5.1.8
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C6580 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C6580
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.1.7
Plugin: 5.1.8
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Revoria Press SC170 | Revoria Press | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
Information about the tested device
Press SC180, Revoria Press SC170
ESS: 1.0.1
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI (Maintained) : Not supported.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow.
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Payment System
Login speed improvement with Payment System is planned for build 77
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Revoria Press SC180 | Revoria Press | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device
Press SC180, Revoria Press SC170
ESS: 1.0.1
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI (Maintained) : Not supported.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow.
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
LIMIT-177 Online accounting via IPP may incorrectly account jobs with duplex and blank pages.
Payment System
Login speed improvement with Payment System is planned for build 77
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Revoria Press E1100 | Revoria Press | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
This model is certified based on Apeos C3570, C6580, ApeosPro C650
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Revoria Press E1110 | Revoria Press | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
This model is certified based on Apeos C3570, C6580, ApeosPro C650
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Revoria Press E1125 | Revoria Press | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
This model is certified based on Apeos C3570, C6580, ApeosPro C650
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Revoria Press E1136 | Revoria Press | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
This model is certified based on Apeos C3570, C6580, ApeosPro C650
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | Apeos C8180 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Information about the tested device(AIP6)
Apeos C6580
System: 21.3.30
Controller ROM: 1.0.20
SJFI: 6.0.0
SSMI: 3.0.0
Contents: 5.1.7
Plugin: 5.1.8
Information about the tested device (AIP7)
Not yet tested
General
SafeQ5
Not supported
SafeQ6
TE using AIP6 - FUJIFILM BI : Supported from build 63 and newer. Global model does not support this option.
TE using AIP6 - FUJIFILM BI (Maintained) : Supported from build 76 and newer. Should choose FUJIFILM BI(Maintained) when installing Terminal Embedded. Global model does not support this option.
TE using AIP7 - FUJIFILM BI (Active) : Supported from build 76 and newer. Should choose FUJIFILM BI (Active) when installing Terminal Embedded.
Installation
Global model
Make sure to select FUJIFILM BI (Active) for installation.
Nothing needs to be changed about Web Browser application version. Global model does not have a configuration option to change Browser application version and it supports only v5 Web browser.
APAC model
TE using AIP6 - Make sure that the embedded browser version is set to v4. (Admin login > Apps > Web Browser Setup).
TE using AIP7 - Make sure that the embedded browser version is set to v5. (Admin login > Apps > Web Browser Setup).
Common
If installing/reinstalling terminal fail when device takes longer than 35 seconds for rebooting, change the value of the parameter "FujiXeroxFinishRebootDelay" to longer value like 60.
Uninstallation (FUJIFILM BI (Active) - TE using AIP7)
After uninstallation, manually disabling Custom Authentication is required (current limitation).
(Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Authentication
When installing a terminal with authentication method without card swipe (PIN, Username and password), disable and disconnect the card reader else authentication becomes slow. (Admin login > Permissions > Authentication/Accounting Settings > Advanced Settings > Use of IC Card : Off)
Color copy access control
To restrict access to Full-color copy by the user access right setting, it requires the following setting.
Log in to the device as Administrator -> Permissions > Permissions > Access Control and set Color Copying to Locked and click Save.
Fax access control
If you want to restrict access to FAX application by the user access right, it requires "850-015" to be set to "1" in the CE mode.
Accounting
Print job accounting requires “701-436” to be set to “0” in the CE mode.
Scan control by Payment System
If you want to manage scan by credit/quota, it requires "850-015" to be set to "1" in the CE mode.
|
||
FUJIFILM BI | ApeosPort C4730SD | ApeosPort | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|
||
FUJIFILM BI | C7773 R, C6673R, C5573 R, C4473 R, C3373 R, C2273 R | ApeosPort-VII | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Since SAFEQ 6 build 76, choose FUJI XEROX XCP(Maintained) for installation. |
||
FUJIFILM BI | C7071, C6571, C5571, C4571, C3571, C3071, C2571 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
Supported from SAFEQ 6 build 76 and newer. Should choose FUJIFILM BI (Active) for installation. |
||
FUJIFILM BI | C3061, C2561, C2061 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
Supported from SAFEQ 6 build 76 and newer. Should choose FUJIFILM BI (Active) for installation. |
||
FUJIFILM BI | C3567, C3067, C2567 | Apeos | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
Supported from SAFEQ 6 build 76 and newer. Should choose FUJIFILM BI (Active) for installation. |
||
FUJIFILM BI | C7771 RC, C6671 RC, C5571 RC, C4471 RC, C3371R, C2271 RC | ApeosPort-VI | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Since SAFEQ 6 build 76, choose FUJI XEROX XCP(Maintained) for installation. |
||
FUJIFILM BI | ApeosPort Print 4730SD | ApeosPort Print | No |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|
||
FUJIFILM BI | ApeosPort 4020SD | ApeosPort | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
Compact A4 Monochrome MFP with no support for embedded terminal. |
||
FUJIFILM BI | ApeosPort Print 4020SD | ApeosPort Print | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
A4 Mono Laser Printer with no support for embedded terminal. |
||
Gestetner | MP 2550 | Russian-C5c | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Gestetner | MP 2352SP | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Gestetner | E67650 | Color LaserJet MFP | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
|||
Gestetner | DSM 765 | Yes |
Yes |
No |
Yes |
Yes |
GESTETNER-GWCOLOR_MFP4 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Gestetner | DSM 735G | Yes |
No |
No |
Yes |
Yes |
GESTETNER-GWBW_MFP3 | No |
No |
Recommended driver:GESTETNER-GWBW_MFP3 Limitations:Duplex for printing is detected from job, copy duplex is using duplex counter. There is 4 seconds timeout after copy. Driver can be set for offline accounting. | No |
Untested |
No |
No |
No |
No |
||
Gestetner | DSM 735 | Yes |
No |
No |
Yes |
Yes |
GESTETNER-GWBW_MFP3 | No |
No |
Recommended driver:GESTETNER-GWBW_MFP3 Limitations:Duplex for printing is detected from job, copy duplex is using duplex counter. There is 4 seconds timeout after copy. Driver can be set for offline accounting. | No |
Untested |
No |
No |
No |
No |
||
Gestetner | DSM 615 | Yes |
No |
No |
Yes |
Yes |
GESTETNER-GWBW_MFP1 | No |
No |
Recommended driver:GESTETNER-GWBW_MFP1 Limitations:There is 4 seconds timeout after copy. Driver can be set for offline accounting. | No |
Untested |
No |
No |
No |
No |
||
Gestetner | DSM 7110 | Yes |
Yes |
No |
Yes |
Yes |
GESTETNER-GWCOLOR_MFP4 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Gestetner | DSM MP 1100 | Yes |
Yes |
No |
Yes |
Yes |
GESTETNER-GWCOLOR_MFP4 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Gestetner | C7535N | No |
Yes |
Yes |
Yes |
Yes |
GESTETNER-GWCOLOR_PRN4 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Gestetner | C7526DN | No |
No |
Yes |
Yes |
Yes |
GESTETNER-GWCOLOR_PRN5 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Gestetner | MP C3501 | MP | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480) JAVA VM Card is a standard part of the device. Settings for 4-pin blocking cable: 5-113-1 set to 0, 5-113-2 set to 1.
|
||
Gestetner | MP C3001 | MP | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480) JAVA VM Card is a standard part of the device. Settings for 4-pin blocking cable: 5-113-1 set to 0, 5-113-2 set to 1.
|
||
Gestetner | MP 5000 Series | Alex C1c | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Gestetner | MP 4000 Series | Alex C1b | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
HP | Color LaserJet Managed 55040DN | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
Not tested - Embedded terminal should works based on used technology
|
|||
HP | LaserJet 73030 | GEMSTONE 2.0 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Yes |
No |
No |
No |
No |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
|
||
HP | LaserJet 73025 | GEMSTONE 2.0 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Yes |
No |
No |
No |
No |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
|
||
HP | E78625 | Color LaserJet Managed Flow MFP | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
- Also known as HP Color LaserJet Managed MFP E786dn
- Also fits for Flow version Color LaserJet Flow E878625 or Color LaserJet Managed Flow MFP E786z
|
||
HP | Color LaserJet Managed MFP E77422 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and MU20 required EAP license
FW bundle version 4.6.0.1 and later required for USB readers
|
|||
HP | LaserJet Managed MFP E72425 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and MU20 required EAP license
FW bundle version 4.6.0.1 and later required for USB readers
|
|||
HP | E78330 | E783xx series | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | E78325 | E783xx series | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | E78323 | E783xx series | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet Pro M404 | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
HP | HP LaserJet Managed E60155dn | No |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Printer only, Scan application not supported.
Firmware bundle 4.6.0.1 and later required for USB reader support.
4.3 inch display required.
|
|||
HP | LaserJet Managed E50145dn | No |
No |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
* FW bundle version 4.6.0.1 and later required for USB readers
|
|||
HP | N9120 fn2 | ScanJet | No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU19 and MU20 require EAP license.
FW bundle version 4.6.0.1 and later required for USB readers.
After Embedded Terminal installation print application should be hidden from the device web.
|
||
HP | Digital Sender Flow 8500 fn2 | Digital Sender Flow | No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
YSoft SafeQ 6 MU19 and MU20 require EAP license.
FW bundle version 4.6.0.1 and later required for USB readers.
After Embedded Terminal installation print application should be hidden from the device web.
scanServerType SafeQ property has to be "WebDAV, FTP".
|
||
HP | PageWide Flow MFP 785 series | MFP 780 series | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | PageWide MFP 780 series | MFP 780 series | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet E52545 | Yes |
No |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
||||
HP | Laserjet Pro 200 M276 | LaserJet | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet Pro MFP M126 series | Yes |
No |
No |
Yes |
No |
No |
No |
Request: SAFEQ-35466 Offline accounting is supported.* All devices (incl. devices FALSEt covered by the list) are compatible with YSoft SafeQ offline accounting provided they support PCL, Post Script or HPGL print language. | No |
Untested |
No |
No |
No |
No |
|||
HP | T2500 | DesignJet | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Request: SAFEQ-33643Beta driver available for certifiation: OFFLINE-PLOTTER Limitations:Accounting method of this driver is similar to Offline accounting method in SafeQ.Driver uses coverage accounting to account paper formats larger than A3 in multiples of A4.A2/A1/A0 accounted as 4/8/16x A4.Jobs are accounted according to information from parser (Jobs that are cancelled on device during print are accounted).Print driver (FALSEt SafeQ accouting driver) have to support PCL, HPGL or PostScript print language.Enable rendering jobs as high-resolution (150 DPI) images to use this driver.Copy and scan jobs are FALSEt accounted. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet CP1518ni | LaserJet | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | Color LaserJet CP1515n | LaserJet | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | Color LaserJet Enterprise MFP M680z | LaserJet | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Request: YSOFT-2014-21841, YSOFT-2014-22409 Offline accounting is supported.* All devices (incl. devices FALSEt covered by the list) are compatible with YSoft SafeQ offline accounting provided they support PCL, Post Script or HPGL print language. Blocking interface limitations:Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
No |
Yes |
||
HP | Color LaserJet Enterprise MFP M680f | LaserJet | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Request: YSOFT-2014-21841, YSOFT-2014-22409 Offline accounting is supported.* All devices (incl. devices FALSEt covered by the list) are compatible with YSoft SafeQ offline accounting provided they support PCL, Post Script or HPGL print language. Blocking interface limitations:Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
No |
Yes |
||
HP | Color LaserJet Enterprise MFP M680dn | LaserJet | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
Request: YSOFT-2014-21841, YSOFT-2014-22409 Offline accounting is supported.* All devices (incl. devices FALSEt covered by the list) are compatible with YSoft SafeQ offline accounting provided they support PCL, Post Script or HPGL print language. Blocking interface limitations:Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
No |
Yes |
||
HP | Officejet Pro 276dw | OfficeJet | Yes |
No |
Yes |
Yes |
No |
No |
No |
Request: YSOFT-2014-18718 Offline accounting is supported.* All devices (incl. devices FALSEt covered by the list) are compatible with YSoft SafeQ offline accounting provided they support PCL, Post Script or HPGL print language. | No |
Untested |
No |
No |
No |
No |
||
HP | Officejet Pro 251dw | OfficeJet | No |
No |
Yes |
Yes |
No |
No |
No |
Request: YSOFT-2014-18717 Offline accounting is supported.* All devices (incl. devices FALSEt covered by the list) are compatible with YSoft SafeQ offline accounting provided they support PCL, Post Script or HPGL print language. | No |
Untested |
No |
No |
No |
No |
||
HP | Officejet Pro 8600 | OfficeJet | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | Color LaserJet CM1312 | OfficeJet | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet Pro P1606dn | No |
No |
No |
Yes |
No |
No |
No |
Device is FALSEt compatible with SafeQ online accouting method. Only offline accounting is possible. Job sent via Host-Based Driver are FALSEt accepted by SafeQ.Only exception (working set up) is Host-Based Driver installed on Windows 7 OS. Jobs are accepted by SafeQ when job is sent via Advanced TCP/IP Port instead of Standard TCP/IP Port.Advanced TCP/IP Port is avialable after installation of HP print driver for Windows. | No |
Untested |
No |
No |
No |
No |
|||
HP | Color LaserJet CM6049 | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
HP | LaserJetP2035n | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
HP | LaserJet M4349 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
HP | LaserJet2420dn | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
HP | Color LaserJet 2605 | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
HP | Color LaserJet2600n | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
HP | Officejet Pro X551dw | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
HP | E73025 | LaserJet Managed MFP | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
No |
Untested |
No |
Yes |
No |
Yes |
|||
HP | Color LaserJet MFP E785 Series | Color LaserJet Managed | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
HP | E62675 | LaserJet Flow MFP | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
No |
Untested |
No |
Yes |
No |
Yes |
|||
HP | E67660 | Color LaserJet Flow | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
|||
HP | E57540 | Color LaserJet Flow | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
|||
HP | X67765 | Color LaserJet Enterprise Flow MFP | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
|||
HP | X67755 | Color LaserJet Enterprise MFP | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
|||
HP | X58045 | Color LaserJet Enterprise MFP | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
|||
HP | X57945 | Color LaserJet Enterprise Flow MFP | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
|||
HP | Color LaserJet Enterprise X654 | No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
Workpath Gen 2 terminal is not supported due to 4.3" display limitation
|
|||
HP | Color LaserJet Enterprise 6701 | No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
Workpath Gen 2 terminal is not supported due to 4.3" display limitation
|
|||
HP | Color LaserJet Enterprise 5700 | No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
Workpath Gen 2 terminal is not supported due to 4.3" display limitation
|
|||
HP | Color LaserJet Enterprise 6700 | No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
Workpath Gen 2 terminal is not supported due to 4.3" display limitation.
|
|||
HP | 6801 | Color LaserJet Enterprise MFP | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
|||
HP | X677 | Color LaserJet Enterprise MFP | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
|||
HP | 6800 | Color LaserJet Enterprise MFP | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
|||
HP | Color LaserJet Enterprise MFP 5800 | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
||||
HP | M528 | LaserJet Flow MFP | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
HP | 552dw | PageWide Pro | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M451DN | No |
No |
Recommended driver: HP-PRN-COL-A4-M451DN Limitations: When the device runs out of paper during print, jobs are accounted after the paper is refilled. | No |
Untested |
No |
No |
No |
No |
|
HP | 452dw | PageWide Pro | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M451DN | No |
No |
Recommended driver: HP-PRN-COL-A4-M451DN Limitations: When the device runs out of paper during print, jobs are accounted after the paper is refilled. | No |
Untested |
No |
No |
No |
No |
|
HP | 452dn | PageWide Pro | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M451DN | No |
No |
Recommended driver: HP-PRN-COL-A4-M451DN Limitations: When the device runs out of paper during print, jobs are accounted after the paper is refilled. | No |
Untested |
No |
No |
No |
No |
|
HP | LaserJet Managed E52645 | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
- YSoft SafeQ 6 MU19 and MU20 require EAP license.
- FW bundle version 4.6.0.1 and later required for USB readers.
- After Embedded Terminal installation print application should be hidden from the device web.
|
|||
HP | LaserJet Enterprise M806 | LaserJet | No |
Yes |
No |
Yes |
No |
HP-PRN-BW-A3-M712 | No |
No |
Recommended driver: HP-PRN-BW-A3-M712 Limitations: All counters start with 1. | No |
Untested |
No |
No |
No |
No |
|
HP | Color LaserJet M855 | LaserJet | No |
Yes |
Yes |
Yes |
No |
HP-PRN-COL-A3-M855 | No |
No |
Recommended driver: HP-PRN-COL-A3-M855 Limitations: If device runs out of paper during print/copy, counter differences may occur. There is a 3 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
FutureSmart 4 firmware required.
|
HP | PageWide MFP 586 | PageWide | Yes |
No |
Yes |
Yes |
No |
HP-MFP-COL-A4-586 | No |
No |
Recommended driver: HP-MFP-COL-A4-586 Limitations: Counters for copy and print are shared. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader supported with firmware version bundle 4.6.0.1 and later.
|
HP | LaserJet Enterprise MFP M630 series | LaserJet | Yes |
No |
No |
Yes |
Yes |
HP-MFP-BW-A4-M630 | No |
No |
Recommended driver: HP-MFP-BW-A4-M630 Limitations: Counters for copy and print are shared. All counters start with 1. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
USB reader supported only with FutureSmart 3
|
HP | LaserJet Enterprise 700 M712xh | LaserJet | No |
Yes |
No |
Yes |
No |
HP-PRN-BW-A3-M712 | No |
No |
Recommended driver:HP-PRN-BW-A3-M712 Limitations:All counters start with 1. | No |
Untested |
No |
No |
No |
No |
|
HP | LaserJet Enterprise 700 M712dn | LaserJet | No |
Yes |
No |
Yes |
No |
HP-PRN-BW-A3-M712 | No |
No |
Recommended driver:HP-PRN-BW-A3-M712 Limitations:All counters start with 1. | No |
Untested |
No |
No |
No |
No |
|
HP | LaserJet Enterprise 700 M712n | LaserJet | No |
Yes |
No |
Yes |
No |
HP-PRN-BW-A3-M712 | No |
No |
Recommended driver:HP-PRN-BW-A3-M712 Limitations:All counters start with 1. | No |
Untested |
No |
No |
No |
No |
|
HP | Color LaserJet X585 | OfficeJet | Yes |
No |
Yes |
Yes |
Yes |
HP-MFP-COL-A4-X585 | No |
No |
Recommended driver:HP-MFP-COL-A4-X585 Limitations:Counters for copy and print are shared.All counters start with 1. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
|
HP | Color LaserJet M521 | LaserJet | Yes |
No |
No |
Yes |
No |
HP-MFP-BW-A4-M425 | No |
No |
Recommended driver: HP-MFP-BW-A4-M425 Limitations:Counters for copy and print are shared.SafeQ 3.6: autodetection is FALSEt supported for LaserJet Pro MFP M521dw.There is a 4 seconds timeout after copy.If device runs out of paper during print/copy, job is accounted after paper is refilled. | No |
Untested |
No |
No |
No |
No |
|
HP | Color LaserJet M750 | LaserJet | No |
Yes |
Yes |
Yes |
No |
HP-PRN-COL-A3-M750 | No |
No |
Recommended driver:HP-PRN-COL-A3-M750 Limitation: There is a 10 seconds timeout after print. All counters start with 1. | No |
Untested |
No |
No |
No |
No |
|
HP | LaserJet Enterprise MFP M830z | LaserJet | Yes |
Yes |
No |
Yes |
Yes |
HP-MFP-BW-A3-M830 | No |
No |
Recommended driver: HP-MFP-BW-A3-M830 Limitation: Counters for copy and print are shared. All counters start with 1. Blocking interface limitations: Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
|
HP | LaserJet Enterprise Flow MFP M880 Series | LaserJet Enterprise Flow | Yes |
Yes |
Yes |
Yes |
Yes |
HP-MFP-COL-A3-M880 | No |
Yes |
Recommended driver: HP-MFP-COL-A3-M880 Limitation: Counters for copy and print are shared. All counters start with 1. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
|
HP | P4510 | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | P4014 | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | P4010 | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | CP4525n | LaserJet | No |
No |
Yes |
Yes |
No |
HP-COL-DUP-CP4525N | No |
No |
No |
Untested |
No |
No |
No |
No |
||
HP | CP4025n | LaserJet | No |
No |
Yes |
Yes |
No |
HP-COL-DUP-CP4525N | No |
No |
No |
Untested |
No |
No |
No |
No |
||
HP | CP4020 | LaserJet | No |
No |
Yes |
Yes |
No |
HP-COL-DUP-CP4525 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
HP | M451nw | LaserJet 400 | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M451NW | No |
No |
Recommended driver: HP-PRN-COL-A4-M451NW Limitations: When the device runs out of paper during print, jobs are accounted after the paper is refilled. | No |
Untested |
No |
No |
No |
No |
|
HP | M451dw | LaserJet 400 | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M451DN | No |
No |
Recommended driver: HP-PRN-COL-A4-M451DN Limitations: When the device runs out of paper during print, jobs are accounted after the paper is refilled. | No |
Untested |
No |
No |
No |
No |
|
HP | M451dn | LaserJet 400 | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M451DN | No |
No |
Recommended driver: HP-PRN-COL-A4-M451DN Limitations: When the device runs out of paper during print, jobs are accounted after the paper is refilled. | No |
Untested |
No |
No |
No |
No |
|
HP | LaserJet Enterprise MFP M725 | LaserJet Enterprise | Yes |
Yes |
No |
Yes |
Yes |
HP-MFP-BW-A3-M725 | No |
Yes |
Recommended driver: HP-MFP-BW-A3-M725 Limitations: Counters for copy and print are shared. All counters start with 1. Blocking interface limitations: Only copy function can be blocked via FIH port. | No |
Yes |
No |
No |
Yes |
Yes |
|
HP | OfficeJet Pro X451dn | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
HP | ColorLaserJet Pro CP6015xh | No |
Yes |
Yes |
Yes |
No |
HP-PRN-COL-A3-CP6015N | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet Pro 200 M251n | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M251N | No |
No |
Recommended driver:HP-PRN-COL-A4-M251N Limitations:When the device runs out of paper during print, jobs are accounted after the paper is refilled. There is a 1 second timeout after print. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 5200 | No |
Yes |
No |
Yes |
No |
HP-A3-DUP | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet M2727nf | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
No blocking available.
|
|||
HP | LaserJet Pro CM1415fnw | Yes |
No |
Yes |
Yes |
No |
HP-MFP-COL-A4-CM1415FN | No |
No |
Recommended driver:HP-MFP-COL-A4-CM1415FN Limitations:If the device runs out of paper during print/copy and the paper is refilled, jobs are accounted after the paper is refilled. | No |
Untested |
No |
No |
No |
No |
||
HP | DesignJet | No |
No |
No |
Yes |
No |
OFFLINE-PLOTTER | No |
No |
Recommended driver:OFFLINE-PLOTTER Limitations:Please enable rendering jobs as high-resolution (150 DPI) images to use this driver.This driver uses coverage accounting to account paper formats larger than A3 in multiples of A4. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet Pro CP1525n | No |
No |
Yes |
Yes |
No |
HP-COL-1525N | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | Color LaserJet 5550dn | No |
Yes |
Yes |
Yes |
No |
HP-COL-A3 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | Color LaserJet CP5525dn | No |
Yes |
Yes |
Yes |
No |
HP-PRN-COL-A3-CP5520 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | Color LaserJet CP5520n | No |
Yes |
Yes |
Yes |
No |
HP-PRN-COL-A3-CP5520 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | Color LaserJet CP3505 | No |
No |
Yes |
Yes |
No |
HP-COL-PRT | No |
No |
Recommended driver:HP-COL-PRT Limitations:Duplex print is accounted according to parser from job information.Driver may cause device locks in case of low toner. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet CM3530 | Yes |
No |
Yes |
Yes |
Yes |
HP-COL-A4-MFP-3530fs-V3 | No |
No |
Recommended driver:HP-COL-A4-MFP-3530fs-V3 Limitations:There is a 8 second timeout after print. There is a 8 second timeout after copy. Counters for copy and print are shared. Driver makes accounting all formats of papers as A4. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet P4015 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 700 Managed MFP M775zm | Yes |
Yes |
Yes |
Yes |
Yes |
HP-MFP-COL-A3-DUP-LJ700C-M775 | No |
No |
Recommended driver: HP-MFP-COL-A3-DUP-LJ700C-M775 Limitations: Counters for copy and print are shared. There is 13 seconds timeout after print. There is 13 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
USB reader supported with FutureSmart 3 and FutureSmart 4 firmware bundle 4.6.0.1 and later
|
|
HP | LaserJet 700 Managed MFP M775fm | Yes |
Yes |
Yes |
Yes |
Yes |
HP-MFP-COL-A3-DUP-LJ700C-M775 | No |
No |
Recommended driver: HP-MFP-COL-A3-DUP-LJ700C-M775 Limitations: Counters for copy and print are shared. There is 13 seconds timeout after print. There is 13 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
USB reader supported with FutureSmart 3 and FutureSmart 4 firmware bundle 4.6.0.1 and later
|
|
HP | LaserJet 700 Enterprise M775zm | Yes |
Yes |
Yes |
Yes |
Yes |
HP-MFP-COL-A3-DUP-LJ700C-M775 | No |
No |
Recommended driver: HP-MFP-COL-A3-DUP-LJ700C-M775 Limitations: Counters for copy and print are shared. There is 13 seconds timeout after print. There is 13 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
USB reader supported with FutureSmart 3 and FutureSmart 4 firmware bundle 4.6.0.1 and later
|
|
HP | LaserJet 700 Enterprise M775fm | Yes |
Yes |
Yes |
Yes |
Yes |
HP-MFP-COL-A3-DUP-LJ700C-M775 | No |
No |
Recommended driver: HP-MFP-COL-A3-DUP-LJ700C-M775 Limitations: Counters for copy and print are shared. There is 13 seconds timeout after print. There is 13 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
USB reader supported with FutureSmart 3 and FutureSmart 4 firmware bundle 4.6.0.1 and later
|
|
HP | LaserJet 700 Enterprise M775z+ | Yes |
Yes |
Yes |
Yes |
Yes |
HP-MFP-COL-A3-DUP-LJ700C-M775 | No |
No |
Recommended driver: HP-MFP-COL-A3-DUP-LJ700C-M775 Limitations: Counters for copy and print are shared. There is 13 seconds timeout after print. There is 13 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
USB reader supported with FutureSmart 3 and FutureSmart 4 firmware bundle 4.6.0.1 and later
|
|
HP | LaserJet 700 Enterprise M775z | Yes |
Yes |
Yes |
Yes |
Yes |
HP-MFP-COL-A3-DUP-LJ700C-M775 | No |
No |
Recommended driver: HP-MFP-COL-A3-DUP-LJ700C-M775 Limitations: Counters for copy and print are shared. There is 13 seconds timeout after print. There is 13 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
USB reader supported with FutureSmart 3 and FutureSmart 4 firmware bundle 4.6.0.1 and later
|
|
HP | LaserJet 700 Enterprise M775f | Yes |
Yes |
Yes |
Yes |
Yes |
HP-MFP-COL-A3-DUP-LJ700C-M775 | No |
No |
Recommended driver: HP-MFP-COL-A3-DUP-LJ700C-M775 Limitations: Counters for copy and print are shared. There is 13 seconds timeout after print. There is 13 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
USB reader supported with FutureSmart 3 and FutureSmart 4 firmware bundle 4.6.0.1 and later
|
|
HP | LaserJet 700 Enterprise MFP M775dn | Yes |
Yes |
Yes |
Yes |
Yes |
HP-MFP-COL-A3-DUP-LJ700C-M775 | No |
No |
Recommended driver: HP-MFP-COL-A3-DUP-LJ700C-M775 Limitations: Counters for copy and print are shared. There is 13 seconds timeout after print. There is 13 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
USB reader supported with FutureSmart 3 and FutureSmart 4 firmware bundle 4.6.0.1 and later
|
|
HP | LaserJet M603 | No |
No |
No |
Yes |
No |
HP-PRN-BW-A4-M600 | No |
No |
Recommended driver: HP-PRN-BW-A4-M600 Limitations: There is a 1 second timeout after print. All counters start with 1. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet M602 | No |
No |
No |
Yes |
No |
HP-PRN-BW-A4-M600 | No |
No |
Recommended driver: HP-PRN-BW-A4-M600 Limitations: There is a 1 second timeout after print. All counters start with 1. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet M601 | No |
No |
No |
Yes |
No |
HP-PRN-BW-A4-M600 | No |
No |
Recommended driver: HP-PRN-BW-A4-M600 Limitations: There is a 1 second timeout after print. All counters start with 1. | No |
Untested |
No |
No |
No |
No |
||
HP | M1212nf MFP | Yes |
No |
No |
Yes |
No |
HP-MFP-M1212NF | No |
No |
Recommended driver:HP-MFP-M1212NF Limitations:Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
No blocking available.
|
|
HP | LaserJet P3015dn | No |
No |
No |
Yes |
No |
HP-PRN-BW-A4-LJ-P3015 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet P3010 Series | No |
No |
No |
Yes |
No |
HP-PRN-BW-A4-LJ-P3015 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | Color LaserJet CM4540 | Yes |
No |
Yes |
Yes |
Yes |
HP-MFP-COL-A4-CM4540 | No |
No |
Recommended driver: HP-MFP-COL-A4-CM4540 Limitations: There is a 10 seconds timeout after print. There is a 10 seconds timeout after copy. Counters for copy and print are shared. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 500 MFP M575 | Yes |
No |
Yes |
Yes |
Yes |
HP-MFP-COL-DUP-LJ_M575 | No |
No |
Recommended driver: HP-MFP-COL-DUP-LJ_M575 Limitations: Counters for copy and print are shared. There is a 6 second timeout after print. There is a 6 second timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
FW bundle version 4.6.0.1 and later required for USB readers
|
|
HP | LaserJet Enterprise M553x | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M551DN | No |
No |
Recommended driver: HP-PRN-COL-A4-M551DN Limitations: There is a 2 second timeout after print. All counters start with 1. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet Enterprise M553dn | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M551DN | No |
No |
Recommended driver: HP-PRN-COL-A4-M551DN Limitations: There is a 2 second timeout after print. All counters start with 1. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet Enterprise M553n | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M551DN | No |
No |
Recommended driver: HP-PRN-COL-A4-M551DN Limitations: There is a 2 second timeout after print. All counters start with 1. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet Enterprise M552dn | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M551DN | No |
No |
Recommended driver: HP-PRN-COL-A4-M551DN Limitations: There is a 2 second timeout after print. All counters start with 1. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 500 M551n | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M551DN | No |
No |
Recommended driver: HP-PRN-COL-A4-M551DN Limitations: There is a 2 second timeout after print. All counters start with 1. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 500 M551xh | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M551DN | No |
No |
Recommended driver: HP-PRN-COL-A4-M551DN Limitations: There is a 2 second timeout after print. All counters start with 1. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 500 M551dn | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-M551DN | No |
No |
Recommended driver: HP-PRN-COL-A4-M551DN Limitations: There is a 2 second timeout after print. All counters start with 1. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 500 MFP M525 | Yes |
No |
No |
Yes |
Yes |
HP-MFP-BW-A4-M525 | No |
No |
Recommended driver:HP-MFP-BW-A4-M525 Limitations:RA4 format is accounted as a large format.Large format counters start from 1.Counters for copy and print are shared.There is a 2 seconds timeout after print. Blocking interface limitations:Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
FW bundle version 4.6.0.1 and later required for USB readers
|
|
HP | LaserJet 300 MFP M375nw | Yes |
No |
Yes |
Yes |
No |
HP-MFP-COL-A4-M375 | No |
No |
Recommended driver:HP-MFP-COL-A4-M375 Limitations:There is a 5 seconds timeout after copy.Device canFALSEt be blocked.Driver can be set for offline copy accounting. | No |
Untested |
No |
No |
No |
No |
||
HP | Officejet Pro 476dw MFP | Yes |
No |
Yes |
Yes |
No |
HP-MFP-COL-A4-M475 | No |
No |
Recommended driver:HP-MFP-COL-A4-M475 Limitations:Counters for copy and print are shared.When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled.There is a 5 seconds timeout after copy.Device canFALSEt be blocked. | No |
Untested |
No |
No |
No |
No |
||
HP | Officejet Pro X476dn MFP | Yes |
No |
Yes |
Yes |
No |
HP-MFP-COL-A4-M475 | No |
No |
Recommended driver:HP-MFP-COL-A4-M475 Limitations:Counters for copy and print are shared.When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled.There is a 5 seconds timeout after copy.Device canFALSEt be blocked. | No |
Untested |
No |
No |
No |
No |
||
HP | Officejet Pro X576dw MFP | Yes |
No |
Yes |
Yes |
No |
HP-MFP-COL-A4-M475 | No |
No |
Recommended driver:HP-MFP-COL-A4-M475 Limitations:Counters for copy and print are shared.When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled.There is a 5 seconds timeout after copy.Device canFALSEt be blocked. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 400 MFP M475dw | Yes |
No |
Yes |
Yes |
No |
HP-MFP-COL-A4-M475 | No |
No |
Recommended driver:HP-MFP-COL-A4-M475 Limitations:Counters for copy and print are shared.When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled.There is a 5 seconds timeout after copy.Device canFALSEt be blocked. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 400 MFP M475dn | Yes |
No |
Yes |
Yes |
No |
HP-MFP-COL-A4-M475 | No |
No |
Recommended driver:HP-MFP-COL-A4-M475 Limitations:Counters for copy and print are shared.When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled.There is a 5 seconds timeout after copy.Device canFALSEt be blocked. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet Pro 400 MFP M425dn | No |
No |
No |
Yes |
No |
HP-MFP-BW-A4-M425 | No |
No |
Recommended driver: HP-MFP-BW-A4-M425 Limitations:Counters for copy and print are shared.SafeQ 3.6: autodetection is FALSEt supported for LaserJet Pro MFP M521dw.There is a 4 seconds timeout after copy.If device runs out of paper during print/copy, job is accounted after paper is refilled. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 400 M425dw | No |
No |
No |
Yes |
No |
HP-MFP-BW-A4-M425 | No |
No |
Recommended driver: HP-MFP-BW-A4-M425 Limitations:Counters for copy and print are shared.SafeQ 3.6: autodetection is FALSEt supported for LaserJet Pro MFP M521dw.There is a 4 seconds timeout after copy.If device runs out of paper during print/copy, job is accounted after paper is refilled. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 400 M401dw | No |
No |
No |
Yes |
No |
HP-PRN-BW-A4-M401 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet 400 M401dn | No |
No |
No |
Yes |
No |
HP-PRN-BW-A4-M401 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet 400 M401n | No |
No |
No |
Yes |
No |
HP-PRN-BW-A4-M401 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet 400 M401 | No |
No |
No |
Yes |
No |
HP-PRN-BW-A4-M401 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet P2055dn | No |
No |
No |
Yes |
No |
HP-BW-PRT-2055DN | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet P2016 Series | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet P2015 Series | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 9050 | No |
Yes |
No |
Yes |
No |
HP-BW-A3 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet 9040 | No |
No |
No |
Yes |
No |
HP-BW-A3 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet 8150 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 8000 Series | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 5100 Series | No |
Yes |
No |
Yes |
No |
HP-BW-PRT-A3 | No |
No |
Recommended driver:HP-BW-PRT-A3 Limitations:Duplex is identified from printed job, FALSEt from machine counters, i.e. accounting of duplex depends on operating system printing drivers. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 4350 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 4250 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 4200 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 4050 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 3392 | Yes |
No |
No |
Yes |
No |
HP-BW-A4-MFP-3392 | No |
No |
Recommended driver:HP-BW-A4-MFP-3392 Limitations:Counters for copy and print are shared. Driver is using separated duplex counters. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 3390 | Yes |
No |
No |
Yes |
No |
HP-BW-A4-MFP-3392 | No |
No |
Recommended driver:HP-BW-A4-MFP-3392 Limitations:Counters for copy and print are shared. Driver is using separated duplex counters. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 3380 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 3005dn | No |
No |
No |
Yes |
No |
HP-BW-A4-3005DN | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet 2430dtn | No |
No |
No |
Yes |
No |
HP-BW-A4-3005DN | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet 2300 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 2200 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet P4515 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet P1505n | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 4100 Series | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 4000 Series | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 1320N | No |
No |
No |
Yes |
No |
HP-BW-PRT-3 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | LaserJet 1320 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 1300N | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 1300 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 9500 | Yes |
No |
Yes |
Yes |
No |
HP-COL-A3-MFP | No |
No |
Recommended driver:HP-COL-A3-MFP Limitations:Counters for copy and print are shared. Driver is using separated duplex counters. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 5500 | No |
Yes |
Yes |
Yes |
No |
HP-COL-A3 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | Color LaserJet 5225DN | No |
Yes |
Yes |
Yes |
No |
HP-PRN-COL-A3-CP5225N | No |
No |
Recommended driver:HP-PRN-COL-A3-CP5225N Limitations:Each A3 page is accounted as A4 page. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 5225N | No |
Yes |
Yes |
Yes |
No |
HP-PRN-COL-A3-CP5225N | No |
No |
Recommended driver:HP-PRN-COL-A3-CP5225N Limitations:Each A3 page is accounted as A4 page. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 5225 | No |
Yes |
Yes |
Yes |
No |
HP-PRN-COL-A3-CP5225N | No |
No |
Recommended driver:HP-PRN-COL-A3-CP5225N Limitations:Each A3 page is accounted as A4 page. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 4700DN | No |
No |
Yes |
Yes |
No |
HP-COL-PRT | No |
No |
Recommended driver:HP-COL-PRT Limitations:Duplex print is accounted according to parser from job information.Driver may cause device locks in case of low toner. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 4700 | No |
No |
Yes |
Yes |
No |
HP-COL-PRT | No |
No |
Recommended driver:HP-COL-PRT Limitations:Duplex print is accounted according to parser from job information.Driver may cause device locks in case of low toner. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 4650 | No |
No |
Yes |
Yes |
No |
HP-COL-PRT | No |
No |
Recommended driver:HP-COL-PRT Limitations:Duplex print is accounted according to parser from job information.Driver may cause device locks in case of low toner. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 4600 | No |
No |
Yes |
Yes |
No |
HP-COL-PRT | No |
No |
Recommended driver:HP-COL-PRT Limitations:Duplex print is accounted according to parser from job information.Driver may cause device locks in case of low toner. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 4550 | No |
No |
Yes |
Yes |
No |
HP-COL-PRT | No |
No |
Recommended driver:HP-COL-PRT Limitations:Duplex print is accounted according to parser from job information.Driver may cause device locks in case of low toner. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 4500 | No |
No |
Yes |
Yes |
No |
HP-COL-PRT | No |
No |
Recommended driver:HP-COL-PRT Limitations:Duplex print is accounted according to parser from job information.Driver may cause device locks in case of low toner. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 3700 | No |
No |
Yes |
Yes |
No |
HP-COL-PRT | No |
No |
Recommended driver:HP-COL-PRT Limitations:Duplex print is accounted according to parser from job information.Driver may cause device locks in case of low toner. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 3550 | No |
No |
Yes |
Yes |
No |
HP-COL-PRT-3550 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | Color LaserJet 2840 mfp | Yes |
No |
Yes |
Yes |
No |
HP-COL-A4-MFP-2 | No |
No |
Recommended driver:HP-COL-A4-MFP-2 Limitations:Counters for copy and print are shared. Driver is using separated duplex counters. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 2840 | No |
No |
Yes |
Yes |
No |
HP-COL-PRT | No |
No |
Recommended driver:HP-COL-PRT Limitations:Duplex print is accounted according to parser from job information.Driver may cause device locks in case of low toner. | No |
Untested |
No |
No |
No |
No |
||
HP | Color InkJet CP1700 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | Color InkJet 3000 | No |
No |
Yes |
Yes |
No |
HP-COL-PRT | No |
No |
Recommended driver:HP-COL-PRT Limitations:Duplex print is accounted according to parser from job information.Driver may cause device locks in case of low toner. | No |
Untested |
No |
No |
No |
No |
||
HP | Business InkJet 2800 | No |
Yes |
No |
Yes |
No |
HP-BW-PRT-A3 | No |
No |
Recommended driver:HP-BW-PRT-A3 Limitations:Duplex is identified from printed job, FALSEt from machine counters, i.e. accounting of duplex depends on operating system printing drivers. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet M4555F mfp | Yes |
No |
No |
Yes |
Yes |
HP-BW-A4-MFP-4555 | No |
No |
Recommended driver:HP-BW-A4-MFP-4555 Limitations:Duplex pages are accounted as simplex. Odd number of pages printed/copied in duplex is accounted with one more page (e.g. 3 pages printed in duplex are accounted as 4 printed pages). Counters for copy and print are shared. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
Because the MFP does not have the free holes for mounting of an external terminal available, we recommend to use an universal table mounting kit.
|
|
HP | LaserJet M4555 mfp | Yes |
No |
No |
Yes |
Yes |
HP-BW-A4-MFP-4555 | No |
No |
Recommended driver:HP-BW-A4-MFP-4555 Limitations:Duplex pages are accounted as simplex. Odd number of pages printed/copied in duplex is accounted with one more page (e.g. 3 pages printed in duplex are accounted as 4 printed pages). Counters for copy and print are shared. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
Because the MFP does not have the free holes for mounting of an external terminal available, we recommend to use an universal table mounting kit.
|
|
HP | LaserJet M5035 mfp | Yes |
No |
No |
Yes |
Yes |
HP-BW-A3-MFP | No |
No |
Recommended driver:HP-BW-A3-MFP Limitations:Counters for copy and print are shared. Driver is using separated duplex counters. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
Because the MFP does not have the free holes for mounting of an external terminal available, we recommend to use an universal table mounting kit.
|
|
HP | LaserJet M3035 mfp | Yes |
No |
No |
Yes |
Yes |
HP-BW-A4-MFP | No |
No |
Recommended driver:HP-BW-A4-MFP Limitations:Counters for copy and print are shared. Driver is using separated duplex counters. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
Because the MFP does not have the free holes for mounting of an external terminal available, we recommend to use an universal table mounting kit.
|
|
HP | LaserJet M3027 mfp | Yes |
No |
No |
Yes |
Yes |
HP-BW-A4-MFP | No |
No |
Recommended driver:HP-BW-A4-MFP Limitations:Counters for copy and print are shared. Driver is using separated duplex counters. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | CM2320n | Yes |
No |
Yes |
Yes |
No |
HP-COL-MFP-CM2320fxi | No |
No |
Recommended driver:HP-COL-MFP-CM2320fxi Limitations:Driver accounts A4 black-and-white duplex print job as A4 black-and-white simplex print job. Driver accounts A4 color simplex print job as A4 black-and-white simplex print job. Driver accounts A4 color duplex print job as A4 black-and-white simplex print job. Driver accounts A4 black-and-white duplex copy job as A4 black-and-white simplex copy job. Driver accounts A4 color simplex copy job as A4 black-and-white simplex copy job. Driver accounts A4 color duplex copy job as A4 black-and-white simplex copy job. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
HP | CM2320nf | Yes |
No |
Yes |
Yes |
No |
HP-COL-MFP-CM2320fxi | No |
No |
Recommended driver:HP-COL-MFP-CM2320fxi Limitations:Driver accounts A4 black-and-white duplex print job as A4 black-and-white simplex print job. Driver accounts A4 color simplex print job as A4 black-and-white simplex print job. Driver accounts A4 color duplex print job as A4 black-and-white simplex print job. Driver accounts A4 black-and-white duplex copy job as A4 black-and-white simplex copy job. Driver accounts A4 color simplex copy job as A4 black-and-white simplex copy job. Driver accounts A4 color duplex copy job as A4 black-and-white simplex copy job. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
HP | CM2320fxi | Yes |
No |
Yes |
Yes |
No |
HP-COL-MFP-CM2320fxi | No |
No |
Recommended driver:HP-COL-MFP-CM2320fxi Limitations:Driver accounts A4 black-and-white duplex print job as A4 black-and-white simplex print job. Driver accounts A4 color simplex print job as A4 black-and-white simplex print job. Driver accounts A4 color duplex print job as A4 black-and-white simplex print job. Driver accounts A4 black-and-white duplex copy job as A4 black-and-white simplex copy job. Driver accounts A4 color simplex copy job as A4 black-and-white simplex copy job. Driver accounts A4 color duplex copy job as A4 black-and-white simplex copy job. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 9050 mfp | Yes |
Yes |
No |
Yes |
Yes |
HP-BW-A3-MFP | No |
No |
Recommended driver:HP-BW-A3-MFP Limitations:Counters for copy and print are shared. Driver is using separated duplex counters. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
Because the MFP does not have the free holes for mounting of an external terminal available, we recommend to use an universal table mounting kit.
|
|
HP | LaserJet 9040 mfp | Yes |
Yes |
No |
Yes |
Yes |
HP-BW-A3-MFP | No |
No |
Recommended driver:HP-BW-A3-MFP Limitations:Counters for copy and print are shared. Driver is using separated duplex counters. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
Because the MFP does not have the free holes for mounting of an external terminal available, we recommend to use an universal table mounting kit.
|
|
HP | LaserJet 9000 mfp | Yes |
Yes |
No |
Yes |
Yes |
HP-BW-A3-MFP | No |
No |
Recommended driver:HP-BW-A3-MFP Limitations:Counters for copy and print are shared. Driver is using separated duplex counters. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 5000 Series | No |
Yes |
No |
Yes |
No |
HP-BW-PRT-A3 | No |
No |
Recommended driver:HP-BW-PRT-A3 Limitations:Duplex is identified from printed job, FALSEt from machine counters, i.e. accounting of duplex depends on operating system printing drivers. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet M4345 | Yes |
No |
No |
Yes |
No |
HP-MFP-BW-A4-M4345 | No |
No |
Recommended driver:HP-MFP-BW-A4-M4345 Limitations:Counters for copy and print are shared.Supported firmware is 20130510 or newer.There is a 3 seconds timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet 4345 mfp | Yes |
No |
No |
Yes |
Yes |
HP-BW-A4-MFP | No |
No |
Recommended driver:HP-BW-A4-MFP Limitations:Counters for copy and print are shared. Driver is using separated duplex counters. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet CP4520 | No |
No |
Yes |
Yes |
No |
HP-COL-DUP-CP4525 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | Color LaserJet CP4525 | No |
No |
Yes |
Yes |
No |
HP-COL-DUP-CP4525 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
HP | Color LaserJet CP3525 | No |
No |
Yes |
Yes |
No |
HP-COL-PRT | No |
No |
Recommended driver:HP-COL-PRT Limitations:Duplex print is accounted according to parser from job information.Driver may cause device locks in case of low toner. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet 9500 mfp | Yes |
Yes |
Yes |
Yes |
Yes |
HP-COL-A3-MFP | No |
No |
Recommended driver:HP-COL-A3-MFP Limitations:Counters for copy and print are shared. Driver is using separated duplex counters. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet CM6040 | Yes |
Yes |
Yes |
Yes |
Yes |
HP-COL-A3-MFP-6040-DUP | No |
No |
Recommended driver:HP-COL-A3-MFP-6040-DUP Limitations:Only pages printed before the device goes completely out of paper (FALSE paper in all trays) are accounted.Counters for copy and print are shared. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
Foreign interface harness (FIH) is required for external terminal. Because the MFP does not have the free holes for mounting of an external terminal available. We recommend to use an universal table mounting kit.
|
|
HP | Color LaserJet CM6030 | Yes |
Yes |
Yes |
Yes |
Yes |
HP-COL-A3-MFP-6040-DUP | No |
No |
Recommended driver:HP-COL-A3-MFP-6040-DUP Limitations:Only pages printed before the device goes completely out of paper (FALSE paper in all trays) are accounted.Counters for copy and print are shared. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
Foreign interface harness (FIH) is required for external terminal. Because the MFP does not have the free holes for mounting of an external terminal available. We recommend to use an universal table mounting kit.
|
|
HP | Color LaserJet 4730 mfp | Yes |
No |
Yes |
Yes |
Yes |
HP-COL-A4-MFP | No |
No |
Recommended driver:HP-COL-A4-MFP Limitations:Counters for copy and print are shared. Driver is using separated duplex counters. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet CP2025dn | No |
No |
Yes |
Yes |
No |
HP-COL-PRT | No |
No |
Recommended driver:HP-COL-PRT Limitations:Duplex print is accounted according to parser from job information.Driver may cause device locks in case of low toner. | No |
Untested |
No |
No |
No |
No |
||
HP | Color LaserJet Enterprise MFP58045 | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
HP | LaserJet E73140 | GEMSTONE 2.0 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Yes |
No |
No |
No |
No |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
- Also known as HP Color LaserJet Managed MFP E731dn
- Also fits for Flow version Color LaserJet Flow E73140 or Color LaserJet Managed Flow MFP E731z
|
||
HP | E826z | LaserJet Managed Flow MFP | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
|
||
HP | LaserJet Managed MFP E826dn | GEMSTONE 2.0 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Yes |
No |
No |
No |
No |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
- Also fits for Color LaserJet Managed Flow MFP E826z
|
||
HP | E786z | Color LaserJet Managed Flow MFP | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
|
||
HP | Color LaserJet Managed Flow MFP E877 | GEMSTONE 2.0 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
No |
Yes |
|||
HP | E87770 | Color LaserJet Managed Flow MFP | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
|
||
HP | E78228dn | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and MU20 required EAP license
FW bundle version 4.6.0.1 and later required for USB readers
|
|||
HP | LaserJet Enterprise MFP M480f | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
IPP Accounting available with limitation LIMIT-177. |
|||
HP | LaserJet MFP E47528 | Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
IPP Accounting available with limitation LIMIT-177. |
|||
HP | HP LaserJet Enterprise MFP M430, M431 | LaserJet Enterprise | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
IPP Accounting available with limitation (LIMIT-177). |
||
HP | LaserJet MFP E42540 | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
IPP Accounting available with limitation LIMIT-177. |
|||
HP | M507dn | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
Device does not have touch display - Embedded terminal is not supported.
|
|||
HP | M507x | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
HP | E62665 | LaserJet Flow MFP | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
No |
Untested |
No |
No |
No |
Yes |
|||
HP | LaserJet Managed MFP E62655 | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
||||
HP | M776 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
||||
HP | P77960 | PageWide | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Firmware bundle 4.8.1 and later required.
|
||
HP | P77950 | PageWide | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Firmware bundle 4.8.1 and later required.
|
||
HP | P77940 | PageWide | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Firmware bundle 4.8.1 and later required.
|
||
HP | LaserJet Managed E50045 | No |
No |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
||||
HP | PageWide P57750 | PageWide Pro | Yes |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
Does not support Embedded technology for SafeQ Embedded terminal.
|
||
HP | LaserJet Pro M426 | LaserJet Pro | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
Does not support Embedded technology for SafeQ Embedded terminal.
|
||
HP | PageWide P77760 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
Does not support Embedded technology for SafeQ Embedded terminal.
|
|||
HP | PageWide P77750 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
Does not support Embedded technology for SafeQ Embedded terminal.
|
|||
HP | PageWide P77740 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
Does not support Embedded technology for SafeQ Embedded terminal.
|
|||
HP | LaserJet E72535 | E725xx | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and MU20 required EAP license
FW bundle version 4.6.0.1 and later required for USB readers
|
||
HP | LaserJet Managed MFP E72530 | E725xx | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and MU20 required EAP license
FW bundle version 4.6.0.1 and later required for USB readers
|
||
HP | LaserJet E72525 | E725xx | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and MU20 required EAP license
FW bundle version 4.6.0.1 and later required for USB readers
|
||
HP | LaserJet Managed E82560 | E825xx series | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
Yes |
No |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and MU20 required EAP license
FW bundle version 4.6.0.1 and later required for USB readers
|
||
HP | LaserJet Managed E82540 | E825xx series | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
Yes |
No |
FW bundle version 4.6.0.1 and later required for USB readers
YSoft SafeQ 5 MU39 and later recommended
|
||
HP | LaserJet Managed E82550 | E825xx series | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
Yes |
No |
FW bundle version 4.6.0.1 and later required for USB readers
YSoft SafeQ 5 MU39 and later recommended
|
||
HP | Color LaserJet Managed MFP E87660 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
* YSoft SafeQ 5 MU39 and later recommended
* YSoft SafeQ 6 MU19 and MU20 require EAP license.
* FW bundle version 4.6.0.1 and later required for USB readers
|
|||
HP | Color LaserJet Managed MFP E87650 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
* YSoft SafeQ 5 MU39 and later recommended
* YSoft SafeQ 6 MU19 and MU20 require EAP license.
* FW bundle version 4.6.0.1 and later required for USB readers
|
|||
HP | Color LaserJet Managed MFP E87640 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
* YSoft SafeQ 5 MU39 and later recommended
* YSoft SafeQ 6 MU19 and MU20 require EAP license.
* FW bundle version 4.6.0.1 and later required for USB readers
|
|||
HP | Color LaserJet E78528 | GEMSTONE 2.0 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
HP | E78523 | Color LaserJet Managed MFP | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
HP | E731z | LaserJet Managed Flow MFP | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
|
||
HP | E731dn | LaserJet Managed MFP | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
- Also fits for Color LaserJet Managed Flow MFP E731z
|
||
HP | E73135 | LaserJet Managed Flow MFP | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
- Also known as HP Color LaserJet Managed MFP E731dn
- Also fits for Flow version Color LaserJet Flow E73135 or Color LaserJet Managed Flow MFP E731z
|
||
HP | E73130 | LaserJet Managed Flow MFP | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
- Also known as HP Color LaserJet Managed MFP E731dn
- Also fits for Flow version Color LaserJet Flow E73130 or Color LaserJet Managed Flow MFP E731z
|
||
HP | E82670 | LaserJet Managed Flow MFP | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
- Also known as HP Color LaserJet Managed MFP E826dn
- Also fits for Flow version Color LaserJet Flow E82670 or Color LaserJet Managed Flow MFP E826z
|
||
HP | E82660 | LaserJet Managed Flow MFP | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
- Also known as HP Color LaserJet Managed MFP E826dn
- Also fits for Flow version Color LaserJet Flow E82660 or Color LaserJet Managed Flow MFP E826z
|
||
HP | E82650 | LaserJet Managed Flow MFP | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
- Also known as HP Color LaserJet Managed MFP E826dn
- Also fits for Flow version Color LaserJet Flow E82650 or Color LaserJet Managed Flow MFP E826z
|
||
HP | E786dn | Color LaserJet Managed MFP | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
- Also fits for Flow version Color LaserJet Managed Flow MFP E786z
|
||
HP | E78635 | Color LaserJet Managed Flow MFP | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
- Also known as HP Color LaserJet Managed MFP E786dn
- Also fits for Flow version Color LaserJet Flow E878635 or Color LaserJet Managed Flow MFP E786z
|
||
HP | E78630 | Color LaserJet Managed MFP | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
- Not tested - Embedded terminal should works based on used technology - GEM 2.0 devices.
- Also known as HP Color LaserJet Managed MFP E786dn
- Also fits for Flow version Color LaserJet Flow E878630 or Color LaserJet Managed Flow MFP E786z
|
||
HP | E877dn | Color LaserJet Managed MFP | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
No |
Yes |
Also fits for Flow HP Color LaserJet Managed Flow MFP E877z |
||
HP | E87760 | Color LaserJet Managed Flow MFP | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
|
||
HP | E87750 | Color LaserJet Managed Flow MFP | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
|
||
HP | E87740 | Color LaserJet Managed Flow MFP | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
|
||
HP | M578 | Color LaserJet MFP | Yes |
No |
Yes |
Yes |
Yes |
HP-MFP-COL-A4-M475 | Yes |
Yes |
Recommended driver: HP-MFP-COL-A4-M475 Limitations: Counters for copy and print are shared. When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled. There is a 5 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
HP | M682 | Color LaserJet FlowMFP | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
No |
Untested |
No |
No |
No |
Yes |
|||
HP | M681 | Color LaserJet FlowMFP | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
No |
Untested |
No |
No |
No |
Yes |
|||
HP | PageWide Enterprise Color 556 | No |
No |
Yes |
Yes |
No |
HP-PRN-COL-A4-556DN | No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
|||
HP | Color LaserJet Managed Flow E57540c | Yes |
No |
Yes |
Yes |
Yes |
HP-MFP-COL-A4-M475 | Yes |
Yes |
Recommended driver: HP-MFP-COL-A4-M475 Limitations: Counters for copy and print are shared. When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled. There is a 5 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
|
HP | Color LaserJet Managed E57540dn | Yes |
No |
Yes |
Yes |
Yes |
HP-MFP-COL-A4-M475 | No |
No |
Recommended driver: HP-MFP-COL-A4-M475 Limitations: Counters for copy and print are shared. When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled. There is a 5 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
|
HP | LaserJet E60075x | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver: HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | Yes |
Yes |
No |
No |
No |
Yes |
Printer only, Scan application not supported.
Firmware bundle 4.6.0.1 and later required for USB reader support.
4.3 inch display required.
|
|
HP | LaserJet E60065x | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver: HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | Yes |
Yes |
No |
No |
No |
Yes |
Printer only, Scan application not supported.
Firmware bundle 4.6.0.1 and later required for USB reader support.
4.3 inch display required.
|
|
HP | LaserJet M609x | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver: HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | Yes |
Yes |
No |
No |
No |
Yes |
Printer only, Scan application not supported.
Firmware bundle 4.6.0.1 and later required for USB reader support.
4.3 inch display required.
|
|
HP | PageWide Managed Color MFP E58650 | PageWide | Yes |
No |
Yes |
Yes |
No |
HP-MFP-COL-A4-586 | No |
No |
Recommended driver: HP-MFP-COL-A4-586 Limitations: Counters for copy and print are shared. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader supported with firmware version bundle 4.6.0.1 and later.
|
HP | LaserJet MFP M633 | LaserJet | Yes |
No |
No |
Yes |
No |
HP-MFP-BW-A4-M630 | No |
No |
Recommended driver: HP-MFP-BW-A4-M630 Limitations: Counters for copy and print are shared. All counters start with 1. | Yes |
Yes |
No |
No |
No |
Yes |
* YSoft SafeQ 5 MU39 and later recommended
* YSoft SafeQ 6 MU19 and MU20 require EAP license.
* FW bundle version 4.6.0.1 and later required for USB readers
|
HP | LaserJet MFP E62575 | LaserJet | Yes |
No |
Yes |
Yes |
Yes |
HP-MFP-BW-A4-M527 | Yes |
Yes |
Recommended driver: HP-MFP-BW-A4-M527 Limitations: There is a 1 seconds timeout after print. Counters for copy and print are shared. Scan counter start with 1. If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | Yes |
Yes |
No |
No |
No |
Yes |
* YSoft SafeQ 5 MU39 and later recommended
* YSoft SafeQ 6 MU19 and MU20 require EAP license.
* FW bundle version 4.6.0.1 and later required for USB readers
|
HP | LaserJet MFP E62565 | LaserJet | Yes |
No |
No |
Yes |
Yes |
HP-MFP-BW-A4-M527 | Yes |
Yes |
Recommended driver: HP-MFP-BW-A4-M527 Limitations: There is a 1 seconds timeout after print. Counters for copy and print are shared. Scan counter start with 1. If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | Yes |
Yes |
No |
No |
No |
Yes |
* YSoft SafeQ 5 MU39 and later recommended
* YSoft SafeQ 6 MU19 and MU20 require EAP license.
* FW bundle version 4.6.0.1 and later required for USB readers
|
HP | HP LaserJet E60075 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver: HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet E60065 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver: HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Yes |
No |
No |
No |
No |
||
HP | HP LaserJet E60055 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver: HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. IPP Accounting Limitation: Blank pages are also accounted (when duplex job) | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet Enterprise M607/M608/M609 | LaserJet Enterprise | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
Yes |
Recommended driver: HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | Yes |
Yes |
No |
No |
No |
Yes |
|
HP | HP LaserJet M609 | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver: HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
HP | LaserJet MFP E62555 | LaserJet | Yes |
No |
No |
Yes |
Yes |
HP-MFP-BW-A4-M527 | No |
No |
Recommended driver: HP-MFP-BW-A4-M527 Limitations: There is a 1 seconds timeout after print. Counters for copy and print are shared. Scan counter start with 1. If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | Yes |
Yes |
No |
No |
No |
Yes |
* YSoft SafeQ 5 MU39 and later recommended
* YSoft SafeQ 6 MU19 and MU20 require EAP license.
* FW bundle version 4.6.0.1 and later required for USB readers
IPP Accounting available with limitation LIMIT-177
|
HP | PageWide Managed Color E77660 | E776xx series | Yes |
Yes |
Yes |
Yes |
No |
HP-MFP-COL-A3-M880 | No |
No |
Recommended driver: HP-MFP-COL-A3-M880 Limitation: Counters for copy and print are shared. All counters start with 1. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
FW bundle version 4.6.0.1 and later required for USB readers
YSoft SafeQ 5 MU39 and later recommended
|
HP | PageWide Managed Color E77650 | E776xx series | Yes |
Yes |
Yes |
Yes |
No |
HP-MFP-COL-A3-M880 | No |
No |
Recommended driver: HP-MFP-COL-A3-M880 Limitation: Counters for copy and print are shared. All counters start with 1. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
FW bundle version 4.6.0.1 and later required for USB readers
YSoft SafeQ 5 MU39 and later recommended
|
HP | Color LaserJet Managed MFP E77830 | Yes |
Yes |
Yes |
Yes |
No |
HP-MFP-COL-A3-M880 | No |
No |
Recommended driver: HP-MFP-COL-A3-M880 Limitation: Counters for copy and print are shared. All counters start with 1. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
* YSoft SafeQ 5 MU39 and later recommended
* YSoft SafeQ 6 MU19 and MU20 require EAP license.
* FW bundle version 4.6.0.1 and later required for USB readers
|
|
HP | Color LaserJet Managed MFP E77825 | Yes |
Yes |
Yes |
Yes |
No |
HP-MFP-COL-A3-M880 | No |
No |
Recommended driver: HP-MFP-COL-A3-M880 Limitation: Counters for copy and print are shared. All counters start with 1. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
* YSoft SafeQ 5 MU39 and later recommended
* YSoft SafeQ 6 MU19 and MU20 require EAP license.
* FW bundle version 4.6.0.1 and later required for USB readers
|
|
HP | Color LaserJet Managed MFP E77822 | Yes |
Yes |
Yes |
Yes |
No |
HP-MFP-COL-A3-M880 | No |
No |
Recommended driver: HP-MFP-COL-A3-M880 Limitation: Counters for copy and print are shared. All counters start with 1. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
* YSoft SafeQ 5 MU39 and later recommended
* YSoft SafeQ 6 MU19 and MU20 require EAP license.
* FW bundle version 4.6.0.1 and later required for USB readers
|
|
HP | LaserJet MFP M631 | LaserJet | Yes |
No |
No |
Yes |
No |
HP-MFP-BW-A4-M630 | No |
No |
Recommended driver: HP-MFP-BW-A4-M630 Limitations: Counters for copy and print are shared. All counters start with 1. | Yes |
Yes |
No |
No |
No |
Yes |
* YSoft SafeQ 5 MU39 and later recommended
* YSoft SafeQ 6 MU19 and MU20 require EAP license.
* FW bundle version 4.6.0.1 and later required for USB readers
|
HP | LaserJet MFP M632 | LaserJet | Yes |
No |
No |
Yes |
No |
HP-MFP-BW-A4-M630 | No |
No |
Recommended driver: HP-MFP-BW-A4-M630 Limitations: Counters for copy and print are shared. All counters start with 1. | Yes |
Yes |
No |
No |
No |
Yes |
* YSoft SafeQ 5 MU39 and later recommended
* YSoft SafeQ 6 MU19 and MU20 require EAP license.
* FW bundle version 4.6.0.1 and later required for USB readers
|
HP | LaserJet Pro MFP M477 | LaserJet | Yes |
No |
Yes |
Yes |
No |
HP-MFP-COL-A4-M475 | No |
No |
Limitations: Counters for copy and print are shared. When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled. There is a 5 seconds timeout after copy. Device canFALSEt be blocked. | No |
Untested |
No |
No |
No |
No |
|
HP | LaserJet 400 M402dw | LaserJet | No |
No |
No |
Yes |
No |
HP-PRN-BW-A4-DUP-M402 | No |
No |
Recommended driver:HP-PRN-BW-A4-DUP-M402 Limitations:If device runs out of paper during print/copy, jobs are accounted after the paper is refilled.Device is FALSEt ready when its out of paper | No |
Untested |
No |
No |
No |
No |
|
HP | LaserJet 400 M402dn | LaserJet | No |
No |
No |
Yes |
No |
HP-PRN-BW-A4-DUP-M402 | No |
No |
Recommended driver:HP-PRN-BW-A4-DUP-M402 Limitations:If device runs out of paper during print/copy, jobs are accounted after the paper is refilled.Device is FALSEt ready when its out of paper | No |
Untested |
No |
No |
No |
No |
|
HP | Laserjet Managed M506xm | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | Laserjet Managed M506dnm | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | LasetJet Enterprise M506xm | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | LasetJet Enterprise M506dnm | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | LasetJet Enterprise M506x | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | LasetJet Enterprise M506dn | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | LasetJet Enterprise M506n | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | LaserJet Managed M605xm | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | LaserJet Managed M605dnm | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | LasetJet Enterprise M605xm | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | LasetJet Enterprise M605dnm | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | LasetJet Enterprise M606dn | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | LasetJet Enterprise M605dn | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | LasetJet Enterprise M604dn | LaserJet | No |
No |
No |
Yes |
No |
HP-BW-PRT | No |
No |
Recommended driver:HP-BW-PRT Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
HP | M577z | Color LaserJet FlowMFP | Yes |
No |
Yes |
Yes |
Yes |
HP-MFP-COL-A4-M475 | Yes |
Yes |
Recommended driver: HP-MFP-COL-A4-M475 Limitations: Counters for copy and print are shared. When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled. There is a 5 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
HP | M577c | Color LaserJet FlowMFP | Yes |
No |
Yes |
Yes |
Yes |
HP-MFP-COL-A4-M475 | Yes |
Yes |
Recommended driver: HP-MFP-COL-A4-M475 Limitations: Counters for copy and print are shared. When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled. There is a 5 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
HP | LasetJet Enterprise MFP M577f | LaserJet | Yes |
No |
Yes |
Yes |
Yes |
HP-MFP-COL-A4-M475 | Yes |
Yes |
Recommended driver: HP-MFP-COL-A4-M475 Limitations: Counters for copy and print are shared. When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled. There is a 5 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
HP | LasetJet Enterprise MFP M577dn | LaserJet | Yes |
No |
Yes |
Yes |
Yes |
HP-MFP-COL-A4-M475 | Yes |
Yes |
Recommended driver: HP-MFP-COL-A4-M475 Limitations: Counters for copy and print are shared. When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled. There is a 5 seconds timeout after copy. Blocking interface limitations: Only copy function can be blocked via FIH port. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
HP | LaserJet Enterprise M527cm | LaserJet | Yes |
No |
No |
Yes |
Yes |
HP-MFP-BW-A4-M527 | No |
No |
Recommended driver: HP-MFP-BW-A4-M527 Limitations: There is a 1 seconds timeout after print. Counters for copy and print are shared. Scan counter start with 1. If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
HP | LaserJet Enterprise M527dnm | LaserJet | Yes |
No |
No |
Yes |
Yes |
HP-MFP-BW-A4-M527 | No |
No |
Recommended driver: HP-MFP-BW-A4-M527 Limitations: There is a 1 seconds timeout after print. Counters for copy and print are shared. Scan counter start with 1. If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
HP | M527c | LaserJet Enterprise Flow | Yes |
No |
No |
Yes |
Yes |
HP-MFP-BW-A4-M527 | Yes |
Yes |
Recommended driver: HP-MFP-BW-A4-M527 Limitations: There is a 1 seconds timeout after print. Counters for copy and print are shared. Scan counter start with 1. If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
HP | M527z | LaserJet Enterprise Flow | Yes |
No |
No |
Yes |
Yes |
HP-MFP-BW-A4-M527 | Yes |
Yes |
Recommended driver: HP-MFP-BW-A4-M527 Limitations: There is a 1 seconds timeout after print. Counters for copy and print are shared. Scan counter start with 1. If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
HP | M527f | LaserJet Enterprise MFP | Yes |
No |
Yes |
Yes |
Yes |
HP-MFP-BW-A4-M527 | Yes |
Yes |
Recommended driver: HP-MFP-BW-A4-M527 Limitations: There is a 1 seconds timeout after print. Counters for copy and print are shared. Scan counter start with 1. If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
HP | M527dn | LaserJet Enterprise MFP | Yes |
No |
Yes |
Yes |
Yes |
HP-MFP-BW-A4-M527 | Yes |
Yes |
Recommended driver: HP-MFP-BW-A4-M527 Limitations: There is a 1 seconds timeout after print. Counters for copy and print are shared. Scan counter start with 1. If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
HP | LaserJet Managed M527cm | LaserJet | Yes |
No |
No |
Yes |
Yes |
HP-MFP-BW-A4-M527 | No |
No |
Recommended driver: HP-MFP-BW-A4-M527 Limitations: There is a 1 seconds timeout after print. Counters for copy and print are shared. Scan counter start with 1. If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
HP | LaserJet Managed M527dnm | LaserJet | Yes |
No |
No |
Yes |
Yes |
HP-MFP-BW-A4-M527 | No |
No |
Recommended driver: HP-MFP-BW-A4-M527 Limitations: There is a 1 seconds timeout after print. Counters for copy and print are shared. Scan counter start with 1. If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | Yes |
Yes |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU39 and later recommended
YSoft SafeQ 6 MU19 and later recommended
USB reader currently supported with firmware bundle 4.6.0.1 and later
|
HP | LaserJet Pro 500 M570dn | LaserJet | Yes |
No |
Yes |
Yes |
No |
HP-MFP-COL-A4-M570 | No |
No |
Recommended driver:HP-MFP-COL-A4-M570 Limitations:Counters for copy and print are shared.All counter start with 1 | No |
Untested |
No |
No |
No |
No |
|
HP | Color LaserJet MFP M476dw | LaserJet | Yes |
No |
Yes |
Yes |
No |
HP-MFP-COL-A4-M475 | No |
No |
Recommended driver:HP-MFP-COL-A4-M475 Limitations:Counters for copy and print are shared.When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled.There is a 5 seconds timeout after copy. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
|
HP | Color LaserJet MFP M476dn | LaserJet | Yes |
No |
Yes |
Yes |
No |
HP-MFP-COL-A4-M475 | No |
No |
Recommended driver:HP-MFP-COL-A4-M475 Limitations:Counters for copy and print are shared.When the device runs out of paper during print/copy, jobs are accounted after the paper is refilled.There is a 5 seconds timeout after copy. Blocking interface limitations:Only copy function can be blocked via FIH port. | No |
Untested |
No |
No |
No |
No |
|
HP | Color LaserJet Enterprise X55745dn | No |
No |
Yes |
Yes |
No |
Yes |
Yes |
No |
Untested |
No |
Yes |
No |
No |
||||
HP | LaserJet Enterprise MFP M430f/M431f | LaserJet Enterprise | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
HP | HP LaserJet Enterprise M610, M611, M612 | LaserJet Enterprise | No |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Untested |
No |
No |
No |
Yes |
|||
HP | HP Color LaserJet Enterprise MFP M776 Series | Color LaserJet Enterprise | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
HP | Color LaserJet Managed MFP E786 | Color LaserJet Managed | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
IBM | Color 1534 | Infoprint | No |
No |
Yes |
Yes |
No |
IBM-PRN-COL-A4 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
IBM | 1552 | Infoprint | No |
No |
No |
Yes |
No |
IBM-PRN-BW-A4 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
IBM | 1540 MFP | Infoprint | Yes |
Yes |
Yes |
Yes |
No |
IBM-MFP-BW-A3 | No |
No |
Recommended driver:IBM-MFP-BW-A3 Limitations:Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
|
Infotec | 1024 | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2245 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2235 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2230 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2225 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 270 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2238C | Yes |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2232C | Yes |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 228C | Yes |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2220 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2105 EB-105EX | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2105 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2090 EB-105EX | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2090 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2175 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2160 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2151 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2045e | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2045 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2035e | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2035 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2032 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2027 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2022 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2020D | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2020 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2018D | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2018 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2016 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 2015 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1515 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1232C | Yes |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1224C | Yes |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1075 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1060 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1045 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1035 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1032 | No |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1027 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1022 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1018D | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1018 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1015 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1013F | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | 1013 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Infotec | MP C7500 Series | Aficio MP C6000/C7500 Series | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Infotec | MP C6000 Series | Aficio MP C6000/C7500 Series | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Infotec | MP 3350 Series | Aficio MP 2550/3350 Series | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Infotec | MP 2550 Series | Russian-C5c | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Infotec | MP 5000 Series | Alex C1c | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Infotec | MP 4000 Series | Alex C1b | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Infotec | IS 2445 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Konica Minolta | AccurioPrint 2100 | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
Simplex PostScrips jobs are detected as duplex.
|
|||
Konica Minolta | C4080 | AccurioPrint, AccurioPress, Woodrose | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Untested |
No |
No |
No |
Yes |
|
||
Konica Minolta | C4070 | AccurioPrint, AccurioPress | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Untested |
No |
No |
No |
Yes |
|
||
Konica Minolta | C4065 | AccurioPrint, AccurioPress | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
Yes |
|
||
Konica Minolta | AccurioPrint C750i | AccurioPrint | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
Embedded terminal with EFI controller is not supported.
|
||
Konica Minolta | Workplace Hub | Workplace Hub | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
Yes |
Yes |
Tested Workplace Hub FW version Workplace Hub Firmware version: 1.9 Workplace Hub general limitation AuthenticationCache is not supported KioskMode is not supported MyPanel is not supported: Shortcut configuration by SafeQ is not supported. TLS1.1/TLS1.2 only are supported Logout by card is not supported Change to the panel (e.g Enabling/Disabling Workplace Hub internal PublicUser, Uninstall/Reinstall auth application) may not propagate the change to the panel display immediately until the display is refreshed. A Workplace Hub user can have 1 card only: SafeQ user can have multiple card, but because Workplace Hub can have only 1 card. If a different card shall be registered, existing card shall be removed from a user in Workplace Hub. For 1st time login by PIN, Username/Password, a user shall link them with Workplace Hub internal user by entering user name and password. If Embedded Terminal is reinstalled, this needs to be done again. For 1st time login by card, a user shall link them with Workplace Hub internal user by entering user name and password. Workplace Hub SW Keybord does not support Japanese. Authentication (SafeQ6 GEN2) Pressing key board “return key” does not action login for the authentication method “Username/Password”. (GEN2 Terminal defect - fix TBA) (SafeQ5 Native/GEN1, SafeQ6 Native) Pressing key board “return key” does not action login for the authentication method “PIN”, “Username/Password”. (To be confirmed as specification by Konica MInolta) To logout from Workplace Hub, a user shall navigate back to the Workplace Hub home menu and tap “logout”. Unlike bizhub model, there is no hardware logout button. (SafeQ5 Native/SafeQ6 Native) SafeQ user defined timeout is not supported. Use system auto reset timer of the MFD instead. (SafeQ5 GEN1/SafeQ6 GEN2) SafeQ user defined timeout only terminates SafeQ print/scan applications. Interface Unlike bizhub, user cannot change user language before login. User can change own language after login. MFD default language can only be changed by Workplace Hub administrator. (SafeQ5 Native/GEN1, SafeQ6 Native) Unlike bizhub models, user cannot change SafeQ application(authentication, print, scan interface) language before login. Also changing SafeQ application interface language is not supported by FW v1.9(Improvement is planned for FW v2.0) Print (SafeQ6 GEN2) Print All does not work if any Workplace Hub is integrated with the AD and any user is not assigned with e-mail address. (Improvement by Konica Minolta TBD) Scan (SafeQ5 GEN1/SafeQ6 GEN2) Attempting to scan to “JPEG in BW” using SafeQ Scan Workflow does not start scanning because it is unsupported combination by Workplace Hub Payment System Payment System integration is not certified yet for Workplace Hub because of the first limitation bellow. Workplace Hub tries to authenticate the print job 2 times due to which the print is deleted as error if a job owner’s balance is less than double of the print job’s price. (Improvement is planned for FW v2.0) If the user presses “logout” on consuming all the balance and logout from Workplace Hub, “Access Denied. Insufficient permissions. Please Contact your Workplace Hub Admin” message is displayed if Workplace Hub internal Public User is not enabled (Improvement in later FW version TBD) Other (Improvement in later FW version TBD) If the user attempts to run SafeQ print/scan application while they are still running, application loading spinner is displayed for a long time. This may happen in following situations: The user pressed "home" button and attempts to enter SafeQ print application while printing is ongoing. The user pressed "home" button and attempts to enter SafeQ scan application while scanning is ongoing. The user pressed "home" button and quickly attempts to enter SafeQ print/scan application while they are still up.
|
||
Konica Minolta | 6120 | AccurioPress | Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | 6136 | AccurioPress | Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | AccurioPrint C759 | AccurioPrint | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
Not possible to integrate with Embedded terminal.
|
||
Konica Minolta | PRO C6500 | bizhub | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | PRO C5501 | bizhub | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | PRO C5500 | bizhub | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | 950i | bizhub | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | 850i | bizhub | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | 751i | bizhub | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | 651i | bizhub | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | 551i | bizhub | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | 451i | bizhub | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | 301i | bizhub | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | C751i | bizhub | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | C651i | bizhub | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | C551i | bizhub | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | C451i | bizhub | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | C361i | bizhub | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | C301i | bizhub | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | C251i | bizhub | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | 4751i | bizhub | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | 4701i | bizhub | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
LD device since SAFEQ 6 Build 99. |
||
Konica Minolta | 4051i | bizhub | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
LD Device since SAFEQ 6 Build 97
|
||
Konica Minolta | C4051i | bizhub | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | C3301i | bizhub | No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
LD Device since SAFEQ 6 Build 99. |
||
Konica Minolta | C3321i | bizhub | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
LD Device since SAFEQ 6 Build 95.
|
||
Konica Minolta | 450i | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 / MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested ROM version SafeQ5: (360i) AC770Y-F000-G00-31 SafeQ6: (450i) AC770Y0-F000-G00-D0 General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
|
Konica Minolta | C750i | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested ROM version SAFEQ5: G00-35 SAFEQ6: G00-34 / G00-35 General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Gen2 browser)
|
Konica Minolta | 550i | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 / MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controller ROM version AC740Y0-0100-G00-31 General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Gen2 browser)
|
Konica Minolta | 650i | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 / MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controller ROM version AC740Y0-0100-G00-31 General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
|
Konica Minolta | 750i | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 / MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested ROM version ACV70Y0-F000-G00-35 General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
|
Konica Minolta | C650i | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controller ROM version AA7N0Y0-0100-G00-2B(00) General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
|
Konica Minolta | C550i | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controller ROM version AA7N0Y0-0100-G00-2B(00) General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
|
Konica Minolta | C450i | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version AA7N0Y0-0100-G00-2B(00) General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
|
Konica Minolta | bizhub 4000i | bizhub | No |
No |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A4-4000 | No |
Yes |
Recommended driver: MIFALSELTA-PRN-BW-A4-4000 Limitations: If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 Build 41
The model is compatible with the Embedded Terminal for Konica Minolta BSI
Build 75 is required to use the Embedded Terminal for Konica Minolta BSI
|
Konica Minolta | 5000i | bizhub | No |
No |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A4-4000 | No |
Yes |
Recommended driver: MIFALSELTA-PRN-BW-A4-4000 Limitations: If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | No |
Yes |
Yes |
No |
No |
Yes |
LD device from YSoft SafeQ 6 Build 41
The model is compatible with the Embedded Terminal for Konica Minolta BSI
Build 75 is required to use the Embedded Terminal for Konica Minolta BSI
|
Konica Minolta | 5020i | bizhub | Yes |
No |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A4-4020 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A4-4020 Limitations: Status detection during scan is FALSEt supported. If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. All paper trays have to have some paper present. | No |
Yes |
Yes |
No |
No |
Yes |
LD device from YSoft SafeQ 6 Build 41
The model is compatible with the Embedded Terminal for Konica Minolta BSI
Build 75 is required to use the Embedded Terminal for Konica Minolta BSI
|
Konica Minolta | 4020i | bizhub | Yes |
No |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A4-4020 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A4-4020 Limitations: Status detection during scan is FALSEt supported. If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. All paper trays have to have some paper present. | No |
Yes |
Yes |
No |
No |
Yes |
LD device from YSoft SafeQ 6 Build 41
The model is compatible with the Embedded Terminal for Konica Minolta BSI
Build 75 is required to use the Embedded Terminal for Konica Minolta BSI
|
Konica Minolta | bizhub 226i | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-XXXE-V3 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. | Yes |
Yes |
No |
No |
Yes |
Yes |
Logout by card requires DIP SW value change. Please ask KM internally for DIP SW value.
|
|
Konica Minolta | 246i | bizhub | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-XXXE-V3 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. | Yes |
Yes |
No |
No |
Yes |
Yes |
Logout by card requires DIP SW value change. Please ask KM internally for DIP SW value.
|
Konica Minolta | 266i | bizhub | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-XXXE-V3 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Logout by card requires DIP SW value change. Please ask KM internally for DIP SW value.
|
Konica Minolta | 306i | bizhub | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-XXXE-V3 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. | Yes |
Yes |
No |
No |
Yes |
Yes |
Logout by card requires DIP SW value change. Please ask KM internally for DIP SW value.
|
Konica Minolta | C281 | bizhub | Yes |
Yes |
Yes |
Yes |
No |
MIFALSELTA-MFP-COL-A3-C221-M1 / MIFALSELTA-MFP-COL-A3-C221-M2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-C221-M1 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 2 colors copy is accounted as a full-color copy. This driver is for "total counter mode 1" MFD setting. MIFALSELTA-MFP-COL-A3-C221-M2 here is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 2 colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) This driver is for "total counter mode 2" MFD setting. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
Konica Minolta | C221s | bizhub | Yes |
Yes |
Yes |
Yes |
No |
MIFALSELTA-MFP-COL-A3-C221-M1 / MIFALSELTA-MFP-COL-A3-C221-M2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-C221-M1 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 2 colors copy is accounted as a full-color copy. This driver is for "total counter mode 1" MFD setting. MIFALSELTA-MFP-COL-A3-C221-M2 here is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 2 colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) This driver is for "total counter mode 2" MFD setting. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
Konica Minolta | C221 | bizhub | Yes |
Yes |
Yes |
Yes |
No |
MIFALSELTA-MFP-COL-A3-C221-M1 / MIFALSELTA-MFP-COL-A3-C221-M2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-C221-M1 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 2 colors copy is accounted as a full-color copy. This driver is for "total counter mode 1" MFD setting. MIFALSELTA-MFP-COL-A3-C221-M2 here is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 2 colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) This driver is for "total counter mode 2" MFD setting. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
Konica Minolta | C3351 | bizhub | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C3850 | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-BIZHUB-C3850 | Yes |
Yes |
No |
No |
Yes |
Yes |
To use Scan Workflow of SafeQ6 on Native OpenAPI Terminal, use the FW: A92E0Y0-F000-G00-K8 or later.
|
Konica Minolta | C3851 | bizhub | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C3850 | Yes |
No |
Recommended driver: MIFALSELTA-MFP-COL-BIZHUB-C3850 | Yes |
Yes |
No |
No |
Yes |
Yes |
To use Scan Workflow of SafeQ6 on Native OpenAPI Terminal, use the FW: A92E0Y0-F000-G00-K8 or later.
|
Konica Minolta | 558 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. | Yes |
Yes |
No |
No |
Yes |
Yes |
|
Konica Minolta | 458 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. | Yes |
Yes |
No |
No |
Yes |
Yes |
|
Konica Minolta | 368 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. | Yes |
Yes |
No |
No |
Yes |
Yes |
|
Konica Minolta | 308 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. | Yes |
Yes |
No |
No |
Yes |
Yes |
|
Konica Minolta | bizhub C658 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5: A79J0Y0-0100-G00-10
Tested FW for SafeQ 4: G00-21
(SafeQ5 GEN1/SafeQ6 GEN2) Authentication cache not supported.
(SafeQ5 GEN1/SafeQ6 GEN2) Attempting to scan to “JPEG in BW” using SafeQ Scan Workflow does not start scanning because it is unsupported combination by bizhub
|
Konica Minolta | bizhub C558 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5: A79J0Y0-0100-G00-10
Tested FW for SafeQ 4: G00-21
(SafeQ5 GEN1/SafeQ6 GEN2) Authentication cache not supported.
(SafeQ5 GEN1/SafeQ6 GEN2) Attempting to scan to “JPEG in BW” using SafeQ Scan Workflow does not start scanning because it is unsupported combination by bizhub
|
Konica Minolta | bizhub C458 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5: A79J0Y0-0100-G00-10
Tested FW for SafeQ 4: G00-21
(SafeQ5 GEN1/SafeQ6 GEN2) Authentication cache not supported.
(SafeQ5 GEN1/SafeQ6 GEN2) Attempting to scan to “JPEG in BW” using SafeQ Scan Workflow does not start scanning because it is unsupported combination by bizhub.
|
Konica Minolta | bizhub PRO 958 | bizhub | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5: A7950Y0-0100-G00-17 (TE)
|
Konica Minolta | bizhub 958 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
No |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5: A7950Y0-0100-G00-17 (TE)
|
Konica Minolta | 808 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5: A7950Y0-0100-G00-17 (TE)
|
Konica Minolta | 758 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version for SafeQ5: A7950Y0-0100-G00-17 (TE)
(SafeQ5 GEN1/SafeQ6 GEN2) Authentication cache not supported.
(SafeQ5 GEN1/SafeQ6 GEN2) Attempting to scan to “JPEG in BW” using SafeQ Scan Workflow does not start scanning because it is unsupported combination by bizhub.
|
Konica Minolta | bizhub PRO 1100 | bizhub PRO | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-BH1100 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-BH1100 Limitations: Additional busy state recognition from number of active jobs. This driver is suitable for Mode 1 accounting only. Device is FALSEt ready in sleep mode. Direct print is FALSEt possible when device is blocked by blocking cable. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser and Native fully supported with later FW versions.
Older FW version have following limitations:
Native:
Self card assignment is not supported.
Accounting of scanning is supported from SafeQ 5 Maintenance Update 30.
User cannot log in when he has more than one billing code.
Payment System: User is able to scan without credit / Device do not block user with no credit while scanning.
Browser:
Not currently supported.
Tested Controler ROM version:
Controller P1: A7990Y0-00P1-G00-20
Controller P2: A799011-00P2-G00-10
|
Konica Minolta | bizhub PRESS C1085 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-PRESS-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-BIZHUB-PRESS-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 1 color copy is accounted as a full-color copy. Driver can be set for offline copy accounting. This driver is for "total counter mode 1" MFD setting. This driver is for a device with IC-602 MIFALSELTA-MFP-COL-BIZHUB-PRESS-M2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 1 color copy is accounted as a full-color copy. Driver can be set for offline copy accounting. This driver is for "total counter mode 2" MFD setting. This driver is for a device with IC-602 | No |
Untested |
No |
No |
No |
No |
Billing code selection and card self-registration is not supported and ends with an error.
|
Konica Minolta | bizhub PRESS C1100 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-PRESS-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-BIZHUB-PRESS-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 1 color copy is accounted as a full-color copy. Driver can be set for offline copy accounting. This driver is for "total counter mode 1" MFD setting. This driver is for a device with IC-602 MIFALSELTA-MFP-COL-BIZHUB-PRESS-M2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 1 color copy is accounted as a full-color copy. Driver can be set for offline copy accounting. This driver is for "total counter mode 2" MFD setting. This driver is for a device with IC-602 | No |
Untested |
No |
No |
No |
No |
Billing code selection and card self-registration is not supported and ends with an error.
|
Konica Minolta | bizhub PRESS C1070P | bizhub | No |
Yes |
Yes |
Yes |
No |
MIFALSELTA-PRN-COL-A3-C1070P | No |
No |
Recommended driver:MIFALSELTA-PRN-COL-A3-C1070P Limitations:There is a 3 seconds timeout after print.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | bizhub PRESS C1060P | bizhub | No |
Yes |
Yes |
Yes |
No |
MIFALSELTA-PRN-COL-A3-C1070P | No |
No |
Recommended driver:MIFALSELTA-PRN-COL-A3-C1070P Limitations:There is a 3 seconds timeout after print.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | bizhub PRESS C1070 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to mode 2. | Yes |
Untested |
No |
No |
Yes |
Yes |
Native:
Configuration with Fiery Image Controller is not supported.
Self card assignment is not supported.
Accounting of scanning is supported from SafeQ 5 Maintenance Update 30.
User cannot log in when he has more than one billing code.
Payment System:
User is able to scan without credit / Device do not block user with no credit while scanning.
Browser:
Not supported.
Tested Controler ROM version: G00-20
|
Konica Minolta | bizhub PRESS C1060 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | bizhub PRESS C1050 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | bizhub C3110 | bizhub | Yes |
No |
Yes |
Yes |
No |
MIFALSELTA-MFP-COL-A4-C3110 | No |
No |
Recommended driver:MIFALSELTA-MFP-COL-A4-C3110 Limitations: FALSE limitations LD license eligible | No |
Untested |
Yes |
No |
No |
No |
Device does not have a blocking interface.
|
Konica Minolta | bizhub C3100P | bizhub | No |
No |
Yes |
Yes |
No |
MIFALSELTA-PRN-COL-A4-C3100P | No |
No |
Recommended driver:MIFALSELTA-PRN-COL-A4-C3100P Limitations: FALSE limitations LD license eligible | No |
Untested |
Yes |
No |
No |
No |
|
Konica Minolta | bizhub 4000P | bizhub | No |
No |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A4-BIZHUB-3300P | No |
No |
Recommended driver: MIFALSELTA-PRN-BW-A4-BIZHUB-3300P Limitations: Duplex print is accounted according to parser from job information. There is a 4 seconds timeout after print. Device is FALSEt fully compatible with SafeQ Rules Based Engine - device may print incorrect number of copies or request paper from different paper tray. | No |
Untested |
Yes |
No |
No |
No |
|
Konica Minolta | bizhub 3301P | bizhub | No |
No |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A4-BIZHUB-3300P | No |
No |
Recommended driver: MIFALSELTA-PRN-BW-A4-BIZHUB-3300P Limitations: Duplex print is accounted according to parser from job information. There is a 4 seconds timeout after print. Device is FALSEt fully compatible with SafeQ Rules Based Engine - device may print incorrect number of copies or request paper from different paper tray. | No |
Untested |
Yes |
No |
No |
No |
|
Konica Minolta | bizhub 4700P | bizhub | No |
No |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A4-BIZHUB-3300P | No |
No |
Recommended driver: MIFALSELTA-PRN-BW-A4-BIZHUB-3300P Limitations: Duplex print is accounted according to parser from job information. There is a 4 seconds timeout after print. Device is FALSEt fully compatible with SafeQ Rules Based Engine - device may print incorrect number of copies or request paper from different paper tray. | No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 MU17.
|
Konica Minolta | bizhub 3300P | bizhub | No |
No |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A4-BIZHUB-3300P | No |
No |
Recommended driver: MIFALSELTA-PRN-BW-A4-BIZHUB-3300P Limitations: Duplex print is accounted according to parser from job information. There is a 4 seconds timeout after print. | No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 MU17.
|
Konica Minolta | C240 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver:MIFALSELTA-BIZC250 Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | C210 | bizhub | Yes |
Yes |
Yes |
Yes |
No |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | C3350 | bizhub | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C3850 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-BIZHUB-C3850 Limitations: Required firmware for blocking: A3GN30G0206-999 or newer. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:Job details are not displayed with tested version of firmware.Device cancels Job by going to sleep mode. USB card reader:Required firmware: A3GN30G0123-951 or newer. Browser:Required firmware: A3GN30G0607-W99 or newer Tested Controller ROM version:A3GN30G0116-999A3GN30G0123-999A3GN30GJ607-951A3GN30G0607-W99 Recommended Controller ROM version: A3GN30G0142-999 Supports SafeQ 6 Basic and Advanced Finishing Options. SafeQ 6 Universal Print Driver compatible.
|
Konica Minolta | C3850 | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C3850 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-BIZHUB-C3850 Limitations: Required firmware for blocking: A3GN30G0206-999 or newer. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:Job details are not displayed with tested version of firmware.Device cancels Job by going to sleep mode. USB card reader:Required firmware: A3GN30G0123-951 or newer. Browser:Required firmware: A3GN30G0607-W99 or newer Tested Controller ROM version:A3GN30G0116-999A3GN30G0123-999A3GN30GJ607-951A3GN30G0607-W99 Recommended Controller ROM version: A3GN30G0142-999 Supports SafeQ 6 Basic and Advanced Finishing Options. SafeQ 6 Universal Print Driver compatible.
|
|
Konica Minolta | 3320 | Yes |
No |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 Limitations: There is 1 second timeout after copy and print. Blocking of device is FALSEt currently supported by firmware. Device is FALSEt fully compatible with SafeQ Rules Based Engine - device may print incorrect number of copies or request paper from different paper tray. | No |
Untested |
Yes |
No |
No |
No |
||
Konica Minolta | 4020 | Yes |
No |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 Limitations: There is 1 second timeout after copy and print. Blocking of device is FALSEt currently supported by firmware. Device is FALSEt fully compatible with SafeQ Rules Based Engine - device may print incorrect number of copies or request paper from different paper tray. | No |
Untested |
Yes |
No |
No |
No |
||
Konica Minolta | 4050 | bizhub | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 | No |
Yes |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 Limitations: There is 1 second timeout after copy and print. bizhub 4050: Required firmware for blocking: A6F730G0236-999 or newer. Revision of motherboard from serial number A6VF021006606 (valid only for Europe). bizhub 4750: Required firmware for blocking: A6F730G0236-999 or newer. Revision of motherboard from serial number A6VF021001836 (valid only for Europe). Device is FALSEt fully compatible with SafeQ Rules Based Engine - device may print incorrect number of copies or request paper from different paper tray. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
Job details are not displayed with tested version of firmware.
Recommended firmware: A6F730G0236-999 or newer.
USB card reader: Required firmware: A6F730G0121-999 or newer.
Device cancels Job by going to sleep mode.
Browser:
Recommended firmware A6F730G0804-W51 or later.
Tested Controler ROM version: A6F730G0110-999
Device is not fully compatible with SafeQ Rules Based Engine - device may print incorrect number of copies or request paper from different paper tray.
|
Konica Minolta | 4750 | bizhub | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 | No |
Yes |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 Limitations: There is 1 second timeout after copy and print. bizhub 4050: Required firmware for blocking: A6F730G0236-999 or newer. Revision of motherboard from serial number A6VF021006606 (valid only for Europe). bizhub 4750: Required firmware for blocking: A6F730G0236-999 or newer. Revision of motherboard from serial number A6VF021001836 (valid only for Europe). Device is FALSEt fully compatible with SafeQ Rules Based Engine - device may print incorrect number of copies or request paper from different paper tray. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
Job details are not displayed with tested version of firmware.
Recommended firmware: A6F730G0236-999 or newer.
USB card reader: Required firmware: A6F730G0121-999 or newer.
Device cancels Job by going to sleep mode.
Browser:
Recommended firmware A6F730G0804-W51 or later.
Tested Controler ROM version: A6F730G0110-999
Device is not fully compatible with SafeQ Rules Based Engine - device may print incorrect number of copies or request paper from different paper tray.
|
Konica Minolta | 4750DN | Magicolor | No |
No |
Yes |
Yes |
No |
MIFALSELTA-MFP-COL-DUP-MC-4750 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 652 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-A3-DUP-BIZ552 | No |
No |
Recommended driver:MIFALSELTA-MFP-A3-DUP-BIZ552 Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | Yes |
Yes |
No |
No |
Yes |
No |
||
Konica Minolta | bizhub 552 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-A3-DUP-BIZ552 | No |
No |
Recommended driver:MIFALSELTA-MFP-A3-DUP-BIZ552 Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | Yes |
Yes |
No |
No |
Yes |
No |
||
Konica Minolta | 240f | bizhub | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-240f | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-240f Limitations:Counters for copy and print are shared. There is FALSEt counter for duplex print/copy. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 7300EN | Magicolor | No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | 4695MF | Magicolor | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A4-4695 | No |
No |
Recommended driver:MIFALSELTA-MFP-COL-A4-4695 Limitations:There is 1 second timeout after copy and print. Device may be after printing/copying too long in BUSY state, which causes unwanted delay during printing process (cca. 20 seconds). | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 4690MF | Magicolor | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A4-4695 | No |
No |
Recommended driver:MIFALSELTA-MFP-COL-A4-4695 Limitations:There is 1 second timeout after copy and print. Device may be after printing/copying too long in BUSY state, which causes unwanted delay during printing process (cca. 20 seconds). | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 2430DL | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-2430 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 25e | bizhub | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-25E-BUSY | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-25E-BUSY Limitations:Firmware version KM25eEUR130411 has to be used.There is 2 second timeout after print and copy.Duplex print is recognized from a job.Each duplex copy is accounted as simplex.Each printed/copy duplex page is accounted as two pages. Status detection is based on vendor provided busy status specification. Opened doors, opened trays and empty paper are considered as device busy status. LD license eligible | No |
Untested |
Yes |
No |
No |
No |
There is 2 second timeout after print and copy. Duplex print is recognized from a job. Each duplex copy is accounted as simplex. Each printed/copy duplex page is accounted as two pages. Status detection is based on vendor provided busy status specification. Open doors, open trays and empty paper are considered as device busy status. Firmware version KM25eEUR130411 has to be used.
|
Konica Minolta | 361i | bizhub | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | C4001i | bizhub | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|||
Konica Minolta | C3351i | bizhub | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
LD device since SAFEQ 6 Build 95. |
||
Konica Minolta | AccurioPress C7090 | AccurioPress | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Yes |
No |
No |
Yes |
No |
|||
Konica Minolta | bizhub 308e | bizhub | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Authentication cache not working.
|
||
Konica Minolta | bizhub 368e | bizhub | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
SafeQ4 tested with FWG00-W4
(SafeQ6 GEN2) Authentication cache not supported.
(SafeQ5 GEN1/SafeQ6 GEN2) Attempting to scan to “JPEG in BW” using SafeQ Scan Workflow does not start scanning because it is unsupported combination by bizhub.
|
||
Konica Minolta | bizhub 458e | bizhub | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Firmware of tested device: GC2-09
SafeQ4 tested with FWG00-W4
(SafeQ6 GEN2) Authentication cache not supported.
(SafeQ5 GEN1/SafeQ6 GEN2) Attempting to scan to “JPEG in BW” using SafeQ Scan Workflow does not start scanning because it is unsupported combination by bizhub.
|
||
Konica Minolta | bizhub 558e | bizhub | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Firmware of tested device: GC2-09
SafeQ4 tested with FWG00-W4
Authentication cache not working.
(SafeQ5 GEN1/SafeQ6 GEN2) Attempting to scan to “JPEG in BW” using SafeQ Scan Workflow does not start scanning because it is unsupported combination by bizhub.
|
||
Konica Minolta | bizhub 658e | bizhub | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Firmware of tested device: GC2-09
SafeQ4 tested with FWG00-W4
Authentication cache not working.
(SafeQ5 GEN1/SafeQ6 GEN2) Attempting to scan to “JPEG in BW” using SafeQ Scan Workflow does not start scanning because it is unsupported combination by bizhub.
|
||
Konica Minolta | C759 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Firmware:
G00-09
|
||
Konica Minolta | C659 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Firmware:
G00-09
|
||
Konica Minolta | Bizhub 602 | bizhub | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | Bizhub 502 | bizhub | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | KIP 700M | KIP | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
Can be used only with Off-line (parser) accounting
|
||
Konica Minolta | Fiery IC-413 | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Konica Minolta | Fiery IC-412 | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Konica Minolta | C65hc | bizhub | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | PRO C6501 | bizhub | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | 267 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Recommended latest firmware (above G00-24).
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
Konica Minolta | 4700i | bizhub | No |
No |
No |
Yes |
Yes |
MIFALSELTA-PRN-BW-A4-4700i | Yes |
Yes |
There is a 3 seconds timeout after print. | Yes |
Yes |
Yes |
No |
Yes |
Yes |
Tested ROM version ACTA0Y0-F000-GX1-19(00) General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Native Terminal) "Card and PIN or Username/password" authentication method shows duplicate instruction on the interface when the device is set in European languages (Defect SBT-2134).
|
Konica Minolta | C226i | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested ROM version C287i Japan model - SafeQ6: ACM10Y0-0100-G00-18 C257i EU model - SafeQ5: ACM10Y0-0100-G00-16 General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. (Browser Terminal) The print job preview is not loaded in the job detail information page, the preview layout is randomly broken, connection with the server fails after job preview dispaly attemp and the browser is closed. To workaround "connection failure", "preview-enabled" shall be disabled. Or use the NATIVE OpenAPI Terminal(LIMIT-500) SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Native Terminal) "Card and PIN or Username/password" authentication method shows duplicate instruction on the interface when the device is set in European languages (Defect SBT-2134).
|
Konica Minolta | C266i | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested ROM version
C287i Japan model - SafeQ6: ACM10Y0-0100-G00-18
C257i EU model - SafeQ5: ACM10Y0-0100-G00-16
General
When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a.
Logout by card requires DIP SW 215 HEX 08.
SafeQ5
(Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout.
(Browser Terminal) The print job preview is not loaded in the job detail information page, the preview layout is randomly broken, connection with the server fails after job preview dispaly attemp and the browser is closed. To workaround "connection failure", "preview-enabled" shall be disabled. Or use the NATIVE OpenAPI Terminal(LIMIT-500)
SafeQ6
(Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Native Terminal) "Card and PIN or Username/password" authentication method shows duplicate instruction on the interface when the device is set in European languages (Defect SBT-2134).
(Gen2 browser) When using SafeQ6 Gen2 terminal, it is recommended to disable certificate validation or create a custom certificate having SAN(Subject Alternative Name) and use it instead and register to bizhub. Terminal server default certificate does not have SAN value.
|
Konica Minolta | C286i | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested ROM version C287i Japan model - SafeQ6: ACM10Y0-0100-G00-18 C257i EU model - SafeQ5: ACM10Y0-0100-G00-16 General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. (Browser Terminal) The print job preview is not loaded in the job detail information page, the preview layout is randomly broken, connection with the server fails after job preview dispaly attemp and the browser is closed. To workaround "connection failure", "preview-enabled" shall be disabled. Or use the NATIVE OpenAPI Terminal(LIMIT-500) SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Native Terminal) "Card and PIN or Username/password" authentication method shows duplicate instruction on the interface when the device is set in European languages (Defect SBT-2134).
|
Konica Minolta | C227i | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested ROM version C287i Japan model
|
Konica Minolta | C257i | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested ROM version C287i Japan model - SafeQ6: ACM10Y0-0100-G00-18 C257i EU model - SafeQ5: ACM10Y0-0100-G00-16 General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. (Browser Terminal) The print job preview is not loaded in the job detail information page, the preview layout is randomly broken, connection with the server fails after job preview dispaly attemp and the browser is closed. To workaround "connection failure", "preview-enabled" shall be disabled. Or use the NATIVE OpenAPI Terminal(LIMIT-500) SafeQ6 (Native TE only) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Native TE) "Card and PIN or Username/password" authentication method shows duplicate instruction on the interface when the device is set in European languages (Defect SBT-2134).
|
Konica Minolta | C287i | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested ROM version C287i Japan model - SafeQ6: ACM10Y0-0100-G00-18 C257i EU model - SafeQ5: ACM10Y0-0100-G00-16 General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. (Browser Terminal) The print job preview is not loaded in the job detail information page, the preview layout is randomly broken, connection with the server fails after job preview dispaly attemp and the browser is closed. To workaround "connection failure", "preview-enabled" shall be disabled. Or use the NATIVE OpenAPI Terminal(LIMIT-500) SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Native Terminal) "Card and PIN or Username/password" authentication method shows duplicate instruction on the interface when the device is set in European languages (Defect SBT-2134).
|
Konica Minolta | 4750i | bizhub | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4752 | Yes |
No |
There is 3 second timeout after copy and print. | Yes |
Yes |
Yes |
No |
Yes |
Yes |
Tested ROM version ACT-90Y0-F000-GX1-19(00) General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Native Terminal) "Card and PIN or Username/password" authentication method shows duplicate instruction on the interface when the device is set in European languages (Defect SBT-2134).
|
Konica Minolta | 4050i | bizhub | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4752 | Yes |
Yes |
There is 3 second timeout after copy and print. | Yes |
Yes |
Yes |
No |
Yes |
Yes |
Tested ROM version ACT-90Y0-F000-GX1-19(00) General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Native Terminal) "Card and PIN or Username/password" authentication method shows duplicate instruction on the interface when the device is set in European languages (Defect SBT-2134).
|
Konica Minolta | 300i | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 / MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested ROM version SafeQ5: (360i) AC770Y-F000-G00-31 SafeQ6: (450i) AC770Y0-F000-G00-D0 General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
|
Konica Minolta | 360i | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 / MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE-V3 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested ROM version SafeQ5: (360i) AC770Y-F000-G00-31 SafeQ6: (450i) AC770Y0-F000-G00-D0 General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
|
Konica Minolta | C3320i | bizhub | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A4-C3350i | No |
Yes |
There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. | Yes |
Yes |
Yes |
No |
Yes |
Yes |
Tested Controler ROM version AAJT0Y0-F000-G00-28 Common for SafeQ5 and SafeQ6(MFD limitation with the tested FW version) MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. This bug will be fixed by IT6v2.0 mass-production FW that is scheduled for release in early October. Classic UI does not have this issue. When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0 which are not enabled by default on the device. To use TLS1.1 or TLS1.2, set kmOpenApiVersion to 4-13a(default of SafeQ6). SafeQ5 (Native TE only) Auto logout by user defined timeout does not work. (Browser TE) Auto logout by user defined time out only logges out a user from the SQ application. A user needs to press MFD's logout button to logout. System Auto Reset shall be used instead for auto logout. Logout by card requires DIP SW value change. Please ask KM internally for DIP SW value. SafeQ6 (Native TE only) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Gen2 browser) Certificate validation shall be disabled or the MFD loops showing certificate validation message and behaves strangely when trying to logout. Registering a certificate from the MFD's browser cannot register the cert. Uploading a cert from the administration web also does not solve this behaviour Logout by card requires DIP SW value change. Please ask KM internally for DIP SW value. LD device from YSoft SafeQ 6 Build 47
|
Konica Minolta | C4050i | bizhub | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A4-C3350i | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A4-C3350i Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. | Yes |
Yes |
No |
No |
Yes |
Yes |
Common Limitations:
MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. Classic UI does not have this issue.
SafeQ5
Logout by card does not work.
|
Konica Minolta | bizhub C3350i | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A4-C3350i | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A4-C3350i Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. | Yes |
Yes |
Yes |
No |
Yes |
Yes |
Common Limitations:
MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. Classic UI does not have this issue.
SafeQ5
Logout by card does not work.
LD device from YSoft SafeQ 6 Build 47
|
|
Konica Minolta | C360i | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version AA2J0Y0-0100-G00-23(00) General When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. Logout by card requires DIP SW 215 HEX 08. SafeQ5 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout. SafeQ6 (Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
|
Konica Minolta | C300i | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested Controller ROM version AA2J0Y0-0100-G00-23(00) Common for SafeQ5 and SafeQ6(MFD limitation with the tested FW version) MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. This bug will be fixed by IT6v2.0 mass-production FW that is scheduled for release in early October. Classic UI does not have this issue. When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. When using SafeQ6 Gen2 terminal, certificate validation shall be disabled in the MFD or the MFD loops the certificate validation message on the browser on logout attempt. Or the solution is to create a custom certificate having SAN(Subject Alternative Name) and use it instead and register to bizhub. Terminal server default certificate does not have SAN value and cannot be trusted so the behaviour above occurs. SafeQ5 (Native TE only) Auto logout by user defined timeout does not work. (Gen2 browser) . Logout by card requires DIP SW SW 215 HEX 08. SafeQ6 (Native TE only) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. Logout by card requires DIP SW SW 215 HEX 08.
|
Konica Minolta | C250i | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3 / MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested Controler ROM version AA2J0Y0-0100-G00-23(00) Common for SafeQ5 and SafeQ6(MFD limitation with the tested FW version) MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. This bug will be fixed by IT6v2.0 mass-production FW that is scheduled for release in early October. Classic UI does not have this issue. When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0. Older SDK does not support TLS1.1 and TLS1.2. To use TLS1.1 or TLS1.2, use 4-13a. SafeQ5 (Native TE only) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Browser TE) Auto logout by user defined time out only logges out a user from the SQ application. A user needs to press MFD's logout button to logout. Logout by card requires DIP SW SW 215 HEX 08. SafeQ6 (Native TE only) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout. (Gen2 browser) Logout by card requires DIP SW SW 215 HEX 08.
|
Konica Minolta | C3300i | bizhub | No |
No |
Yes |
Yes |
No |
MIFALSELTA-PRN-COL-A4-C3300 | No |
Yes |
Recommended driver: MIFALSELTA-PRN-COL-A4-C3300 Limitations: There is a 3 seconds timeout after print. Each 2 colors print is accounted as a full-color print. | Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Device has limited OpenAPI - Application icon is not visible, can be added manually via web interface of the device.
Minimum required firmware: GC1-73
Scan application is not supported.
LD device from YSoft SafeQ 6 Build 41
Since GC1-7B it is possible to add YSoft SafeQ application to device panel manually after installation. The icon will stay in place even after reinstallation of terminal.
|
Konica Minolta | bizhub C4000i | bizhub | No |
No |
Yes |
Yes |
No |
MIFALSELTA-PRN-COL-A4-C3300 | Yes |
Yes |
Recommended driver: MIFALSELTA-PRN-COL-A4-C3300 Limitations: There is a 3 seconds timeout after print. Each 2 colors print is accounted as a full-color print. | Yes |
Yes |
Yes |
Yes |
Yes |
Yes |
Device has limited OpenAPI - Application icon is not visible, can be added manually via web interface of the device.
Minimum required firmware: GC1-73
Scan application is not supported.
LD device from YSoft SafeQ 6 Build 41
|
Konica Minolta | 6136P | AccurioPress | No |
Yes |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A3-6120 | No |
Yes |
Recommended driver: MIFALSELTA-PRN-BW-A3-6120 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. This driver is for "total counter mode 2" MFD setting. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | C6085 | AccurioPress | No |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-A3-C6100-M1 | No |
Yes |
Recommended driver: MIFALSELTA-PRN-COL-A3-C6100-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. This driver is for "total counter mode 1" MFD setting. For device without PF-711 unit. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | C6100 | AccurioPress | No |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-A3-C6100-M1 | No |
Yes |
Recommended driver: MIFALSELTA-PRN-COL-A3-C6100-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. This driver is for "total counter mode 1" MFD setting. For device without PF-711 unit. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | C83hc | AccurioPress | No |
Yes |
Yes |
No |
No |
MIFALSELTA-PRN-COL-A3-C1070P | No |
No |
Recommended driver: MIFALSELTA-PRN-COL-A3-C1070P Limiations: There is a 3 seconds timeout after print. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. C3000/C73/C83 series supporter with internal controller IC-605. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | C73hc | AccurioPress | No |
Yes |
Yes |
Yes |
No |
MIFALSELTA-PRN-COL-A3-C1070P | No |
No |
Recommended driver: MIFALSELTA-PRN-COL-A3-C1070P Limiations: There is a 3 seconds timeout after print. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. C3000/C73/C83 series supporter with internal controller IC-605. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | C3080P | AccurioPress | No |
Yes |
Yes |
Yes |
No |
MIFALSELTA-PRN-COL-A3-C1070P | Yes |
Yes |
Recommended driver: MIFALSELTA-PRN-COL-A3-C1070P Limiations: There is a 3 seconds timeout after print. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. C3000/C73/C83 series supporter with internal controller IC-605. | Yes |
Yes |
No |
No |
Yes |
Yes |
SafeQ6 GEN2 terminal is not certified.
(AccurioPress Postscript driver): RBE and Finishing options are not supported.
(Device limitation): Logout with card does not initiate logout
(Device limitation): When the device language is in single byte languages(English), billing code description in multibyte language are not displayed.
(Device limitation):
Sleep mode is not supported by the device, but Power Save mode and Shut off mode.
Shut off mode: Does not supply power to card reader, so card swipe does nothing.
Power Save mode: When card swipe occurs, login process is triggered on the backgroud and user is already logged in, however Panel does not turn on. User need to manually press HW Power Save button to turn on the panel.
(Device limitation): Authentication cache is not supported.
Authentication by integrated keypad is not supported.
|
Konica Minolta | C3070P | AccurioPress | No |
Yes |
Yes |
Yes |
No |
MIFALSELTA-PRN-COL-A3-C1070P | No |
No |
Recommended driver: MIFALSELTA-PRN-COL-A3-C1070P Limiations: There is a 3 seconds timeout after print. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. C3000/C73/C83 series supporter with internal controller IC-605. | Yes |
Yes |
No |
No |
Yes |
Yes |
SafeQ6 GEN2 terminal is not certified.
(AccurioPress Postscript driver): RBE and Finishing options are not supported.
(Device limitation): Logout with card does not initiate logout
(Device limitation): When the device language is in single byte languages(English), billing code description in multibyte language are not displayed.
(Device limitation):
Sleep mode is not supported by the device, but Power Save mode and Shut off mode.
Shut off mode: Does not supply power to card reader, so card swipe does nothing.
Power Save mode: When card swipe occurs, login process is triggered on the backgroud and user is already logged in, however Panel does not turn on. User need to manually press HW Power Save button to turn on the panel.
(Device limitation): Authentication cache is not supported.
Authentication by integrated keypad is not supported.
|
Konica Minolta | C3070L | AccurioPrint | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. C3000 series supporter with internal controller IC-605. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested model and FW version
Browser W A9VE0Y0-00W1-G00-20
Controller P1 A9VE0Y0-00P1-G00-20
Controller P2 A9VE001-00P2-G00-20
SafeQ6 GEN2 terminal is not certified.
(AccurioPress Postscript driver): RBE and Finishing options are not supported.
(Device limitation): Logout with card does not initiate logout
(Device limitation): When the device language is in single byte languages(English), billing code description in multibyte language are not displayed.
(Device limitation):
Sleep mode is not supported by the device, but Power Save mode and Shut off mode.
Shut off mode: Does not supply power to card reader, so card swipe does nothing.
Power Save mode: When card swipe occurs, login process is triggered on the backgroud and user is already logged in, however Panel does not turn on. User need to manually press HW Power Save button to turn on the panel.
(Device limitation): Authentication cache is not supported.
Authentication by integrated keypad is not supported.
|
Konica Minolta | C3070 | AccurioPress | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. C3000 series supporter with internal controller IC-605. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested model and FW version
Browser W A9VE0Y0-00W1-G00-20
Controller P1 A9VE0Y0-00P1-G00-20
Controller P2 A9VE001-00P2-G00-20
SafeQ6 GEN2 terminal is not certified.
(AccurioPress Postscript driver): RBE and Finishing options are not supported.
(Device limitation): Logout with card does not initiate logout
(Device limitation): When the device language is in single byte languages(English), billing code description in multibyte language are not displayed.
(Device limitation):
Sleep mode is not supported by the device, but Power Save mode and Shut off mode.
Shut off mode: Does not supply power to card reader, so card swipe does nothing.
Power Save mode: When card swipe occurs, login process is triggered on the backgroud and user is already logged in, however Panel does not turn on. User need to manually press HW Power Save button to turn on the panel.
(Device limitation): Authentication cache is not supported.
Authentication by integrated keypad is not supported.
|
Konica Minolta | C3080 | AccurioPress | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. C3000 series supporter with internal controller IC-605. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested model and FW version
Browser W A9VE0Y0-00W1-G00-20
Controller P1 A9VE0Y0-00P1-G00-20
Controller P2 A9VE001-00P2-G00-20
SafeQ6 GEN2 terminal is not certified.
(AccurioPress Postscript driver): RBE and Finishing options are not supported.
(Device limitation): Logout with card does not initiate logout
(Device limitation): When the device language is in single byte languages(English), billing code description in multibyte language are not displayed.
(Device limitation):
Sleep mode is not supported by the device, but Power Save mode and Shut off mode.
Shut off mode: Does not supply power to card reader, so card swipe does nothing.
Power Save mode: When card swipe occurs, login process is triggered on the backgroud and user is already logged in, however Panel does not turn on. User need to manually press HW Power Save button to turn on the panel.
(Device limitation): Authentication cache is not supported.
Authentication by integrated keypad is not supported.
|
Konica Minolta | bizhub 4752 | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4752 | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4752 Limitations: There is 3 second timeout after copy and print. | Yes |
Yes |
No |
No |
Yes |
Yes |
||
Konica Minolta | 4052 | bizhub | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4752 | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4752 Limitations: There is 3 second timeout after copy and print. | Yes |
Yes |
Yes |
No |
Yes |
Yes |
SafeQ4 tested with the device FW version G00-12
LD device from YSoft SafeQ 6 Build 47
|
Konica Minolta | bizhub 3622 | Yes |
No |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 | No |
No |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 Limitations: There is 1 second timeout after copy and print. bizhub 4050: Required firmware for blocking: A6F730G0236-999 or newer. Revision of motherboard from serial number A6VF021006606 (valid only for Europe). bizhub 4750: Required firmware for blocking: A6F730G0236-999 or newer. Revision of motherboard from serial number A6VF021001836 (valid only for Europe). | No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | bizhub 4422 | Yes |
No |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 | No |
No |
MIFALSELTA-MFP-BW-A4-DUP-BIZHUB-4750 Limitations: There is 1 second timeout after copy and print. bizhub 4050: Required firmware for blocking: A6F730G0236-999 or newer. Revision of motherboard from serial number A6VF021006606 (valid only for Europe). bizhub 4750: Required firmware for blocking: A6F730G0236-999 or newer. Revision of motherboard from serial number A6VF021001836 (valid only for Europe). | No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | bizhub 3602P | No |
No |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A4-BIZHUB-3300P | No |
No |
Recommended driver: MIFALSELTA-PRN-BW-A4-BIZHUB-3300P Limitations: Duplex print is accounted according to parser from job information. There is a 4 seconds timeout after print. | No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 MU28
|
|
Konica Minolta | bizhub 4402P | No |
No |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A4-BIZHUB-3300P | No |
No |
Recommended driver: MIFALSELTA-PRN-BW-A4-BIZHUB-3300P Limitations: Duplex print is accounted according to parser from job information. There is a 4 seconds timeout after print. | No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 MU28
|
|
Konica Minolta | bizhub 4702P | No |
No |
No |
Yes |
No |
MIFALSELTA-PRN-BW-A4-BIZHUB-3300P | No |
No |
Recommended driver: MIFALSELTA-PRN-BW-A4-BIZHUB-3300P Limitations: Duplex print is accounted according to parser from job information. There is a 4 seconds timeout after print. | No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 MU28
|
|
Konica Minolta | bizhub 195 | bizhub | Yes |
Yes |
No |
No |
No |
MIFALSELTA-MFP-BW-A3-DUP-195 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-DUP-195 Limitations: There is a 3 seconds timeout after copy. Counters for copy and print are shared. Only for bizhub 195 with G09-20/G01-03 firmware! | No |
Untested |
No |
No |
No |
No |
No support for Embedded terminal.
|
Konica Minolta | 1250e | bizhub Press | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-BH1052 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-BH1052 Limitations: Duplex print is accounted according to parser from job information. There is a 3 second timeout after print. There is a 3 second timeout after copy. Additional busy state recognition from number of active jobs. This driver is suitable for Mode1 accounting. | No |
Untested |
No |
Yes |
No |
Yes |
Billing code selection and card self-registration is not supported and ends with an error.
|
Konica Minolta | 1052e | bizhub Press | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-BH1052 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-BH1052 Limitations: Duplex print is accounted according to parser from job information. There is a 3 second timeout after print. There is a 3 second timeout after copy. Additional busy state recognition from number of active jobs. This driver is suitable for Mode1 accounting. | No |
Untested |
No |
Yes |
No |
Yes |
Billing code selection and card self-registration is not supported and ends with an error.
|
Konica Minolta | bizhub C3581FS | bizhub | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C3850 | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-BIZHUB-C3850 | Yes |
Yes |
No |
No |
Yes |
Yes |
To use Scan Workflow of SafeQ6 on Native OpenAPI Terminal, use the FW: A92E0Y0-F000-G00-K8 or later.
|
Konica Minolta | bizhub C266 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-C221-M2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-C221-M2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 2 colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) This driver is for "total counter mode 2 MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested Controler ROM version for SafeQ5:
A90G0Y0-8100-G00-03
Authentication cache not yest tested for SafeQ 6.
|
Konica Minolta | bizhub C226 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-C221-M2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-C221-M2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Each 2 colors print is accounted as a full-color print. Each 2 colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mode 2 behavior) This driver is for "total counter mode 2 MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested Controler ROM version for SafeQ5:
A90G0Y0-8100-G00-03
Authentication cache not yest tested for SafeQ 6.
|
Konica Minolta | C350 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-350PCL | No |
No |
Recommended driver:MIFALSELTA-350PCL Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Alternate blocking cable is YSQC0-004-0000 key counter
|
Konica Minolta | C450 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver:MIFALSELTA-BIZC250 Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | C352 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver:MIFALSELTA-BIZC250 Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | C351 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver:MIFALSELTA-BIZC250 Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | C300 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver:MIFALSELTA-BIZC250 Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | C252 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | C250 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver:MIFALSELTA-BIZC250 Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | C25 | bizhub | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C10 | No |
No |
Recommended driver:MIFALSELTA-MFP-COL-BIZHUB-C10 Limitations:KONICA MIFALSELTA magicolor 2590MF is identified as KONICA MIFALSELTA bizhub C10.There is 1 second timeout after copy and print.Device may be after printing/copying too long in BUSY state which causes unwanted delay during printing process (cca. 20 seconds). | No |
Untested |
No |
No |
No |
No |
Features that require MFD Walkup Functions Control are not supported no blocking interface
|
Konica Minolta | C20 | bizhub | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C10 | No |
No |
Recommended driver:MIFALSELTA-MFP-COL-BIZHUB-C10 Limitations:KONICA MIFALSELTA magicolor 2590MF is identified as KONICA MIFALSELTA bizhub C10.There is 1 second timeout after copy and print.Device may be after printing/copying too long in BUSY state which causes unwanted delay during printing process (cca. 20 seconds). | No |
Untested |
No |
No |
No |
No |
Features that require MFD Walkup Functions Control are not supported no blocking interface
|
Konica Minolta | C10 | bizhub | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C10 | No |
No |
Recommended driver:MIFALSELTA-MFP-COL-BIZHUB-C10 Limitations:KONICA MIFALSELTA magicolor 2590MF is identified as KONICA MIFALSELTA bizhub C10.There is 1 second timeout after copy and print.Device may be after printing/copying too long in BUSY state which causes unwanted delay during printing process (cca. 20 seconds). | No |
Untested |
No |
No |
No |
No |
Features that require MFD Walkup Functions Control are not supported no blocking interface
|
Konica Minolta | 470 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-Di470 | No |
No |
Recommended driver:MIFALSELTA-Di470 Limitations: Counters for copy and print are shared. Duplex for printing is detected from job, copy duplex is using duplex counter.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Features that require MFD Walkup Functions Control are not supported
|
|
Konica Minolta | 3510 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-Di | No |
No |
Recommended driver:MIFALSELTA-Di Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Features that require MFD Walkup Functions Control are not supported
|
|
Konica Minolta | 3010 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-Di | No |
No |
Recommended driver:MIFALSELTA-Di Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Features that require MFD Walkup Functions Control are not supported
|
|
Konica Minolta | 2510 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-Di | No |
No |
Recommended driver:MIFALSELTA-Di Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Features that require MFD Walkup Functions Control are not supported
|
|
Konica Minolta | 2050 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-Di2 | No |
No |
Recommended driver:MIFALSELTA-Di2 Limitations:There are 7 seconds timeouts after copy and print.Counters for copy and print are shared.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Features that require MFD Walkup Functions Control are not supported
|
|
Konica Minolta | 2011 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-Di2 | No |
No |
Recommended driver:MIFALSELTA-Di2 Limitations:There are 7 seconds timeouts after copy and print.Counters for copy and print are shared.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Features that require MFD Walkup Functions Control are not supported
|
|
Konica Minolta | 1650 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-Di2 | No |
No |
Recommended driver:MIFALSELTA-Di2 Limitations:There are 7 seconds timeouts after copy and print.Counters for copy and print are shared.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Features that require MFD Walkup Functions Control are not supported
|
|
Konica Minolta | 600 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB Limitations:There are 4.5 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Only Konica Minolta controllers are supported. Online accounting doesnt work with external EFI controllers.
|
|
Konica Minolta | 350 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
Only Konica Minolta controllers are supported. Online accounting does not work with external EFI controllers.
|
|
Konica Minolta | 250 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
Only Konica Minolta controllers are supported. Online accounting does not work with external EFI controllers.
|
|
Konica Minolta | 210 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB-210 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB-210 Limitations: There are 7 seconds timeouts after copy and print. Counters for copy and print are shared. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Only Konica Minolta controllers are supported. Online accounting does not work with external EFI controllers.
|
|
Konica Minolta | 162 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB-210 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB-210 Limitations: There are 7 seconds timeouts after copy and print. Counters for copy and print are shared. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Only Konica Minolta controllers are supported. Online accounting does not work with external EFI controllers.
|
|
Konica Minolta | 43 | bizhub | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A4-BIZHUB-DUP | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-A4-BIZHUB-DUP Limitations:There is 1 second timeout after copy and print.Common duplex counter is used.Counters for print and copy are shared. | No |
Untested |
No |
No |
No |
No |
Features that require MFD Walkup Functions Control are not supported
|
Konica Minolta | 40 | bizhub | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A4-BIZHUB-DUP | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-A4-BIZHUB-DUP Limitations:There is 1 second timeout after copy and print.Common duplex counter is used.Counters for print and copy are shared. | No |
Untested |
No |
No |
No |
No |
Features that require MFD Walkup Functions Control are not supported
|
Konica Minolta | 20 | bizhub | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A4-BIZHUB-V2 | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-A4-BIZHUB-V2 Limitations:There is 1 second timeout after copy and print.Common duplex counter is used.Counters for print and copy are shared. | No |
Untested |
No |
No |
No |
No |
Features that require MFD Walkup Functions Control are not supported
|
Konica Minolta | 7235 | Legacy | Yes |
Yes |
No |
Yes |
Yes |
KONICA | No |
No |
Recommended driver: KONICA Limitations: Enhanced detection of device status There is 5 seconds timeout after print. A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 7222 | Legacy | Yes |
Yes |
No |
Yes |
Yes |
KONICA | No |
No |
Recommended driver:KONICA Limitations:Enhanced detection of device status.There is 5 seconds timeout after print.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 7220 | Legacy | Yes |
Yes |
No |
Yes |
Yes |
KONICA | No |
No |
Recommended driver:KONICA Limitations:Enhanced detection of device status.There is 5 seconds timeout after print.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 7165 | Legacy | Yes |
Yes |
No |
Yes |
Yes |
KONICA | No |
No |
Recommended driver:KONICA Limitations:Enhanced detection of device status.There is 5 seconds timeout after print.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 7155 | Legacy | Yes |
Yes |
No |
Yes |
Yes |
KONICA-7155 | No |
No |
Recommended driver:KONICA-7155 Limitations:Enhanced detection of device status.There is 1 second timeout after print.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 7145 | Legacy | Yes |
Yes |
No |
Yes |
Yes |
KONICA | No |
No |
Recommended driver:KONICA Limitations:Enhanced detection of device status.There is 5 seconds timeout after print.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 7022 | Legacy | Yes |
Yes |
No |
Yes |
Yes |
KONICA | No |
No |
Recommended driver:KONICA Limitations:Enhanced detection of device status.There is 5 seconds timeout after print.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 7020 | Legacy | Yes |
Yes |
No |
Yes |
Yes |
KONICA | No |
No |
Recommended driver:KONICA Limitations:Enhanced detection of device status.There is 5 seconds timeout after print.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | C8000 | bizhub PRO | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-C7000EFI, MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver for IC-306/413:MIFALSELTA-C7000EFI Limitations:Set MFP to increase A4 counter by two for each A3 page (set mode 2 for accounting A3).Status detection is supported for following languages: English. Recommended driver for IC-601:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Print Tracking via online or vendor provided accounting. All features related to hardware terminals are supported.
|
Konica Minolta | C7000 | bizhub PRO | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-C7000EFI, MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver for IC-306/413:MIFALSELTA-C7000EFI Limitations:Set MFP to increase A4 counter by two for each A3 page (set mode 2 for accounting A3).Status detection is supported for following languages: English. Recommended driver for IC-601:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Print Tracking via online or vendor provided accounting. All features related to hardware terminals are supported.
|
Konica Minolta | C6000 | bizhub PRO | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-C7000EFI, MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver for IC-306/413:MIFALSELTA-C7000EFI Limitations:Set MFP to increase A4 counter by two for each A3 page (set mode 2 for accounting A3).Status detection is supported for following languages: English. Recommended driver for IC-601:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Print Tracking via online or vendor provided accounting. All features related to hardware terminals are supported.
|
Konica Minolta | C70hc | bizhub PRO | No |
No |
Yes |
Yes |
No |
MIFALSELTA-PRN-COL-A3-C70HC | No |
No |
Recommended driver:MIFALSELTA-PRN-COL-A3-C70HC Limitations:There is a 1 second timeout after print.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Equipped with Fiery IC-413 (Fiery E100 70-60C-KM)
|
Konica Minolta | 1250 | bizhub Press | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-BH1052 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-BH1052 Limitations: Duplex print is accounted according to parser from job information. There is a 3 second timeout after print. There is a 3 second timeout after copy. Additional busy state recognition from number of active jobs. This driver is suitable for Mode1 accounting. | No |
Untested |
No |
Yes |
No |
Yes |
Billing code selection and card self-registration is not supported and ends with an error.
|
Konica Minolta | 1052 | bizhub Press | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-BH1052 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-BH1052 Limitations: Duplex print is accounted according to parser from job information. There is a 3 second timeout after print. There is a 3 second timeout after copy. Additional busy state recognition from number of active jobs. This driver is suitable for Mode1 accounting. | No |
Untested |
No |
Yes |
No |
Yes |
Billing code selection and card self-registration is not supported and ends with an error.
|
Konica Minolta | 1200P | bizhub PRO | No |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB-1200P | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB-1200P Limitations:This driver is suitable for Mode2 accounting.There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Print Tracking via online or vendor provided accounting. All features related to hardware terminals are supported. Limitations: Set MFP to increase A4 counter by two for each A3 page (set mode 2 for accounting A3).To prevent long time-outs between print jobs, set "cntrMaxDiff = 10000" in SafeQ configuration.
|
Konica Minolta | 951 | bizhub PRO | No |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB Limitations:There are 4.5 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs. In SafeQ Terminal configuration "Copier locking" option should be set to "From server" to avoid paper jams in specific scenarios. Blocking interface:PRO951 does FALSEt support the key counter formally.Please contact Konica MiFALSElta for more information. | No |
Untested |
No |
No |
No |
No |
Print Tracking via online or vendor provided accounting. All features related to hardware terminals are supported. To prevent long time-outs between print jobs, set "cntrMaxDiff = 10000" in SafeQ configuration.
|
Konica Minolta | 1200 | bizhub PRO | No |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB Limitations:There are 4.5 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs. In SafeQ Terminal configuration "Copier locking" option should be set to "From server" to avoid paper jams in specific scenarios. | No |
Untested |
No |
No |
No |
No |
Print Tracking via online or vendor provided accounting. All features related to hardware terminals are supported. To prevent long time-outs between print jobs, set "cntrMaxDiff = 10000" in SafeQ configuration.
|
Konica Minolta | 1051 | bizhub PRO | No |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB Limitations:There are 4.5 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs. In SafeQ Terminal configuration "Copier locking" option should be set to "From server" to avoid paper jams in specific scenarios. | No |
Untested |
No |
No |
No |
No |
Print Tracking via online or vendor provided accounting. All features related to hardware terminals are supported. To prevent long time-outs between print jobs, set "cntrMaxDiff = 10000" in SafeQ configuration.
|
Konica Minolta | 1050 | bizhub PRO | No |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB Limitations:There are 4.5 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs. In SafeQ Terminal configuration "Copier locking" option should be set to "From server" to avoid paper jams in specific scenarios. | No |
Untested |
No |
No |
No |
No |
Print Tracking via online or vendor provided accounting. All features related to hardware terminals are supported. To prevent long time-outs between print jobs, set "cntrMaxDiff = 10000" in SafeQ configuration.
|
Konica Minolta | 950 | bizhub PRO | No |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB Limitations:There are 4.5 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs. In SafeQ Terminal configuration "Copier locking" option should be set to "From server" to avoid paper jams in specific scenarios. | No |
Untested |
No |
No |
No |
No |
Print Tracking via online or vendor provided accounting. All features related to hardware terminals are supported. To prevent long time-outs between print jobs, set "cntrMaxDiff = 10000" in SafeQ configuration.
|
Konica Minolta | 920 | bizhub PRO | No |
No |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB Limitations:There are 4.5 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs. In SafeQ Terminal configuration "Copier locking" option should be set to "From server" to avoid paper jams in specific scenarios. | No |
Untested |
No |
No |
No |
No |
Print Tracking via online or vendor provided accounting. All features related to hardware terminals are supported. To prevent long time-outs between print jobs, set "cntrMaxDiff = 10000" in SafeQ configuration.
|
Konica Minolta | C35p | bizhub | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-DUP-A4-C35P | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | C30p | bizhub | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-A4-C30P | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | C25p | bizhub | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-A4-C30P | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | C20p | bizhub | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-A4-C30P | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 40p | bizhub | No |
No |
No |
Yes |
Yes |
MIFALSELTA-PRN-BW-5650 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 20p | bizhub | No |
No |
No |
Yes |
Yes |
MIFALSELTA-PRN-BW-A4-DUP-BIZHUB | No |
No |
Recommended driver:MIFALSELTA-PRN-BW-A4-DUP-BIZHUB Limitations:There is 1 second timeout after print. Duplex is detected from job. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 8650 | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-A4-8650 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 5440 | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-5440 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 4650 | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-A4-4650 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 2590MF | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-BIZHUB-C10 | No |
No |
Recommended driver:MIFALSELTA-MFP-COL-BIZHUB-C10 Limitations:KONICA MIFALSELTA magicolor 2590MF is identified as KONICA MIFALSELTA bizhub C10.There is 1 second timeout after copy and print.Device may be after printing/copying too long in BUSY state which causes unwanted delay during printing process (cca. 20 seconds). | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 5670 | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-5450-DUP | No |
No |
Recommended driver:MIFALSELTA-PRN-COL-5450-DUP Limitations:Additional busy state recognition from number of active jobs.Driver uses common duplex counter. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 5650 | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-5450-DUP | No |
No |
Recommended driver:MIFALSELTA-PRN-COL-5450-DUP Limitations:Additional busy state recognition from number of active jobs.Driver uses common duplex counter. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 5550 | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-5450-DUP | No |
No |
Recommended driver:MIFALSELTA-PRN-COL-5450-DUP Limitations:Additional busy state recognition from number of active jobs.Driver uses common duplex counter. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 5450 | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-5450-DUP | No |
No |
Recommended driver:MIFALSELTA-PRN-COL-5450-DUP Limitations:Additional busy state recognition from number of active jobs.Driver uses common duplex counter. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 2550 | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-5450-DUP | No |
No |
Recommended driver:MIFALSELTA-PRN-COL-5450-DUP Limitations:Additional busy state recognition from number of active jobs.Driver uses common duplex counter. | No |
Untested |
No |
No |
No |
No |
|
Konica Minolta | 2450 | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-PRN-COL-2450 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 7300 | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MCol | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 3100 | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MCol | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 2300DL | Magicolor | No |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MCol | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 9100 | PagePro | No |
No |
No |
Yes |
Yes |
MIFALSELTA-PP-PRN | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 5650 | PagePro | No |
No |
No |
Yes |
Yes |
MIFALSELTA-PRN-BW-5650 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 4650 | PagePro | No |
No |
No |
Yes |
Yes |
MIFALSELTA-PRN-BW-5650 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 1350EN | PagePro | No |
Yes |
No |
Yes |
Yes |
MIFALSELTA-PRN-BW-1350 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | Di650 (Fiery X3e 65BW-M) | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-DiF | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | Di551 (Fiery X3e 65BW-M) | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-DiF | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | CF3102 (Fiery X3e 31C-M) | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-FIERY | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | CF2002 (Fiery X3e 31C-M) | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-FIERY | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Konica Minolta | C652DS | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
Scan Color auto detection not supported with Browser Embedded terminal.
|
|
Konica Minolta | C552DS | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
Scan Color auto detection not supported with Browser Embedded terminal.
|
|
Konica Minolta | C652 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
Scan Color auto detection not supported with Browser Embedded terminal.
|
Konica Minolta | bizhub C552 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
Scan Color auto detection not supported with Browser Embedded terminal.
|
|
Konica Minolta | bizhub C452 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
Scan Color auto detection not supported with Browser Embedded terminal.
|
|
Konica Minolta | bizhub C650 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver:MIFALSELTA-BIZC250 Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 1,5GB (extended memory UK-201) Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 1,5GB (extended memory UK-201), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Konica Minolta | bizhub C550 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver:MIFALSELTA-BIZC250 Limitations:There are 3 seconds timeouts after copy and print.Duplex for printing is detected from job.Duplex copy is using duplex counter.Additional busy state recognition from number of active jobs.A device must be set to mode 2. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 1,5GB (extended memory UK-201) Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 1,5GB (extended memory UK-201), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Konica Minolta | bizhub C542 | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported. It is possible to use Key-counter cable, however you will not be able to block first page of color copy.
|
|||
Konica Minolta | C451 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC451 | No |
Yes |
Recommended driver:MIFALSELTA-BIZC451 Limitations:There are 10 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs.A device must be set to mode 2. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 1,5GB (extended memory UK-201) Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 1,5GB (extended memory UK-201), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
Konica Minolta | 367 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Recommended latest firmware (above G00-24).
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
Konica Minolta | bizhub 287 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Recommended latest firmware (above G00-24).
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
|
Konica Minolta | 227 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Recommended latest firmware (above G00-24).
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
Konica Minolta | C287 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Tested FW: A7970Y0-0100-G00-10(00) Supports SafeQ 6 Basic and Advanced Finishing Options. SafeQ 6 Universal Print Driver compatible.
|
Konica Minolta | C227 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Tested FW: A7970Y0-0100-G00-10(00) Supports SafeQ 6 Basic and Advanced Finishing Options. SafeQ 6 Universal Print Driver compatible.
|
Konica Minolta | bizhub 754e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. When blocked with Vender2 cable, online accounting does FALSEt work, machine is FALSEt increasing counters. This problem can be solved by using firmware version GD1-83 | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | 654e | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. When blocked with Vender2 cable, online accounting does FALSEt work, machine is FALSEt increasing counters. This problem can be solved by using firmware version GD1-83 | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
Duplex scan workflow not supported with Native Embedded terminal.
|
Konica Minolta | bizhub 554e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | bizhub 454e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | bizhub 364e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | 284e | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
Duplex scan workflow not supported with Native Embedded terminal.
|
Konica Minolta | bizhub 224e | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. A device must be set to mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | C368 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
Yes |
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
(SafeQ6 GEN2) Authentication cache not supported.
(SafeQ5 GEN1/SafeQ6 GEN2) Attempting to scan to “JPEG in BW” using SafeQ Scan Workflow does not start scanning because it is unsupported combination by bizhub.
|
Konica Minolta | C308 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
Konica Minolta | C258 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | Yes |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
Konica Minolta | bizhub PRO C754e (EFI Fiery IC-414) | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-C754E-FIERY | No |
Yes |
Recommended driver for SafeQ 3.6:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:For Fiery use data delivery IP.There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy.A device must be set to mode 2. Recommended driver for SafeQ 4/5:MIFALSELTA-MFP-COL-A3-C754E-FIERY Limitations:There is a 26 seconds timeout after print.Duplex print is detected from print job parser.A device must be set to mode 2. Status detection during copy/scan is FALSEt supported.For proper copy accounting use Offline copy accounting (via blocking cable) on device with Fiery IP and create either: Second device with MFD IP, offline print accounting (Device settings: Advanced settings in SafeQ 5 / Device settings: Price list settings in SafeQ 4) and online accounting driver MIFALSELTA-MFP-COL-A3-CXXXE-V2 OR Second device with MFD IP, offline print accounting and install Embedded Terminal | Yes |
Yes |
No |
No |
Yes |
No |
Duplex scan workflow not supported with Native Embedded terminal.
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-83
|
|
Konica Minolta | bizhub C754e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | bizhub C654e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | bizhub C554e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
OpenApi version 3.7.2 supported so far.
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Konica Minolta | bizhub C454e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | bizhub C364e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | bizhub C284e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | C224e | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Browser with/without MyPanel:
HDD: 250GB Memory: 4GB (extended memory UK-204)
LK-101v3 iOption License Kit (LK-101)
When blocked with Vender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
Duplex scan workflow not supported with Native Embedded terminal.
|
Konica Minolta | bizhub C754 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB and Memory: 2GB built in by default
Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204)
Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58).
USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Card registration and billing code selection in the same authentication causes the terminal to stay in main authentication screen.
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | bizhub C654 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB and Memory: 2GB built in by default
Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204)
Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58).
USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Card registration and billing code selection in the same authentication causes the terminal to stay in main authentication screen.
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | bizhub C554 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB and Memory: 2GB built in by default
Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204)
Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58).
USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Card registration and billing code selection in the same authentication causes the terminal to stay in main authentication screen.
|
|
Konica Minolta | C454 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB and Memory: 2GB built in by default
Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204)
Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58).
USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Card registration and billing code selection in the same authentication causes the terminal to stay in main authentication screen.
Duplex scan workflow not supported with Native Embedded terminal.
|
Konica Minolta | bizhub C364 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB and Memory: 2GB built in by default
Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204)
Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58).
USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Card registration and billing code selection in the same authentication causes the terminal to stay in main authentication screen.
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | bizhub C284 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB and Memory: 2GB built in by default
Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204)
Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58).
USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Card registration and billing code selection in the same authentication causes the terminal to stay in main authentication screen.
Duplex scan workflow not supported with Native Embedded terminal.
|
|
Konica Minolta | C224 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
Yes |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB and Memory: 2GB built in by default
Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204)
Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58).
USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
Card registration and billing code selection in the same authentication causes the terminal to stay in main authentication screen.
Duplex scan workflow not supported with Native Embedded terminal.
|
Konica Minolta | C360 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
Yes |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
HDD: 250GB, Memory: 2GB
Native with MyPanel:
DD: 250GB Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel:
HDD: 250GB Memory: 3GB (extended memory UK-203) LK-101v2 iOption License Kit
Recommended latest FW for embedded terminal.
|
Konica Minolta | C280 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
Yes |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
HDD: 250GB, Memory: 2GB
Native with MyPanel:
DD: 250GB Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel:
HDD: 250GB Memory: 3GB (extended memory UK-203) LK-101v2 iOption License Kit
Recommended latest FW for embedded terminal.
|
Konica Minolta | C220 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
Yes |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native:
HDD: 250GB, Memory: 2GB
Native with MyPanel:
DD: 250GB Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel:
HDD: 250GB Memory: 3GB (extended memory UK-203) LK-101v2 iOption License Kit
Recommended latest FW for embedded terminal.
|
Konica Minolta | bizhub C200 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver:MIFALSELTA-BIZC250 Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported. It is possible to use Key-counter cable, however you will not be able to block first page of color copy.
|
|
Konica Minolta | bizhub C353 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting Native with MyPanel: HDD: 250GB (HDD HD-516) Memory:1,5GB extended memory UK-201
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory:1,5GB extended memory UK-201, LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Konica Minolta | bizhub C253 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
No |
Recommended driver: MIFALSELTA-BIZC250 Limitations: There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting Native with MyPanel: HDD: 250GB (HDD HD-516) Memory:1,5GB extended memory UK-201
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory:1,5GB extended memory UK-201, LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Konica Minolta | C203 | bizhub | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-BIZC250 | No |
Yes |
Recommended driver:MIFALSELTA-BIZC250 Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. A device must be set to mode 2. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting Native with MyPanel: HDD: 250GB (HDD HD-516) Memory:1,5GB extended memory UK-201 Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory:1,5GB extended memory UK-201, LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
Konica Minolta | bizhub C35 | Yes |
No |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A4-DUP-BIZHUB-C35 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A4-DUP-BIZHUB-C35 Limitations: There is 1 second timeout after copy and print. Additional busy state recognition from number of active jobs. Device has FALSE interface for external blocking cable - blocking possible only with embedded terminal Firmware version A121-30G0-0649-05 (Special ROM, OpenAPI 2.3 - 3.5). Duplex tracking is FALSEt supported. It is FALSEt possible to use Key-counter cable. | Yes |
Yes |
No |
No |
Yes |
No |
Recommended latest FW for embedded terminal.
Logout before all jobs are printed causes that only the first job is accounted.
Swipe with card immediately when authentication screen is displayed causes that user is not logged in.
After successful card self-registration, the billing code selection screen causes an error.
Users have to authenticate again after the card self-registration.
|
|
Konica Minolta | bizhub 36 | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-PRN-BW-42 | No |
No |
Recommended driver:MIFALSELTA-PRN-BW-42 Limitations:Simplex/duplex A4 print/copy is supported. Simplex/duplex A3 print is supported. | Yes |
Yes |
No |
No |
Yes |
No |
Blocking not supported.
|
|
Konica Minolta | bizhub 42 | Yes |
No |
No |
Yes |
Yes |
MIFALSELTA-PRN-BW-42 | No |
No |
Recommended driver:MIFALSELTA-PRN-BW-42 Limitations:Simplex/duplex A4 print/copy is supported. Simplex/duplex A3 print is supported. | Yes |
Yes |
No |
No |
Yes |
No |
Blocking not supported.
|
|
Konica Minolta | bizhub 754 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
||
Konica Minolta | 654 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-XXXE, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-A3-XXXE Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
|
Konica Minolta | bizhub 801 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB Limitations:There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 1,5GB (extended memory UK-201) Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 1,5GB (extended memory UK-201), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
|
Konica Minolta | 751 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
Yes |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB Limitations:There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 1,5GB (extended memory UK-201) Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 1,5GB (extended memory UK-201), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
Konica Minolta | 601 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
Yes |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB Limitations:There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 1,5GB (extended memory UK-201) Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 1,5GB (extended memory UK-201), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
Konica Minolta | 501 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
Yes |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | Yes |
Yes |
No |
No |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 1,5GB (extended memory UK-201) Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 1,5GB (extended memory UK-201), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
Konica Minolta | 421 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 1,5GB (extended memory UK-201) Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 1,5GB (extended memory UK-201), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
Konica Minolta | 361 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
Yes |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB Limitations:There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | Yes |
Yes |
No |
No |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 1,5GB for Account Maps accounting Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 1,5GB (extended memory UK-201) Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 1,5GB (extended memory UK-201), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
Konica Minolta | bizhub 500 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | bizhub 420 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | bizhub 360 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB Limitations:There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
||
Konica Minolta | 423 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2 Limitations: There are 3 seconds timeouts after copy and print. Additional busy state recognition from number of active jobs. This driver is suitable for Mode2 accounting. Offline copy accounting enabled. A3 scan is accounted as 2xA4. Each scan is accounted also as a copy with 0 pages. Separate counters for print and copy. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
Konica Minolta | 363 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2 Limitations: There are 3 seconds timeouts after copy and print. Additional busy state recognition from number of active jobs. This driver is suitable for Mode2 accounting. Offline copy accounting enabled. A3 scan is accounted as 2xA4. Each scan is accounted also as a copy with 0 pages. Separate counters for print and copy. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
Konica Minolta | 283 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
Yes |
Recommended driver: MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2 Limitations: There are 3 seconds timeouts after copy and print. Additional busy state recognition from number of active jobs. This driver is suitable for Mode2 accounting. Offline copy accounting enabled. A3 scan is accounted as 2xA4. Each scan is accounted also as a copy with 0 pages. Separate counters for print and copy. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
Konica Minolta | 223 | bizhub | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2, MIFALSELTA-MFP-BW-A3-XXXE-V3, MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 | No |
No |
Recommended driver: MIFALSELTA-MFP-A3-DUP-SCAN-BIZHUB-363-V2 Limitations: There are 3 seconds timeouts after copy and print. Additional busy state recognition from number of active jobs. This driver is suitable for Mode2 accounting. Offline copy accounting enabled. A3 scan is accounted as 2xA4. Each scan is accounted also as a copy with 0 pages. Separate counters for print and copy. MIFALSELTA-MFP-BW-A3-XXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. A device must be set to total counter mode 2. MIFALSELTA-MFP-BW-A3-XXXE-V3-M1 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
Native: HDD: 250GB (HDD HD-516), Memory: 2GB
Native with MyPanel: HDD: 250GB (HDD HD-516) Memory: 3GB (extended memory UK-203)
Browser with/without MyPanel: HDD: 250GB (HDD-HD-516), Memory: 3GB (extended memory UK-203), LK-101 iOption License Kit Recommended latest FW for embedded terminal.
|
Konica Minolta | bizhub 306 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 Limitations:There are 3 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Konica Minolta | bizhub 266 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 Limitations: There is 3 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Konica Minolta | bizhub 246 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 Limitations:There are 3 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Konica Minolta | bizhub 226 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 Limitations: There is 3 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Konica Minolta | bizhub 206 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 Limitations: There are 3 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Konica Minolta | bizhub 215 | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-DUP-BIZHUB-215 Limitations: There are 3 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Konica Minolta | bizhub 362 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Konica Minolta | bizhub 282 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-BIZHUB Limitations: There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Konica Minolta | bizhub 222 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-BIZHUB | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-BIZHUB Limitations:There are 4.5 seconds timeouts after copy and print. Duplex for printing is detected from job. Duplex copy is using duplex counter. Additional busy state recognition from number of active jobs. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Konica Minolta | bizhub 211 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-211 | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-A3-211 Limitations:There is a 2 seconds timeout after print.There is a 2 seconds timeout after copy.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Konica Minolta | bizhub 163 | Yes |
Yes |
No |
Yes |
Yes |
MIFALSELTA-MFP-BW-A3-211 | No |
No |
Recommended driver: MIFALSELTA-MFP-BW-A3-211 Limitations: There is a 2 seconds timeout after print. There is a 2 seconds timeout after copy. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
|
Kyocera | TASKalfa 508ci | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera | TASKalfa 408ci | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera | TASKalfa 4054ci | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera | TASKalfa 8003i | Yes |
Yes |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera | TASKalfa 8353ci | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera | TASKalfa 5054ci | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera | TASKalfa 6054ci | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera | TASKalfa 7003i | Yes |
Yes |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera | TASKalfa 7054ci | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera | TASKalfa 7353ci | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera | TASKalfa 9003i | Yes |
Yes |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera | ECOSYS M3860idnf | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
Add req. hardware require an external memory card (CF or SD Card according to the device specifications)
|
|||
Kyocera | ECOSYS M6630cidn | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
Add req. hardware require an external memory card (CF or SD Card according to the device specifications)
|
|||
Kyocera | ECOSYS M3860idnf | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera | ECOSYS MA5500ifx | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera | ECOSYS MA6000ifx | Yes |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
Yes |
No |
No |
||||
Kyocera Mita | TASKalfa 550c | Broad Peak | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | TASKalfa 265ci | Black Gemini | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | TASKalfa 820 | Harrier 1.5 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | TASKalfa 620 | Harrier 1.5 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | TASKalfa 180 | Orion GDI | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | KM-5530 | Eagle | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | KM-4530 | Eagle | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | KM-7530 | Pegasus 3 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | KM-6330 | Pegasus 2 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | KM-6230 | Pegasus 1 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | KM-1635 | Atlantis GDI | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | KM-1620 | Atlantis Copier | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | TASKalfa 306i | Matsuri HyPAS | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | TASKalfa 256i | Matsuri HyPAS | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-6530MFP | Matsuri HyPAS | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-6525MFP | Matsuri HyPAS | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | ECOSYS M6530cdn | Yes |
No |
Yes |
Yes |
No |
KM-KYO-MFP-COL-A4-2526 | No |
No |
Recommended driver:KM-KYO-MFP-COL-A4-2526 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | ECOSYS M2535dn | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver:KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | ECOSYS M2035dn | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver:KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | TASKalfa 2550ci | Jupiter | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051CI | No |
No |
Recommended driver:KM-MFP-COL-A3-TA3051CI Limitations:Each A3 page is accounted as two A4 pages.MoFALSEcolor copy counter starts from 1.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-3640MFP | Cygnus H | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver:KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information. Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-3540MFP | Cygnus H | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver:KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information. Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-3040MFP | Cygnus H | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver:KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 5551ci | Venus 2 | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051CI | No |
No |
Recommended driver: KM-MFP-COL-A3-TA3051CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 4551ci | Venus 2 | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051CI | No |
No |
Recommended driver: KM-MFP-COL-A3-TA3051CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 3551ci | Venus 2 | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051CI | No |
No |
Recommended driver: KM-MFP-COL-A3-TA3051CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 3051ci | Venus 2 | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051CI | No |
No |
Recommended driver: KM-MFP-COL-A3-TA3051CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 300i | Stratos 2 | Yes |
Yes |
No |
Yes |
Yes |
KM-MFP-BW-A3-300i | No |
No |
Recommended driver:KM-MFP-BW-A3-300i Limitations:Duplex pages are accounted as simplex. The same counters for print and copy. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-C8025 | Hanabi | Yes |
Yes |
Yes |
Yes |
No |
KM-FS-COL-MFP-A3-C8020 | No |
No |
Recommended driver:KM-FS-COL-MFP-A3-C8020 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Each A3 page is accounted as two A4 pages. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-C8020 | Hanabi | Yes |
Yes |
Yes |
Yes |
No |
KM-FS-COL-MFP-A3-C8020 | No |
No |
Recommended driver:KM-FS-COL-MFP-A3-C8020 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Each A3 page is accounted as two A4 pages. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-C8100DN+ | Voyager Printer | No |
Yes |
Yes |
Yes |
No |
KM-PRN-COL-A3 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-C8100DN | Voyager Printer | No |
Yes |
Yes |
Yes |
No |
KM-PRN-COL-A3 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-C5025N | No |
No |
Yes |
Yes |
No |
KM-COL-PRN | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C5016N | No |
No |
Yes |
Yes |
No |
KM-COL-PRN | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C5015N | No |
No |
Yes |
Yes |
No |
KM-COL-PRN | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-9530DN | Hornet 3 | No |
Yes |
No |
Yes |
No |
KM-RFC-PRN | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-9130DN | Hornet 3 | No |
Yes |
No |
Yes |
No |
KM-RFC-PRN | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-9000 | No |
No |
No |
Yes |
No |
KM-RFC-PRN | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-6700 | No |
No |
No |
Yes |
No |
KM-KYO-PRN | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-3900DN | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS3920DN-V2 | No |
No |
Recommended driver:KM-PRN-BW-A4-FS3920DN-V2 Limitations:Status detection is supported for following languages: English, Hungarian.Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-1116MFP | Dragon | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver: KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1135MFP | Discovery 35 | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver: KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1035MFP | Discovery 35 | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver: KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1130MFP | Discovery 30 | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver: KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1030MFP | Discovery 30 | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver: KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-3140MFP+ | Cygnus L | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver:KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-3040MFP+ | Cygnus L | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver:KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-3140MFP | Cygnus MFP | Yes |
No |
No |
Yes |
No |
KM-KYO-MFP-BW-A4-3140-V2 | No |
No |
Recommended driver:KM-KYO-MFP-BW-A4-3140-V2 Limitations:Duplex is detected from job. Duplex copies are accounted as simplex. There are 3 seconds timeouts after copy and print. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-3040MFP | Cygnus MFP | Yes |
No |
No |
Yes |
No |
KM-KYO-MFP-BW-A4-3140-V2 | No |
No |
Recommended driver:KM-KYO-MFP-BW-A4-3140-V2 Limitations:Duplex is detected from job. Duplex copies are accounted as simplex. There are 3 seconds timeouts after copy and print. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-C2626MFP | Gemini H | Yes |
No |
Yes |
Yes |
No |
KM-KYO-MFP-COL-A4-2526 | No |
No |
Recommended driver:KM-KYO-MFP-COL-A4-2526 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-C2526MFP | Gemini H | Yes |
No |
Yes |
Yes |
No |
KM-KYO-MFP-COL-A4-2526 | No |
No |
Recommended driver:KM-KYO-MFP-COL-A4-2526 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-C2126MFP | Gemini MFP | Yes |
No |
Yes |
Yes |
No |
KM-KYO-MFP-COL-A4-2126 | No |
No |
Recommended driver:KM-KYO-MFP-COL-A4-2126 Limitations:Driver accounts A4 black-and-white duplex print job as A4 black-and-white simplex print job. Driver accounts A4 color duplex print job as A4 black-and-white simplex print job. Driver accounts A4 black-and-white duplex copy job as two A4 black-and-white simplex print jobs. Driver accounts A4 color duplex print job as two A4 black-and-white simplex print job. English and Hungarian languages are supported for MFP status. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-C2026MFP | Gemini MFP | Yes |
No |
Yes |
Yes |
No |
KM-KYO-MFP-COL-A4-2126 | No |
No |
Recommended driver:KM-KYO-MFP-COL-A4-2126 Limitations:Driver accounts A4 black-and-white duplex print job as A4 black-and-white simplex print job. Driver accounts A4 color duplex print job as A4 black-and-white simplex print job. Driver accounts A4 black-and-white duplex copy job as two A4 black-and-white simplex print jobs. Driver accounts A4 color duplex print job as two A4 black-and-white simplex print job. English and Hungarian languages are supported for MFP status. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-4020DN | 5th Generation + | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS3920DN-V2 | No |
No |
Recommended driver:KM-PRN-BW-A4-FS3920DN-V2 Limitations:Status detection is supported for following languages: English, Hungarian.Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-3920DN | 5th Generation + | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS3920DN-V2 | No |
No |
Recommended driver:KM-PRN-BW-A4-FS3920DN-V2 Limitations:Status detection is supported for following languages: English, Hungarian.Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-2020D | 5th Generation + | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS3920DN-V2 | No |
No |
Recommended driver:KM-PRN-BW-A4-FS3920DN-V2 Limitations:Status detection is supported for following languages: English, Hungarian.Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1128MFP | Discovery 2 | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver:KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1028MFP | Discovery 2 | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver:KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1370DN | Dolphin Net + | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS1120D | No |
No |
Recommended driver:KM-PRN-BW-A4-FS1120D Limitations:There is a 2 seconds timeout after print. Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1350DN | Dolphin Net | No |
No |
No |
Yes |
No |
KM-RFC-PRN-V2 | No |
No |
Recommended driver:KM-RFC-PRN-V2 Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1320D | Dolphin + | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS1120D | No |
No |
Recommended driver:KM-PRN-BW-A4-FS1120D Limitations:There is a 2 seconds timeout after print. Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1120D | Dolphin + | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS1120D | No |
No |
Recommended driver:KM-PRN-BW-A4-FS1120D Limitations:There is a 2 seconds timeout after print. Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1118MFP | Yes |
No |
No |
Yes |
No |
KM-MFP-BW-A4 | No |
No |
Recommended driver:KM-MFP-BW-A4 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-1300D | Dolphin | No |
No |
No |
Yes |
No |
KM-RFC-PRN | No |
No |
Recommended driver:KM-RFC-PRN Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1100 | Dolphin | No |
No |
No |
Yes |
No |
KM-RFC-PRN | No |
No |
Recommended driver:KM-RFC-PRN Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1030D | No |
No |
No |
Yes |
No |
KM-RFC-PRN | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | TASKalfa 2551ci | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051CI | No |
No |
Recommended driver: KM-MFP-COL-A3-TA3051CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | TASKalfa 5550ci | Venus | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3050CI | No |
No |
Recommended driver: KM-MFP-COL-A3-TA3050CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 4550ci | Venus | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3050CI | No |
No |
Recommended driver: KM-MFP-COL-A3-TA3050CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 3550ci | Venus | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3050CI | No |
No |
Recommended driver: KM-MFP-COL-A3-TA3050CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 3050ci | Venus | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3050CI | No |
No |
Recommended driver: KM-MFP-COL-A3-TA3050CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 3510i | Yes |
Yes |
No |
Yes |
Yes |
KM-MFP-BW-A3-TA3501I | No |
No |
Recommended driver:KM-MFP-BW-A3-TA3501I Limitations:Each A3 page is accounted as 2xA4 pages.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | TASKalfa 3010i | Yes |
Yes |
No |
Yes |
Yes |
KM-MFP-BW-A3-TA3501I | No |
No |
Recommended driver:KM-MFP-BW-A3-TA3501I Limitations:Each A3 page is accounted as 2xA4 pages.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | TASKalfa 5501i | Gaia 2 | Yes |
Yes |
No |
Yes |
Yes |
KM-MFP-BW-A3-TA3501I | No |
No |
Recommended driver:KM-MFP-BW-A3-TA3501I Limitations:Each A3 page is accounted as 2xA4 pages.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 4501i | Gaia 2 | Yes |
Yes |
No |
Yes |
Yes |
KM-MFP-BW-A3-TA3501I | No |
No |
Recommended driver:KM-MFP-BW-A3-TA3501I Limitations:Each A3 page is accounted as 2xA4 pages.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 3501i | Gaia 2 | Yes |
Yes |
No |
Yes |
Yes |
KM-MFP-BW-A3-TA3501I | No |
No |
Recommended driver:KM-MFP-BW-A3-TA3501I Limitations:Each A3 page is accounted as 2xA4 pages.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 5500i | Gaia | Yes |
Yes |
No |
Yes |
Yes |
KM-MFP-BW-A3-TA3501I | No |
No |
Recommended driver:KM-MFP-BW-A3-TA3501I Limitations:Each A3 page is accounted as 2xA4 pages.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 4500i | Gaia | Yes |
Yes |
No |
Yes |
Yes |
KM-MFP-BW-A3-TA3501I | No |
No |
Recommended driver:KM-MFP-BW-A3-TA3501I Limitations:Each A3 page is accounted as 2xA4 pages.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 3500i | Gaia | Yes |
Yes |
No |
Yes |
Yes |
KM-MFP-BW-A3-TA3501I | No |
No |
Recommended driver:KM-MFP-BW-A3-TA3501I Limitations:Each A3 page is accounted as 2xA4 pages.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 520i | Falcon 4 | Yes |
Yes |
No |
Yes |
Yes |
KM-MFP-BW-A3-420i-adv | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | TASKalfa 420i | Falcon 4 | Yes |
Yes |
No |
Yes |
Yes |
KM-MFP-BW-A3-420i-adv | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-C8525MFP | Hanabi HyPAS | Yes |
Yes |
Yes |
Yes |
No |
KM-FS-COL-MFP-A3-C8020 | No |
No |
Recommended driver:KM-FS-COL-MFP-A3-C8020 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Each A3 page is accounted as two A4 pages. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-C8520MFP | Hanabi HyPAS | Yes |
Yes |
Yes |
Yes |
No |
KM-FS-COL-MFP-A3-C8020 | No |
No |
Recommended driver:KM-FS-COL-MFP-A3-C8020 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Each A3 page is accounted as two A4 pages. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 256ci | Hanabi HyPAS | Yes |
Yes |
Yes |
Yes |
No |
KM-FS-COL-MFP-A3-C8020 | No |
No |
Recommended driver:KM-FS-COL-MFP-A3-C8020 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Each A3 page is accounted as two A4 pages. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 206ci | Hanabi HyPAS | Yes |
Yes |
Yes |
Yes |
No |
KM-FS-COL-MFP-A3-C8020 | No |
No |
Recommended driver:KM-FS-COL-MFP-A3-C8020 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Each A3 page is accounted as two A4 pages. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 552ci | Saturn | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051CI | No |
No |
Recommended driver:KM-MFP-COL-A3-TA3051CI Limitations:Each A3 page is accounted as two A4 pages.MoFALSEcolor copy counter starts from 1.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 500ci | Saturn | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051CI | No |
No |
Recommended driver:KM-MFP-COL-A3-TA3051CI Limitations:Each A3 page is accounted as two A4 pages.MoFALSEcolor copy counter starts from 1.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 400ci | Saturn | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051CI | No |
No |
Recommended driver:KM-MFP-COL-A3-TA3051CI Limitations:Each A3 page is accounted as two A4 pages.MoFALSEcolor copy counter starts from 1.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 300ci | Saturn | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051CI | No |
No |
Recommended driver:KM-MFP-COL-A3-TA3051CI Limitations:Each A3 page is accounted as two A4 pages.MoFALSEcolor copy counter starts from 1.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 250ci | Saturn | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051CI | No |
No |
Recommended driver:KM-MFP-COL-A3-TA3051CI Limitations:Each A3 page is accounted as two A4 pages.MoFALSEcolor copy counter starts from 1.Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-C4035E | Voyager 1.5 | Yes |
Yes |
Yes |
Yes |
Yes |
KM-COL-MFP2 | No |
No |
Recommended driver:KM-COL-MFP2 Limitations:There is 2 seconds timeout after print and copy. Driver accounts a A4 duplex print/copy job as two simplex print/copy jobs. Driver accounts a A3 print/copy job as two A4 print/copy jobs. Driver accounts a A3 duplex print/copy job as four A4 simplex print/copy jobs. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-C3232E | Voyager 1.5 | Yes |
Yes |
Yes |
Yes |
Yes |
KM-COL-MFP2 | No |
No |
Recommended driver:KM-COL-MFP2 Limitations:There is 2 seconds timeout after print and copy. Driver accounts a A4 duplex print/copy job as two simplex print/copy jobs. Driver accounts a A3 print/copy job as two A4 print/copy jobs. Driver accounts a A3 duplex print/copy job as four A4 simplex print/copy jobs. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-C2525E | Voyager 1.5 | Yes |
Yes |
Yes |
Yes |
Yes |
KM-COL-MFP2 | No |
No |
Recommended driver:KM-COL-MFP2 Limitations:There is 2 seconds timeout after print and copy. Driver accounts a A4 duplex print/copy job as two simplex print/copy jobs. Driver accounts a A3 print/copy job as two A4 print/copy jobs. Driver accounts a A3 duplex print/copy job as four A4 simplex print/copy jobs. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-C3232 | Voyager 1.0 | Yes |
Yes |
Yes |
Yes |
Yes |
KM-COL-MFP | No |
No |
Recommended driver:KM-COL-MFP Limitations:If reading of moFALSEcolor counters failed, try to use driver for same devices without moFALSEcolor. This driver supports moFALSEcolor accounting. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-C3225 | Voyager 1.0 | Yes |
Yes |
Yes |
Yes |
Yes |
KM-COL-MFP | No |
No |
Recommended driver:KM-COL-MFP Limitations:If reading of moFALSEcolor counters failed, try to use driver for same devices without moFALSEcolor. This driver supports moFALSEcolor accounting. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-C2520 | Voyager 1.0 | Yes |
Yes |
Yes |
Yes |
Yes |
KM-COL-MFP | No |
No |
Recommended driver:KM-COL-MFP Limitations:If reading of moFALSEcolor counters failed, try to use driver for same devices without moFALSEcolor. This driver supports moFALSEcolor accounting. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | 8030 | Harrier | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP2 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | KM-6030 | Harrier | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP2 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | TASKalfa 221 | Orion | Yes |
Yes |
No |
Yes |
No |
KM-MFP-BW-A3-181 | No |
No |
Recommended driver:KM-MFP-BW-A3-181 Limitations:Counters for copy and print are shared.Duplex prints are accounted according to parser from job information.Duplex copies are accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 181 | Orion | Yes |
Yes |
No |
Yes |
No |
KM-MFP-BW-A3-181 | No |
No |
Recommended driver:KM-MFP-BW-A3-181 Limitations:Counters for copy and print are shared.Duplex prints are accounted according to parser from job information.Duplex copies are accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-5050 | Falcon 3 | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP2 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | KM-4050 | Falcon 3 | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP2 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | KM-3050 | Falcon 3 | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP2 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | KM-5035 | Falcon 2 | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP | No |
No |
Recommended driver:KM-KYO-MFP Limitations:Counters are same for copy and print. There are 5 seconds timeouts after copy and print. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-4035 | Falcon 2 | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP | No |
No |
Recommended driver:KM-KYO-MFP Limitations:Counters are same for copy and print. There are 5 seconds timeouts after copy and print. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-3035 | Falcon 2 | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP | No |
No |
Recommended driver:KM-KYO-MFP Limitations:Counters are same for copy and print. There are 5 seconds timeouts after copy and print. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-3060 | Stratos | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP | No |
No |
Recommended driver:KM-KYO-MFP Limitations:Counters are same for copy and print. There are 5 seconds timeouts after copy and print. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-2560 | Stratos | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP | No |
No |
Recommended driver:KM-KYO-MFP Limitations:Counters are same for copy and print. There are 5 seconds timeouts after copy and print. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-3530 | Falcon 1 | Yes |
Yes |
No |
Yes |
Yes |
KM-BW-MFP-A3-DUP-3530 | No |
No |
Recommended driver: KM-BW-MFP-A3-DUP-3530 Limitations: Driver supports English language setting of the device. Duplex pages are accounted as simplex. Each A3 page is accounted as two A4 pages. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-2530 | Falcon 1 | Yes |
Yes |
No |
Yes |
Yes |
KM-BW-MFP-A3-DUP-3530 | No |
No |
Recommended driver: KM-BW-MFP-A3-DUP-3530 Limitations: Driver supports English language setting of the device. Duplex pages are accounted as simplex. Each A3 page is accounted as two A4 pages. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | KM-2030 | Atlantis MFP | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP2 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | KM-2550 | Atlantis MFP | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP2 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | KM-2050 | Atlantis MFP | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP2 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | KM-1650 | Atlantis MFP | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP2 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-6026cdn | Yes |
No |
Yes |
Yes |
No |
KM-MFP-COL-A4-M6026 | No |
No |
Recommended driver:KM-MFP-COL-A4-M6026 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-6030MFP | Matsuri | Yes |
Yes |
No |
Yes |
No |
KM-KYO-MFP-FS_6025 | No |
No |
Recommended driver:KM-KYO-MFP-FS_6025 Limitations:Counters are same for copy and print. Duplex is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-6025MFP | Matsuri | Yes |
Yes |
No |
Yes |
No |
KM-KYO-MFP-FS_6025 | No |
No |
Recommended driver:KM-KYO-MFP-FS_6025 Limitations:Counters are same for copy and print. Duplex is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-C850 | Yes |
No |
No |
Yes |
Yes |
KM-COL-MFP | No |
No |
Recommended driver:KM-COL-MFP Limitations:If reading of moFALSEcolor counters failed, try to use driver for same devices without moFALSEcolor. This driver supports moFALSEcolor accounting. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-C830 | Yes |
No |
Yes |
Yes |
Yes |
KM-COL-MFP | No |
No |
Recommended driver:KM-COL-MFP Limitations:If reading of moFALSEcolor counters failed, try to use driver for same devices without moFALSEcolor. This driver supports moFALSEcolor accounting. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-C5250 | Gemini Printer | No |
No |
Yes |
Yes |
No |
KM-KYO-PRN-C5250DN | No |
No |
Recommended driver:KM-KYO-PRN-C5250DN Limitations:English and Hungarian language support for device status.Driver accounts A4 black-and-white duplex print job as A4 black-and-white simplex print job. Driver accounts A4 color duplex print job as A4 color simplex print job. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-C5150 | Gemini Printer | No |
No |
Yes |
Yes |
No |
KM-KYO-PRN-C5250DN | No |
No |
Recommended driver:KM-KYO-PRN-C5250DN Limitations:English and Hungarian language support for device status.Driver accounts A4 black-and-white duplex print job as A4 black-and-white simplex print job. Driver accounts A4 color duplex print job as A4 color simplex print job. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-C5020N | No |
No |
Yes |
Yes |
Yes |
KM-COL-PRN-5020 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C1020MFP | Pluto | Yes |
No |
Yes |
Yes |
No |
KM-KYO-MFP-1020 | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | KM-1018 | Yes |
Yes |
No |
Yes |
Yes |
KM-KYO-MFP2 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-4300DN | 6th Generation | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS4100DN | No |
No |
Recommended driver:KM-PRN-BW-A4-FS4100DN Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-4200DN | 6th Generation | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS4100DN | No |
No |
Recommended driver:KM-PRN-BW-A4-FS4100DN Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-4100DN | 6th Generation | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS4100DN | No |
No |
Recommended driver:KM-PRN-BW-A4-FS4100DN Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-2100DN | 6th Generation | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS4100DN | No |
No |
Recommended driver:KM-PRN-BW-A4-FS4100DN Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-2100D | 6th Generation | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS4100DN | No |
No |
Recommended driver:KM-PRN-BW-A4-FS4100DN Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-4000DN | 5th Generation | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS3920DN-V2 | No |
No |
Recommended driver:KM-PRN-BW-A4-FS3920DN-V2 Limitations:Status detection is supported for following languages: English, Hungarian.Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-2900DN | 5th Generation | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS3920DN-V2 | No |
No |
Recommended driver:KM-PRN-BW-A4-FS3920DN-V2 Limitations:Status detection is supported for following languages: English, Hungarian.Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-2000DN | 5th Generation | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS3920DN-V2 | No |
No |
Recommended driver:KM-PRN-BW-A4-FS3920DN-V2 Limitations:Status detection is supported for following languages: English, Hungarian.Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-3830N | Endeavour | No |
No |
No |
Yes |
No |
KM-RFC-PRN-V2 | No |
No |
Recommended driver:KM-RFC-PRN-V2 Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-3820N | Endeavour | No |
No |
No |
Yes |
No |
KM-RFC-PRN-V2 | No |
No |
Recommended driver:KM-RFC-PRN-V2 Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-3800 | Waverly | No |
No |
No |
Yes |
No |
KM-KYO-PRN | No |
No |
No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-920 | Tornado | No |
No |
No |
Yes |
No |
KM-RFC-PRN-V2 | No |
No |
Recommended driver:KM-RFC-PRN-V2 Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | FS-1900 | No |
No |
No |
Yes |
No |
KM-RFC-PRN-V2 | No |
No |
Recommended driver:KM-RFC-PRN-V2 Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-1010 | No |
No |
No |
Yes |
No |
KM-RFC-PRN-V2 | No |
No |
Recommended driver:KM-RFC-PRN-V2 Limitations:Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | FS-1018 | Yes |
Yes |
No |
Yes |
No |
KM-KYO-MFP2 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | ECOSYS P3055dn | No |
No |
No |
Yes |
No |
No |
No |
Yes |
Untested |
No |
No |
No |
No |
IPP Accounting available with limitation LIMIT-177
|
|||
Kyocera Mita | TaskAlfa 820 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Kyocera Mita | TaskAlfa 205c | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Kyocera Mita | KM-C2630D | Mirage | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | KM-C2630 | Mirage | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | TASKalfa 7550ci | Mercury | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | TASKalfa 6550ci | Mercury | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | TASKalfa 8000i | Zeus | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | TASKalfa 6500i | Zeus | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C8650DN | Venus Printer | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C8600DN | Venus Printer | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C8500DN | Saturn Printer | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C8026 | Magic | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C5400DN | Treasure | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C5350DN | Cassiopeia 30 | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C5300N | Cassiopeia | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C5200N | Cassiopeia | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C5100N | Cassiopeia | No |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-9520DN | Hornet 2 | No |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-9120DN | Hornet 2 | No |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | KM-1118MFP | Discovery MFP | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C2126MFP+ | Gemini L | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | FS-C2026MFP+ | Gemini L | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | TASKalfa 750c | Broad Peak | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | TASKalfa 650c | Broad Peak | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Kyocera Mita | ECOSYS P5026 series | No |
No |
Yes |
Yes |
No |
KM-KYO-PRN-C5250DN | No |
No |
Recommended driver: KM-KYO-PRN-C5250DN Limitations: English and Hungarian language support for device status. Driver accounts A4 black-and-white duplex print job as A4 black-and-white simplex print job. Driver accounts A4 color duplex print job as A4 color simplex print job. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | ECOSYS P2040 series | No |
No |
No |
Yes |
No |
KM-PRN-BW-A4-FS4100DN | No |
No |
Recommended driver: KM-PRN-BW-A4-FS4100DN Limitations: Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | TASKalfa 3011i | Yes |
Yes |
No |
Yes |
Yes |
KM-MFP-BW-A3-TA3501I | No |
No |
Recommended driver: KM-MFP-BW-A3-TA3501I Limitations: Each A3 page is accounted as 2xA4 pages. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | TASKalfa 3511i | Yes |
Yes |
No |
Yes |
Yes |
KM-MFP-BW-A3-TA3501I | No |
No |
Recommended driver: KM-MFP-BW-A3-TA3501I Limitations: Each A3 page is accounted as 2xA4 pages. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | 4002i | TASKalfa | Yes |
Yes |
No |
Yes |
No |
KM-MFP-COL-A3-TA3051C | No |
No |
Recommended driver: KM-MFP-BW-A3-TA3501I Limitations: Each A3 page is accounted as 2xA4 pages. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | 5002i | TASKalfa | Yes |
Yes |
No |
Yes |
No |
KM-MFP-COL-A3-TA3051C | No |
No |
Recommended driver: KM-MFP-BW-A3-TA3501I Limitations: Each A3 page is accounted as 2xA4 pages. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | 6002i | TASKalfa | Yes |
Yes |
No |
Yes |
No |
KM-MFP-BW-A3-TA3501I | No |
No |
Recommended driver: KM-MFP-BW-A3-TA3501I Limitations: Each A3 page is accounted as 2xA4 pages. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
|
Kyocera Mita | TASKalfa 6052ci | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051C | No |
No |
Recommeded driver: KM-MFP-COL-A3-TA3051CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | TASKalfa 5052ci | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051C | No |
No |
Recommeded driver: KM-MFP-COL-A3-TA3051CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | TASKalfa 4052ci | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051C | No |
No |
Recommeded driver: KM-MFP-COL-A3-TA3051CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | TASKalfa 3552ci | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051C | No |
No |
Recommeded driver: KM-MFP-COL-A3-TA3051CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | TASKalfa 3252ci | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051C | No |
No |
Recommeded driver: KM-MFP-COL-A3-TA3051CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
||
Kyocera Mita | TASKalfa 2552ci | Yes |
Yes |
Yes |
Yes |
Yes |
KM-MFP-COL-A3-TA3051C | No |
No |
Recommeded driver: KM-MFP-COL-A3-TA3051CI Limitations: Each A3 page is accounted as two A4 pages. MoFALSEcolor copy counter starts from 1. Status detection during scan transfer is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
||
Lanier | 1013 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 124 | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 245 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 235 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 230 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 225 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 270 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2238C | Yes |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2232C | Yes |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 228C | Yes |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2220 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2105 EB-105EX | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2105 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2090 EB-105EX | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2090 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 175 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 160 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 151 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2045e | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2045 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2035e | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2035 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2032 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2027 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2022 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2020D | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2020 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2018D | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2018 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2016 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 2015 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1515 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1232C | Yes |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1224C | Yes |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1075 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1060 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1045 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1035 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1032 | No |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1027 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1022 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1018D | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1018 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1015 | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | 1013F | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lanier | MP 5002 | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-4002 | No |
No |
Recommended driver:RICOH-MFP-BW-A3-4002 Limitations:FALSEne | Yes |
Yes |
No |
No |
Yes |
No |
SDK/J 10.x Payment System not supported on SafeQ 5
|
|
Lanier | MP 4002 | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-4002 | No |
No |
Recommended driver:RICOH-MFP-BW-A3-4002 Limitations:FALSEne | Yes |
Yes |
No |
No |
Yes |
No |
SDK/J 10.x Payment System not supported on SafeQ 5
|
|
Lanier | MP C7500 Series | Aficio MP C6000/C7500 Series | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Lanier | MP C6000 Series | Aficio MP C6000/C7500 Series | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Lanier | MP 3350 Series | Aficio MP 2550/3350 Series | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Lanier | MP 2550 Series | Russian-C5c | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Lanier | MP 5000 Series | Alex C1c | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Lanier | MP 4000 Series | Alex C1b | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Lexmark | CS521dn | No |
No |
No |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Lexmark | CS622de | No |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
No |
||||
Lexmark | XM7355 | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | XM7370 | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | XC8160 | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Yes |
No |
No |
No |
No |
||||
Lexmark | CX860 | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||||
Lexmark | XM5370 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | XM5365 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | XM9165 | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
||||
Lexmark | XM9155 | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
||||
Lexmark | XM9145 | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
||||
Lexmark | XM1246 | Yes |
No |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
||||
Lexmark | CX924 | CX920 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | CX923 | CX920 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | CX922 | CX920 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | CX921 | CX920 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | XC9265 | CX920 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | XC9255 | CX920 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | XC9245 | CX920 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | XC9235 | CX920 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | XC4240 | Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
firmware FW5.3.23 and later recommended
|
|||
Lexmark | CX622 | CX62x | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
firmware FW5.3.23 and later recommended
|
||
Lexmark | CX625 | CX62x | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
firmware FW5.3.23 and later recommended
|
||
Lexmark | MX826 | MX82x | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Lexmark | MX822 | MX82x | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Lexmark | MX722 | MX72x | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | MX721 | MX72x | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | MX522 | MX52x | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Lexmark | MX521 | MX52x | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Limited solutions device - does not support Embedded terminal application.
|
||
Lexmark | MX622 | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Untested |
No |
No |
No |
Yes |
||||
Lexmark | XC4150 | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL-A3-X9xxde | No |
No |
Recommended driver: LEXMARK-MFP-COL-A3-X9xxde Limitations: Duplex print is detected from print job. Duplex copy is accounted as simplex copy. A3 print/copy is accounted as A4 print/copy. Device does FALSEt send accounting information during sleep mode. Status detection is supported for following device language settings: English | Yes |
Yes |
No |
No |
Yes |
Yes |
||
Lexmark | XC4140 | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL-A3-X9xxde | No |
No |
Recommended driver: LEXMARK-MFP-COL-A3-X9xxde Limitations: Duplex print is detected from print job. Duplex copy is accounted as simplex copy. A3 print/copy is accounted as A4 print/copy. Device does FALSEt send accounting information during sleep mode. Status detection is supported for following device language settings: English | No |
Untested |
No |
No |
No |
No |
||
Lexmark | C950 | No |
Yes |
Yes |
Yes |
No |
LEXMARK-MFP-COL-A3-C925 | No |
No |
Recommended driver:LEXMARK-MFP-COL-A3-C925 Limitations:Duplex print is detected from print job.A3 print is accounted as A4 print.Status detection is supported for following device language settings: English, Hungarian.During wakeup device can be busy up to 1 second. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | C925 | No |
Yes |
Yes |
Yes |
No |
LEXMARK-MFP-COL-A3-C925 | No |
No |
Recommended driver:LEXMARK-MFP-COL-A3-C925 Limitations:Duplex print is detected from print job.A3 print is accounted as A4 print.Status detection is supported for following device language settings: English, Hungarian.During wakeup device can be busy up to 1 second. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | C736 | No |
No |
Yes |
Yes |
No |
LEXMARK-PRN-COL-A4-C736 | No |
No |
Recommended driver:LEXMARK-PRN-COL-A4-C736 Limitations:Duplex is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | C734 | No |
No |
Yes |
Yes |
No |
LEXMARK-PRN-COL-A4-C736 | No |
No |
Recommended driver:LEXMARK-PRN-COL-A4-C736 Limitations:Duplex is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | W820 | No |
Yes |
No |
Yes |
No |
LEXMARK-W | No |
No |
Recommended driver:LEXMARK-W Limitations:Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X658 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP-X656de | No |
No |
Recommended driver:LEXMARK-MFP-X656de Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X656 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP-X656de | No |
No |
Recommended driver:LEXMARK-MFP-X656de Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X654 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP-X656de | No |
No |
Recommended driver:LEXMARK-MFP-X656de Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X652 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP-X656de | No |
No |
Recommended driver:LEXMARK-MFP-X656de Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X364 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP-BW-A4-DUP | No |
No |
Recommended driver:LEXMARK-MFP-BW-A4-DUP Limitations:Status detection is supported for following languages: English, Hungarian.Duplex print is accounted according to parser from job information.Device must have eco mode switched off. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X363 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP-BW-A4-DUP | No |
No |
Recommended driver:LEXMARK-MFP-BW-A4-DUP Limitations:Status detection is supported for following languages: English, Hungarian.Duplex print is accounted according to parser from job information.Device must have eco mode switched off. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X264 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP-BW-A4-DUP | No |
No |
Recommended driver:LEXMARK-MFP-BW-A4-DUP Limitations:Status detection is supported for following languages: English, Hungarian.Duplex print is accounted according to parser from job information.Device must have eco mode switched off. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X466 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP-X466de | No |
No |
Recommended driver:LEXMARK-MFP-X466de Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X464 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP-X466de | No |
No |
Recommended driver:LEXMARK-MFP-X466de Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X463 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP-X466de | No |
No |
Recommended driver:LEXMARK-MFP-X466de Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X864 | Yes |
Yes |
No |
Yes |
No |
LEXMARK-MFP-X860 | No |
No |
Recommended driver:LEXMARK-MFP-X860 Limitations:Duplex print is detected from print job.Duplex copy is accounted as simplex copy.Counters for copy and print are shared.Each A3 page is accounted as A4 page.There is 3 second timeout after print/copy.Odd number of A3 duplex print/copy pages will be accounted with one more page. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X862 | Yes |
Yes |
No |
Yes |
No |
LEXMARK-MFP-X860 | No |
No |
Recommended driver:LEXMARK-MFP-X860 Limitations:Duplex print is detected from print job.Duplex copy is accounted as simplex copy.Counters for copy and print are shared.Each A3 page is accounted as A4 page.There is 3 second timeout after print/copy.Odd number of A3 duplex print/copy pages will be accounted with one more page. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X860 | Yes |
Yes |
No |
Yes |
No |
LEXMARK-MFP-X860 | No |
No |
Recommended driver:LEXMARK-MFP-X860 Limitations:Duplex print is detected from print job.Duplex copy is accounted as simplex copy.Counters for copy and print are shared.Each A3 page is accounted as A4 page.There is 3 second timeout after print/copy.Odd number of A3 duplex print/copy pages will be accounted with one more page. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | CX410de | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL-A3-X9xxde | No |
No |
Recommended driver:LEXMARK-MFP-COL-A3-X9xxde Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. A3 print/copy is accounted as A4 print/copy. Device does FALSEt send accounting information during sleep mode. Status detection is supported for following device language settings: English | No |
Untested |
No |
No |
No |
No |
||
Lexmark | CS510 | No |
No |
Yes |
Yes |
No |
LEXMARK-PRN-COL-A4-C792 | No |
No |
Recommended driver:LEXMARK-PRN-COL-A4-C792 Limitations:Duplex print is accounted according to parser from job information.Status detection is supported for following languages: English, French, German, Spanish, Portuguese, Swedish, Danish, Finnish, FALSErse, Dutch, Russian, Polish and Greek. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | CS410 | No |
No |
Yes |
Yes |
No |
LEXMARK-PRN-COL-A4-C792 | No |
No |
Recommended driver:LEXMARK-PRN-COL-A4-C792 Limitations:Duplex print is accounted according to parser from job information.Status detection is supported for following languages: English, French, German, Spanish, Portuguese, Swedish, Danish, Finnish, FALSErse, Dutch, Russian, Polish and Greek. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | CS310 | No |
No |
Yes |
Yes |
No |
LEXMARK-PRN-COL-A4-C792 | No |
No |
Recommended driver:LEXMARK-PRN-COL-A4-C792 Limitations:Duplex print is accounted according to parser from job information.Status detection is supported for following languages: English, French, German, Spanish, Portuguese, Swedish, Danish, Finnish, FALSErse, Dutch, Russian, Polish and Greek. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | MS812 | No |
No |
No |
Yes |
No |
LEXMARK-MS812de | No |
No |
Recommended driver:LEXMARK-MS812de Limitations:Duplex print is detected from print job. There is 4 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | MS811 | No |
No |
No |
Yes |
No |
LEXMARK-MS812de | No |
No |
Recommended driver:LEXMARK-MS812de Limitations:Duplex print is detected from print job. There is 4 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | MS810 | No |
No |
No |
Yes |
No |
LEXMARK-MS812de | No |
No |
Recommended driver:LEXMARK-MS812de Limitations:Duplex print is detected from print job. There is 4 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | MS610 | No |
No |
No |
Yes |
No |
LEXMARK-MS812de | No |
No |
Recommended driver:LEXMARK-MS812de Limitations:Duplex print is detected from print job. There is 4 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | MS510 | No |
No |
No |
Yes |
No |
LEXMARK-MS812de | No |
No |
Recommended driver:LEXMARK-MS812de Limitations:Duplex print is detected from print job. There is 4 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | MS410 | No |
No |
No |
Yes |
No |
LEXMARK-MS812de | No |
No |
Recommended driver:LEXMARK-MS812de Limitations:Duplex print is detected from print job. There is 4 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | MS310 | No |
No |
No |
Yes |
No |
LEXMARK-MS812de | No |
No |
Recommended driver:LEXMARK-MS812de Limitations:Duplex print is detected from print job. There is 4 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | MX510 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP | No |
No |
Recommended driver:LEXMARK-MFP Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. There is a 4 second timeout after print. There is a 4 second timeout after copy. | Yes |
Yes |
No |
No |
Yes |
No |
||
Lexmark | MX511 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP | No |
No |
Recommended driver:LEXMARK-MFP Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. There is a 4 second timeout after print. There is a 4 second timeout after copy. | Yes |
Yes |
No |
No |
Yes |
Yes |
||
Lexmark | MX710 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP | No |
No |
Recommended driver:LEXMARK-MFP Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. There is a 4 second timeout after print. There is a 4 second timeout after copy. | Yes |
Yes |
No |
No |
Yes |
No |
PS print driver recommended
|
|
Lexmark | MX711 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP | No |
No |
Recommended driver:LEXMARK-MFP Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. There is a 4 second timeout after print. There is a 4 second timeout after copy. | Yes |
Yes |
No |
No |
Yes |
No |
PS print driver recommended
|
|
Lexmark | MX611 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP | No |
No |
Recommended driver:LEXMARK-MFP Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. There is a 4 second timeout after print. There is a 4 second timeout after copy. | Yes |
Yes |
No |
No |
Yes |
No |
||
Lexmark | MX610 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP | No |
No |
Recommended driver:LEXMARK-MFP Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. There is a 4 second timeout after print. There is a 4 second timeout after copy. | Yes |
Yes |
No |
No |
Yes |
No |
||
Lexmark | MX411 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP | No |
No |
Recommended driver:LEXMARK-MFP Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. There is a 4 second timeout after print. There is a 4 second timeout after copy. | Yes |
Untested |
No |
No |
Yes |
No |
USB card reader is not supported by MFD
|
|
Lexmark | MX410 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP | No |
No |
Recommended driver:LEXMARK-MFP Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. There is a 4 second timeout after print. There is a 4 second timeout after copy. | Yes |
Untested |
No |
No |
Yes |
No |
USB card reader is not supported by MFD
|
|
Lexmark | MX812 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP | No |
No |
Recommended driver:LEXMARK-MFP Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. There is a 4 second timeout after print. There is a 4 second timeout after copy. | Yes |
Yes |
No |
No |
Yes |
No |
||
Lexmark | MX811 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP | No |
No |
Recommended driver:LEXMARK-MFP Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. There is a 4 second timeout after print. There is a 4 second timeout after copy. | Yes |
Yes |
No |
No |
Yes |
No |
||
Lexmark | MX810 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP | No |
No |
Recommended driver:LEXMARK-MFP Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. There is a 4 second timeout after print. There is a 4 second timeout after copy. | Yes |
Yes |
No |
No |
Yes |
No |
||
Lexmark | MX310 | Yes |
No |
No |
Yes |
No |
LEXMARK-MFP | No |
No |
Recommended driver:LEXMARK-MFP Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. There is a 4 second timeout after print. There is a 4 second timeout after copy. | Yes |
Yes |
No |
No |
Yes |
No |
||
Lexmark | X792 | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL | No |
No |
Recommended driver:LEXMARK-MFP-COL Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Device does FALSEt send accounting information during sleep mode.Status detection is supported for following device language settings: English, German.When device goes out of paper during job processing, job may be accounted as 0 pages.There is a 5 seconds timeout after print.There is a 5 seconds timeout after copy. | Yes |
Yes |
No |
No |
Yes |
No |
PS print driver recommended
|
|
Lexmark | X748 | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL | No |
No |
Recommended driver:LEXMARK-MFP-COL Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Device does FALSEt send accounting information during sleep mode.Status detection is supported for following device language settings: English, German.When device goes out of paper during job processing, job may be accounted as 0 pages.There is a 5 seconds timeout after print.There is a 5 seconds timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X746 | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL | No |
No |
Recommended driver:LEXMARK-MFP-COL Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Device does FALSEt send accounting information during sleep mode.Status detection is supported for following device language settings: English, German.When device goes out of paper during job processing, job may be accounted as 0 pages.There is a 5 seconds timeout after print.There is a 5 seconds timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X738 | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL | No |
No |
Recommended driver:LEXMARK-MFP-COL Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Device does FALSEt send accounting information during sleep mode.Status detection is supported for following device language settings: English, German.When device goes out of paper during job processing, job may be accounted as 0 pages.There is a 5 seconds timeout after print.There is a 5 seconds timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X736 | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL | No |
No |
Recommended driver:LEXMARK-MFP-COL Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Device does FALSEt send accounting information during sleep mode.Status detection is supported for following device language settings: English, German.When device goes out of paper during job processing, job may be accounted as 0 pages.There is a 5 seconds timeout after print.There is a 5 seconds timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X734 | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL | No |
No |
Recommended driver:LEXMARK-MFP-COL Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Device does FALSEt send accounting information during sleep mode.Status detection is supported for following device language settings: English, German.When device goes out of paper during job processing, job may be accounted as 0 pages.There is a 5 seconds timeout after print.There is a 5 seconds timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X548 | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL | No |
No |
Recommended driver:LEXMARK-MFP-COL Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Device does FALSEt send accounting information during sleep mode.Status detection is supported for following device language settings: English, German.When device goes out of paper during job processing, job may be accounted as 0 pages.There is a 5 seconds timeout after print.There is a 5 seconds timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X546 | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL | No |
No |
Recommended driver:LEXMARK-MFP-COL Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Device does FALSEt send accounting information during sleep mode.Status detection is supported for following device language settings: English, German.When device goes out of paper during job processing, job may be accounted as 0 pages.There is a 5 seconds timeout after print.There is a 5 seconds timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X544 | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL | No |
No |
Recommended driver:LEXMARK-MFP-COL Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Device does FALSEt send accounting information during sleep mode.Status detection is supported for following device language settings: English, German.When device goes out of paper during job processing, job may be accounted as 0 pages.There is a 5 seconds timeout after print.There is a 5 seconds timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X543 | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL | No |
No |
Recommended driver:LEXMARK-MFP-COL Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Device does FALSEt send accounting information during sleep mode.Status detection is supported for following device language settings: English, German.When device goes out of paper during job processing, job may be accounted as 0 pages.There is a 5 seconds timeout after print.There is a 5 seconds timeout after copy. | No |
Untested |
No |
No |
No |
No |
||
Lexmark | X925 | Yes |
Yes |
Yes |
Yes |
No |
LEXMARK-MFP-COL-A3-X9xxde | No |
No |
Recommended driver:LEXMARK-MFP-COL-A3-X9xxde Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. A3 print/copy is accounted as A4 print/copy. Device does FALSEt send accounting information during sleep mode. Status detection is supported for following device language settings: English | Yes |
Yes |
No |
No |
Yes |
No |
||
Lexmark | X954 | Yes |
Yes |
Yes |
Yes |
No |
LEXMARK-MFP-COL-A3-X9xxde | No |
No |
Recommended driver:LEXMARK-MFP-COL-A3-X9xxde Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. A3 print/copy is accounted as A4 print/copy. Device does FALSEt send accounting information during sleep mode. Status detection is supported for following device language settings: English | Yes |
Untested |
No |
No |
Yes |
Yes |
YSoft SafeQ 5 MU31+ recommended
|
|
Lexmark | X952 | Yes |
Yes |
Yes |
Yes |
No |
LEXMARK-MFP-COL-A3-X9xxde | No |
No |
Recommended driver:LEXMARK-MFP-COL-A3-X9xxde Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. A3 print/copy is accounted as A4 print/copy. Device does FALSEt send accounting information during sleep mode. Status detection is supported for following device language settings: English | Yes |
Untested |
No |
No |
Yes |
No |
YSoft SafeQ 5 MU31+ recommended
|
|
Lexmark | X950 | Yes |
Yes |
Yes |
Yes |
No |
LEXMARK-MFP-COL-A3-X9xxde | No |
No |
Recommended driver:LEXMARK-MFP-COL-A3-X9xxde Limitations:Duplex print is detected from print job. Duplex copy is accounted as simplex copy. A3 print/copy is accounted as A4 print/copy. Device does FALSEt send accounting information during sleep mode. Status detection is supported for following device language settings: English | Yes |
Untested |
No |
No |
Yes |
No |
YSoft SafeQ 5 MU31+ recommended
|
|
Lexmark | X560n | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL-A4-X560 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | T654 | No |
No |
No |
Yes |
No |
LEXMARK-T | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | Optra T612 | No |
No |
No |
Yes |
No |
LEXMARK-T | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | E460dn | No |
No |
No |
Yes |
No |
LEXMARK-T | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | E450dn | No |
No |
No |
Yes |
No |
LEXMARK-T | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | E360 | No |
No |
No |
Yes |
No |
LEXMARK-T | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | E352dn | No |
No |
No |
Yes |
No |
LEXMARK-T | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | E120n | No |
No |
No |
Yes |
No |
LEXMARK-T | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | T644 | No |
No |
No |
Yes |
No |
LEXMARK-T | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | T640 | No |
No |
No |
Yes |
No |
LEXMARK-T | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | T632 | No |
No |
No |
Yes |
No |
LEXMARK-T | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | T630 | No |
No |
No |
Yes |
No |
LEXMARK-T | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | T520 | No |
No |
No |
Yes |
No |
LEXMARK-T | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | MS622de | No |
No |
No |
Yes |
No |
No |
Yes |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | CX825, CX820 | CX82x | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Lexmark | MS521 | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | CX522 | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
No |
Yes |
No |
No |
No |
Yes |
||||
Lexmark | XM1242 | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
Limited solutions device - does not support Embedded terminal application.
|
|||
Lexmark | MX912 | MX91x | Yes |
Yes |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
|||
Lexmark | MX911 | MX91x | Yes |
Yes |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
|||
Lexmark | MX910 | MX91x | Yes |
Yes |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
|||
Lexmark | xs796 | Yes |
No |
Yes |
Yes |
No |
SAFEQ-29619 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Lexmark | W840 | No |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | X854 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | X852 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | X850 | Yes |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | X342n | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | X340 | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | X646 | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | X642 | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | X945 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | X940 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | C792 | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | C748 | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | C746 | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | C546 | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | C544 | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | C543 | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | C540 | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | C935 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Lexmark | CX725 | CX72x | Yes |
No |
Yes |
Yes |
No |
LEXMARK-MFP-COL-A3-X9xxde | No |
Yes |
Recommended driver: LEXMARK-MFP-COL-A3-X9xxde Limitations: Duplex print is detected from print job. Duplex copy is accounted as simplex copy. A3 print/copy is accounted as A4 print/copy. Device does FALSEt send accounting information during sleep mode. Status detection is supported for following device language settings: English | Yes |
Yes |
No |
No |
Yes |
Yes |
|
Lexmark | MX953se | Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
||||
Lexmark | CX635 | CX63x | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Lexmark | CX951se, CX950se | CX95x | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | CX963se, CX962se, CX961se, CS963e | CX96x | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
SAFEQ Cloud embedded terminal support since 2024.10.03 version. |
||
Lexmark | CX833se | CX83x | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
SAFEQ Cloud embedded terminal support since 2024.10.03 version. |
||
Lexmark | CX532adwe | CX53x | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Lexmark | MX632 | MX63x | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Lexmark | MX432adwe | MX43x | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Lexmark | MX931 | MX93x | Yes |
Yes |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | CX730, CX735 | CX73x | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | CX944, CX943, CX942 | CX94x | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | CX931, CX930 | CX93x | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | CX431 | CX43x | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | MX431 | MX43x | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | MX421 | MX42x | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Lexmark | MX331 | MX33x | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | CX331 | CX33x | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | CX421 | CX42x | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|||
Lexmark | MX321 | MX32x | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Lexmark | MX532adwe | MX53x | Yes |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|||
Lexmark | CS632 | CS63x | No |
No |
No |
Yes |
No |
No |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
|||
Muratec | MFX 3091 | Oki MB 471 | Yes |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Muratec | MFX C2700 | Oki MC 561 | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Muratec | MFX 4580N | KM BH 364e KM BH 454e | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-XXXE | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-A3-XXXE Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information. | Yes |
Yes |
No |
No |
Yes |
No |
|
Muratec | MFX 3680N | KM BH 364e KM BH 454e | Yes |
Yes |
No |
Yes |
No |
MIFALSELTA-MFP-BW-A3-XXXE | No |
No |
Recommended driver:MIFALSELTA-MFP-BW-A3-XXXE Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information. | Yes |
Yes |
No |
No |
Yes |
No |
|
Muratec | MFX C5580N | KM BH C224e - BH C554e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
|
Muratec | MFX C4580N | KM BH C224e - BH C554e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
|
Muratec | MFX C3680N | KM BH C224e - BH C554e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
|
Muratec | MFX C2880N | KM BH C224e - BH C554e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
|
Muratec | MFX C2280N | KM BH C224e - BH C554e | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver: MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
|
Muratec | MFX 3530 | KM BH25e | Yes |
No |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
Embedded terminal not supported.
|
||
Nashuatec | MP 2352SP | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Nashuatec | MP C3501 | MP | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Nashuatec | MP C3001 | MP | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Nashuatec | MP 5000 Series | Alex C1c | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Nashuatec | MP 4000 Series | Alex C1b | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Oce | PlotWave 365 | No |
No |
No |
Yes |
No |
OFFLINE-PLOTTER | No |
No |
Recommended driver:OFFLINE-PLOTTER Limitations:Please enable rendering jobs as high-resolution (150 DPI) images to use this driver.This driver uses coverage accounting to account paper formats larger than A3 in multiples of A4. | No |
Untested |
No |
No |
No |
No |
||
Oce | PlotWave 345 | No |
No |
No |
Yes |
No |
OFFLINE-PLOTTER | No |
No |
Recommended driver:OFFLINE-PLOTTER Limitations:Please enable rendering jobs as high-resolution (150 DPI) images to use this driver.This driver uses coverage accounting to account paper formats larger than A3 in multiples of A4. | No |
Untested |
No |
No |
No |
No |
||
Oce | VarioLink 5022 | Yes |
Yes |
No |
Yes |
Yes |
OCE-MFP-COL | No |
No |
Recommended driver:OCE-MFP-COL Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub 501.
|
|
Oce | VarioLink 4222 | Yes |
Yes |
No |
Yes |
Yes |
OCE-MFP-COL | No |
No |
Recommended driver:OCE-MFP-COL Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub 421.
|
|
Oce | VarioPrint (RFC) | Yes |
Yes |
No |
Yes |
Yes |
OCE-RFC | No |
No |
Recommended driver:OCE-RFC Limitations:Enhanced detection of device status. Counters for copy and print are shared. SNMP community is set to oce_operator in default. LPR queue name is set to PRINT in default | No |
Untested |
No |
No |
No |
No |
||
Oce | VarioPrint 2090 | Yes |
Yes |
No |
Yes |
Yes |
OCE | No |
No |
Recommended driver:OCE Limitations:Enhanced detection of device status. SNMP community is set to oce_operator in default. LPR queue name is set to PRINT in default. | No |
Untested |
No |
No |
No |
No |
||
Oce | VarioPrint 2071 | Yes |
Yes |
No |
Yes |
Yes |
OCE-MFP-BW-A3-DUP | No |
No |
Recommended driver:OCE-MFP-BW-A3-DUP Limitations:Enhanced detection of device status. SNMP community is set to oce_operator in default. LPR queue name is set to PRINT in default. Scan counters are supported by this driver. | No |
Untested |
No |
No |
No |
No |
||
Oce | VarioPrint 2070 | Yes |
Yes |
No |
Yes |
Yes |
OCE | No |
No |
Recommended driver:OCE Limitations:Enhanced detection of device status. SNMP community is set to oce_operator in default. LPR queue name is set to PRINT in default. | No |
Untested |
No |
No |
No |
No |
||
Oce | VarioPrint 2065 | Yes |
Yes |
No |
Yes |
Yes |
OCE | No |
No |
Recommended driver:OCE Limitations:Enhanced detection of device status. SNMP community is set to oce_operator in default. LPR queue name is set to PRINT in default. | No |
Untested |
No |
No |
No |
No |
||
Oce | VarioPrint 2060 | Yes |
Yes |
No |
Yes |
Yes |
OCE | No |
No |
Recommended driver:OCE Limitations:Enhanced detection of device status. SNMP community is set to oce_operator in default. LPR queue name is set to PRINT in default. | No |
Untested |
No |
No |
No |
No |
||
Oce | VarioPrint 2055 | Yes |
Yes |
No |
Yes |
Yes |
OCE | No |
No |
Recommended driver:OCE Limitations:Enhanced detection of device status. SNMP community is set to oce_operator in default. LPR queue name is set to PRINT in default. | No |
Untested |
No |
No |
No |
No |
||
Oce | VarioPrint 2050 | Yes |
Yes |
No |
Yes |
Yes |
OCE | No |
No |
Recommended driver:OCE Limitations:Enhanced detection of device status. SNMP community is set to oce_operator in default. LPR queue name is set to PRINT in default. | No |
Untested |
No |
No |
No |
No |
||
Oce | VarioPrint 2045 | Yes |
Yes |
No |
Yes |
Yes |
OCE | No |
No |
Recommended driver:OCE Limitations:Enhanced detection of device status. SNMP community is set to oce_operator in default. LPR queue name is set to PRINT in default. | No |
Untested |
No |
No |
No |
No |
||
Oce | VarioPrint 1075 | Yes |
Yes |
No |
Yes |
Yes |
OCE-MFP-BW | No |
No |
Recommended driver:OCE-MFP-BW Limitations:Additional busy state recognition from number of active jobs. SNMP community is set to oce_operator in default. LPR queue name is set to PRINT in default. | No |
Untested |
No |
No |
No |
No |
||
Oce | VarioPrint 1065 | Yes |
Yes |
No |
Yes |
Yes |
OCE-MFP-BW | No |
No |
Recommended driver:OCE-MFP-BW Limitations:Additional busy state recognition from number of active jobs. SNMP community is set to oce_operator in default. LPR queue name is set to PRINT in default. | No |
Untested |
No |
No |
No |
No |
||
Oce | VarioPrint 1055 | Yes |
Yes |
No |
Yes |
Yes |
OCE-MFP-BW | No |
No |
Recommended driver:OCE-MFP-BW Limitations:Additional busy state recognition from number of active jobs. SNMP community is set to oce_operator in default. LPR queue name is set to PRINT in default. | No |
Untested |
No |
No |
No |
No |
||
Oce | VarioLink 6522c | Yes |
Yes |
Yes |
Yes |
Yes |
OCE-MFP-COL-A3-4552 | No |
No |
Recommended driver:OCE-MFP-COL-A3-4552 Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub c652.
|
|
Oce | VarioLink 5522c | Yes |
Yes |
Yes |
Yes |
Yes |
OCE-MFP-COL-A3-4552 | No |
No |
Recommended driver:OCE-MFP-COL-A3-4552 Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub c552.
|
|
Oce | VarioLink 4522c | Yes |
Yes |
Yes |
Yes |
Yes |
OCE-MFP-COL-A3-4552 | No |
No |
Recommended driver:OCE-MFP-COL-A3-4552 Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub c452.
|
|
Oce | VarioLink 3622c | Yes |
Yes |
Yes |
Yes |
Yes |
OCE-MFP-COL | No |
No |
Recommended driver:OCE-MFP-COL Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub c360.
|
|
Oce | VarioLink 2822c | Yes |
Yes |
Yes |
Yes |
Yes |
OCE-MFP-COL | No |
No |
Recommended driver:OCE-MFP-COL Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub c280.
|
|
Oce | VarioLink 2222c | Yes |
Yes |
Yes |
Yes |
Yes |
OCE-MFP-COL | No |
No |
Recommended driver:OCE-MFP-COL Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub c220.
|
|
Oce | CS250 | Yes |
Yes |
Yes |
Yes |
Yes |
OCE-MFP-COL | No |
No |
Recommended driver:OCE-MFP-COL Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub c650.
|
|
Oce | CS240 | Yes |
Yes |
Yes |
Yes |
Yes |
OCE-MFP-COL | No |
No |
Recommended driver:OCE-MFP-COL Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub c550.
|
|
Oce | CS231 | Yes |
Yes |
Yes |
Yes |
Yes |
OCE-MFP-COL | No |
No |
Recommended driver:OCE-MFP-COL Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub c451.
|
|
Oce | CS193 | Yes |
Yes |
Yes |
Yes |
Yes |
OCE-MFP-COL | No |
No |
Recommended driver:OCE-MFP-COL Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub c353.
|
|
Oce | CS173 | Yes |
Yes |
Yes |
Yes |
Yes |
OCE-MFP-COL | No |
No |
Recommended driver:OCE-MFP-COL Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub c253.
|
|
Oce | CS163 | Yes |
Yes |
Yes |
Yes |
Yes |
OCE-MFP-COL | No |
No |
Recommended driver:OCE-MFP-COL Limitations:There are 3 seconds timeouts after copy and print. Duplex for printing is detected from job | No |
Untested |
No |
No |
No |
No |
Rebranded KM bizhub c203.
|
|
Oce | CS115 | Yes |
Yes |
Yes |
Yes |
Yes |
OCE-CS115 | No |
No |
Recommended driver:OCE-CS115 Limitations:Driver for keycountered device. Driver is in online mode only for state detection | No |
Untested |
No |
No |
No |
No |
||
Oce | 31x5 (RFC) | Yes |
Yes |
No |
Yes |
Yes |
OCE-RFC | No |
No |
Recommended driver:OCE-RFC Limitations:Enhanced detection of device status. Counters for copy and print are shared. SNMP community is set to oce_operator in default. LPR queue name is set to PRINT in default | No |
Untested |
No |
No |
No |
No |
||
Oki | C841dn | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Oki | C811dn | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Oki | B841dn | No |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Oki | B801n | No |
Yes |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Oki | MC560 | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Oki | C5550MFP | Yes |
No |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Oki | C941dn | No |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Oki | B4545 | Yes |
No |
No |
Yes |
No |
No |
No |
Online accounting driver for this device canFALSEt be created. Reason:Device does FALSEt change statuses. Result:Offline accounting only. | No |
Untested |
No |
No |
No |
No |
|||
Oki | MC573 | Yes |
No |
Yes |
Yes |
No |
OKI-MFP-COL-A4-MC573 | No |
No |
Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. Duplex jobs having odd number of pages can be accounted with one more black and white page. Status detection is supported for following device language settings: English. Device does FALSEt send accounting information during sleep mode. | No |
Yes |
Yes |
No |
Yes |
No |
YSoft SafeQ 5 MU39+ recommended for Embedded terminal.
LD device from YSoft SafeQ 6 MU17.
|
|
Oki | MB492 | Yes |
No |
No |
Yes |
No |
OKI-MFP-DUP-MB451 | No |
No |
Recommended driver: OKI-MFP-DUP-MB451 Limitations: Duplex print is accounted according to parser from job information. Duplex copy is accounted as simplex. | No |
Yes |
No |
No |
Yes |
No |
FW: A03.23_0_5 CU and newer
LD device from YSoft SafeQ 6 MU17.
|
|
Oki | ES4192 | Yes |
No |
No |
Yes |
No |
OKI-MFP-DUP-MB451 | No |
No |
Recommended driver:OKI-MFP-DUP-MB451 Limitations:Duplex print is accounted according to parser from job information. Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Oki | B721 | No |
No |
No |
Yes |
No |
OKI-PRN-BW-A4-B731 | No |
No |
Recommended driver:OKI-PRN-BW-A4-B731 Limitations: Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. | No |
Untested |
No |
No |
No |
No |
||
Oki | MPS5501b | No |
No |
No |
Yes |
No |
OKI-PRN-BW-A4-B731 | No |
No |
Recommended driver:OKI-PRN-BW-A4-B731 Limitations: Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. | No |
Untested |
No |
No |
No |
No |
||
Oki | B731 | No |
No |
No |
Yes |
No |
OKI-PRN-BW-A4-B731 | No |
No |
Recommended driver:OKI-PRN-BW-A4-B731 Limitations: Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES7131 | No |
No |
No |
Yes |
No |
OKI-PRN-BW-A4-B731 | No |
No |
Recommended driver:OKI-PRN-BW-A4-B731 Limitations: Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. | No |
Untested |
No |
No |
No |
No |
||
Oki | B512 | No |
No |
No |
Yes |
No |
OKI-PRN-BW-A4-ES4132 | No |
No |
Recommended driver:OKI-PRN-BW-A4-ES4132 Limitations: Duplex jobs having odd number of pages can be accounted with one more page. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES5112 | No |
No |
No |
Yes |
No |
OKI-PRN-BW-A4-ES4132 | No |
No |
Recommended driver:OKI-PRN-BW-A4-ES4132 Limitations: Duplex jobs having odd number of pages can be accounted with one more page. | No |
Untested |
No |
No |
No |
No |
||
Oki | B432 | No |
No |
No |
Yes |
No |
OKI-PRN-BW-A4-ES4132 | No |
No |
Recommended driver:OKI-PRN-BW-A4-ES4132 Limitations: Duplex jobs having odd number of pages can be accounted with one more page. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES4132 | No |
No |
No |
Yes |
No |
OKI-PRN-BW-A4-ES4132 | No |
No |
Recommended driver:OKI-PRN-BW-A4-ES4132 Limitations: Duplex jobs having odd number of pages can be accounted with one more page. | No |
Untested |
No |
No |
No |
No |
||
Oki | B4600 | No |
No |
No |
Yes |
No |
OKI-PRN-BW-B4600-MSG | No |
No |
Recommended driver:OKI-PRN-BW-B4600-MSG Limitations: Duplex print is detected from print job parser. Status detection is supported for following languages: English. | No |
Untested |
No |
No |
No |
No |
||
Oki | B4350 | No |
No |
No |
Yes |
No |
OKI-PRN-BW-B4600-MSG | No |
No |
Recommended driver:OKI-PRN-BW-B4600-MSG Limitations: Duplex print is detected from print job parser. Status detection is supported for following languages: English. | No |
Untested |
No |
No |
No |
No |
||
Oki | C531 | No |
No |
Yes |
Yes |
No |
OKI-PRN-COL-A4-ES5431 | No |
No |
Recommended driver:OKI-PRN-COL-A4-ES5431 Limitations:If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES5431 | No |
No |
Yes |
Yes |
No |
OKI-PRN-COL-A4-ES5431 | No |
No |
Recommended driver:OKI-PRN-COL-A4-ES5431 Limitations:If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES9475 | Weiss H | Yes |
Yes |
Yes |
Yes |
Yes |
TOSHIBA-MFP-COL-A3-ALLFORMATS | No |
No |
Recommended driver:TOSHIBA-MFP-COL-A3-ALLFORMATS Limitations: Duplex print is accounted according to parser from job information.Enhanced detection of device status.Additional busy state recognition from job state. | No |
Yes |
No |
No |
Yes |
No |
ET supported since YSoft SafeQ 5 CU1
|
Oki | ES9465 | Weiss H | Yes |
Yes |
Yes |
Yes |
Yes |
TOSHIBA-MFP-COL-A3-ALLFORMATS | No |
No |
Recommended driver:TOSHIBA-MFP-COL-A3-ALLFORMATS Limitations: Duplex print is accounted according to parser from job information.Enhanced detection of device status.Additional busy state recognition from job state. | No |
Yes |
No |
No |
Yes |
No |
ET supported since YSoft SafeQ 5 CU1
|
Oki | ES9455 | Weiss L | Yes |
Yes |
Yes |
Yes |
Yes |
TOSHIBA-MFP-BW2-A3-ALLFORMATSv2 | No |
No |
Recommended driver:TOSHIBA-MFP-BW2-A3-ALLFORMATSv2 Limitations:Enhanced detection of device status.Additional busy state recognition from job state.Duplex print is accounted according to parser from job information. | No |
Yes |
No |
No |
Yes |
No |
ET supported since YSoft SafeQ 5 CU1
|
Oki | 9170 | Yes |
Yes |
No |
Yes |
Yes |
TOSHIBA-MFP-BW-A4-256 | No |
No |
Recommended driver:TOSHIBA-MFP-BW-A4-256 Limitations:Duplex print is accounted according to parser from job information. | No |
Yes |
No |
No |
Yes |
No |
ET supported since YSoft SafeQ 5 CU1
|
|
Oki | ES9160 | Yes |
Yes |
No |
Yes |
Yes |
TOSHIBA-MFP-BW-A4-256 | No |
No |
Recommended driver:TOSHIBA-MFP-BW-A4-256 Limitations:Duplex print is accounted according to parser from job information. | No |
Yes |
No |
No |
Yes |
No |
ET supported since YSoft SafeQ 5 CU1
|
|
Oki | ES7170 MFP | Yes |
No |
No |
Yes |
Yes |
OKI-MFP-BW-A4-ES7170MFP | No |
No |
Recommended driver: OKI-MFP-BW-A4-ES7170MFP Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Scan menu canFALSEt be blocked by blocking cable. Offline accounting is FALSEt yet supported by blocking cable. | No |
Yes |
No |
No |
Yes |
No |
ET supported since firmware version 2240. Version 2301 recommended for optimal experience ET supported since YSoft SafeQ 5 CU1
|
|
Oki | ES7160 MFP | Yes |
No |
No |
Yes |
Yes |
OKI-MFP-BW-A4-ES7170MFP | No |
No |
Recommended driver: OKI-MFP-BW-A4-ES7170MFP Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Scan menu canFALSEt be blocked by blocking cable. Offline accounting is FALSEt yet supported by blocking cable. | No |
Yes |
No |
No |
Yes |
No |
ET supported since firmware version 2240. Version 2301 recommended for optimal experience ET supported since YSoft SafeQ 5 CU1
|
|
Oki | ES7480 MFP | Yes |
No |
Yes |
Yes |
Yes |
OKI-MFP-COL-A4-ES7470 | No |
No |
Recommended driver: OKI-MFP-COL-A4-ES7470 Limitations:There is a 6 seconds timeout after print.There is a 6 seconds timeout after copy.Scan menu canFALSEt be blocked by blocking cable.Offline accounting is FALSEt yet supported by blocking cable. | No |
Yes |
No |
No |
Yes |
No |
ET supported since firmware version 2240. Version 2301 recommended for optimal experience ET supported since YSoft SafeQ 5 CU1
|
|
Oki | ES7470 MFP | Yes |
No |
Yes |
Yes |
Yes |
OKI-MFP-COL-A4-ES7470 | No |
No |
Recommended driver: OKI-MFP-COL-A4-ES7470 Limitations:There is a 6 seconds timeout after print.There is a 6 seconds timeout after copy.Scan menu canFALSEt be blocked by blocking cable.Offline accounting is FALSEt yet supported by blocking cable. | No |
Yes |
No |
No |
Yes |
No |
ET supported since firmware version 2240. Version 2301 recommended for optimal experience ET supported since YSoft SafeQ 5 CU1
|
|
Oki | ES7460 MFP | Yes |
No |
Yes |
Yes |
Yes |
OKI-MFP-COL-A4-ES7470 | No |
No |
Recommended driver: OKI-MFP-COL-A4-ES7470 Limitations:There is a 6 seconds timeout after print.There is a 6 seconds timeout after copy.Scan menu canFALSEt be blocked by blocking cable.Offline accounting is FALSEt yet supported by blocking cable. | No |
Yes |
No |
No |
Yes |
No |
ET supported since firmware version 2240. Version 2301 recommended for optimal experience ET supported since YSoft SafeQ 5 CU1
|
|
Oki | MB770 | Yes |
No |
No |
Yes |
Yes |
OKI-MFP-BW-A4-MB760 | No |
No |
Recommended driver: OKI-MFP-BW-A4-MB760 Limitations:Duplex copy is accounted as simplex. | No |
Yes |
No |
No |
Yes |
No |
ET supported since firmware version 2240. Version 2301 recommended for optimal experience ET supported since YSoft SafeQ 5 CU1
|
|
Oki | MB760 | Yes |
No |
No |
Yes |
Yes |
OKI-MFP-BW-A4-MB760 | No |
No |
Recommended driver: OKI-MFP-BW-A4-MB760 Limitations:Duplex copy is accounted as simplex. | No |
Yes |
No |
No |
Yes |
No |
ET supported since firmware version 2240. Version 2301 recommended for optimal experience ET supported since YSoft SafeQ 5 CU1
|
|
Oki | MC780 | Yes |
No |
Yes |
Yes |
Yes |
OKI-MFP-COL-A4-MC760 | No |
No |
Recommended driver: OKI-MFP-COL-A4-MC760 Limitations: Duplex copy is accounted as simplex. | No |
Yes |
No |
No |
Yes |
No |
ET supported since firmware version 2240. Version 2301 recommended for optimal experience ET supported since YSoft SafeQ 5 CU1
|
|
Oki | MC770 | Yes |
No |
Yes |
Yes |
Yes |
OKI-MFP-COL-A4-MC760 | No |
No |
Recommended driver:OKI-MFP-COL-A4-MC760 Limitations:Duplex copy is accounted as simplex. | No |
Yes |
No |
No |
Yes |
No |
ET supported since firmware version 2240. Version 2301 recommended for optimal experience ET supported since YSoft SafeQ 5 CU1
|
|
Oki | MC760 | Yes |
No |
Yes |
Yes |
Yes |
OKI-MFP-COL-A4-MC760 | No |
No |
Recommended driver:OKI-MFP-COL-A4-MC760 Limitations:Duplex copy is accounted as simplex. | No |
Yes |
No |
No |
Yes |
No |
ET supported since firmware version 2240. Version 2301 recommended for optimal experience ET supported since YSoft SafeQ 5 CU1
|
|
Oki | ES9470 | Yes |
Yes |
Yes |
Yes |
Yes |
OKI-MFP-COL-A3-ES9460 | No |
No |
Recommended driver:OKI-MFP-COL-A3-ES9460 Limitations:ADF must be closed down to logout from terminal.SafeQ server sends job to the MFP even if there is FALSE paper in the device.Enhanced detection of device status.Additional busy state recognition from job state.Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.MoFALSEcolor/two-color copies/prints are accounted as color. | No |
Yes |
No |
No |
Yes |
No |
ET supported since YSoft SafeQ 5 CU1
|
|
Oki | ES9460 | Yes |
Yes |
Yes |
Yes |
Yes |
OKI-MFP-COL-A3-ES9460 | No |
No |
Recommended driver:OKI-MFP-COL-A3-ES9460 Limitations:ADF must be closed down to logout from terminal.SafeQ server sends job to the MFP even if there is FALSE paper in the device.Enhanced detection of device status.Additional busy state recognition from job state.Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.MoFALSEcolor/two-color copies/prints are accounted as color. | No |
Yes |
No |
No |
Yes |
No |
ET supported since YSoft SafeQ 5 CU1
|
|
Oki | ES4131 | No |
No |
No |
Yes |
No |
OKI-PRN-BW-A4-B431DN | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Oki | B431 | No |
No |
No |
Yes |
No |
OKI-PRN-BW-A4-B431DN | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Oki | B430 | No |
No |
No |
Yes |
No |
OKI-PRN-BW-A4-B430DN | No |
No |
Recommended driver:OKI-PRN-BW-A4-B430DN Limitations:Duplex print is accounted according to parser from job information.There is a 5 seconds timeout after print. | No |
Untested |
No |
No |
No |
No |
||
Oki | B411 | No |
No |
No |
Yes |
No |
OKI-PRN-BW-A4-B431DN | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Oki | ES4191 | Yes |
No |
Yes |
Yes |
Yes |
OKI-MFP-BW-A4-ES4191 | No |
No |
Recommended driver:OKI-MFP-BW-A4-ES4191 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.When tray is opened during print / copy, job may FALSEt be accounted correctly. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES8441dn | No |
Yes |
Yes |
Yes |
No |
OKI-PRN-COL-A3-C841 | No |
No |
Recommended driver:OKI-PRN-COL-A3-C841 Limitations:Device is FALSEt ready during sleep mode (FALSEt power save mode).Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES8431dn | No |
Yes |
Yes |
Yes |
No |
OKI-PRN-COL-A3-C841 | No |
No |
Recommended driver:OKI-PRN-COL-A3-C841 Limitations:Device is FALSEt ready during sleep mode (FALSEt power save mode).Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
Oki | C841 | No |
Yes |
Yes |
Yes |
No |
OKI-PRN-COL-A3-C841 | No |
No |
Recommended driver:OKI-PRN-COL-A3-C841 Limitations:Device is FALSEt ready during sleep mode (FALSEt power save mode).Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
Oki | C831 | No |
Yes |
Yes |
Yes |
No |
OKI-PRN-COL-A3-C841 | No |
No |
Recommended driver:OKI-PRN-COL-A3-C841 Limitations:Device is FALSEt ready during sleep mode (FALSEt power save mode).Duplex print is accounted according to parser from job information. | No |
Untested |
No |
No |
No |
No |
||
Oki | C711 | No |
No |
Yes |
Yes |
No |
OKI-PRN-COL-A4-C610 | No |
No |
Recommended driver:OKI-PRN-COL-A4-C610 Limitations:Duplex print is accounted according to parser from job information.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | C610 | No |
No |
Yes |
Yes |
No |
OKI-PRN-COL-A4-C610 | No |
No |
Recommended driver:OKI-PRN-COL-A4-C610 Limitations:Duplex print is accounted according to parser from job information.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES8483 MFP | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES8473 MFP | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES8463 MFP | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES8453 MFP | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | MC883 | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | MC873 | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | MC863 | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | MC853 | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES8461 MFP | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES8451 MFP | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | MC861 | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | MC851 | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES8460 MFP | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | MC860 | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-A3-MC860 | No |
No |
Recommended driver:OKI-MFP-COL-A3-MC860 Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.A3 scans are accounted as 2xA4.Device is FALSEt ready for authentication during sleep mode. Device must be woken up before authentication or direct print. This does FALSEt apply when SNMPv3 is used. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES5461 MFP | Yes |
No |
Yes |
Yes |
No |
OKI-MFP-COL-MC561 | No |
No |
Recommended driver:OKI-MFP-COL-MC561 Limitations:All duplex prints/copies are accounted as simplex. Status detection is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
||
Oki | MC561 | Yes |
No |
Yes |
Yes |
No |
OKI-MFP-COL-MC561 | No |
No |
Recommended driver:OKI-MFP-COL-MC561 Limitations:All duplex prints/copies are accounted as simplex. Status detection is FALSEt supported. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES5462 MFP | Yes |
No |
Yes |
Yes |
No |
OKI-MFP-COL-MC352 | No |
No |
Recommended driver:OKI-MFP-COL-MC352 Limitations:Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. Duplex jobs having odd number of pages can be accounted with one more black and white page. Status detection is supported for following device language settings: English. Device does FALSEt send accounting information during sleep mode. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES3452 MFP | Yes |
No |
Yes |
Yes |
No |
OKI-MFP-COL-MC352 | No |
No |
Recommended driver:OKI-MFP-COL-MC352 Limitations:Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. Duplex jobs having odd number of pages can be accounted with one more black and white page. Status detection is supported for following device language settings: English. Device does FALSEt send accounting information during sleep mode. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES3451 MFP | Yes |
No |
Yes |
Yes |
No |
OKI-MFP-COL-MC352 | No |
No |
Recommended driver:OKI-MFP-COL-MC352 Limitations:Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. Duplex jobs having odd number of pages can be accounted with one more black and white page. Status detection is supported for following device language settings: English. Device does FALSEt send accounting information during sleep mode. | No |
Untested |
No |
No |
No |
No |
||
Oki | MC562 | No |
No |
No |
Yes |
No |
OKI-MFP-COL-MC352 | No |
No |
Recommended driver:OKI-MFP-COL-MC352 Limitations:Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. Duplex jobs having odd number of pages can be accounted with one more black and white page. Status detection is supported for following device language settings: English. Device does FALSEt send accounting information during sleep mode. | No |
Untested |
No |
No |
No |
No |
||
Oki | MC352dn | No |
No |
No |
Yes |
No |
OKI-MFP-COL-MC352 | No |
No |
Recommended driver:OKI-MFP-COL-MC352 Limitations:Duplex copy is accounted as simplex. Duplex print is accounted according to parser from job information. Duplex jobs having odd number of pages can be accounted with one more black and white page. Status detection is supported for following device language settings: English. Device does FALSEt send accounting information during sleep mode. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES5162 MFP | Yes |
No |
No |
Yes |
No |
OKI-MFP-DUP-MB451 | No |
No |
Recommended driver:OKI-MFP-DUP-MB451 Limitations:Duplex print is accounted according to parser from job information. Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Oki | MB562 | Yes |
No |
No |
Yes |
No |
OKI-MFP-DUP-MB451 | No |
No |
Recommended driver: OKI-MFP-DUP-MB451 Limitations: Duplex print is accounted according to parser from job information. Duplex copy is accounted as simplex. LD license eligible | No |
Yes |
Yes |
No |
Yes |
No |
||
Oki | ES4161 MFP | Yes |
No |
No |
Yes |
No |
OKI-MFP-DUP-MB451 | No |
No |
Recommended driver:OKI-MFP-DUP-MB451 Limitations:Duplex print is accounted according to parser from job information. Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Oki | MB461 | Yes |
No |
No |
Yes |
No |
OKI-MFP-DUP-MB451 | No |
No |
Recommended driver:OKI-MFP-DUP-MB451 Limitations:Duplex print is accounted according to parser from job information. Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Oki | MB441 | Yes |
No |
No |
Yes |
No |
OKI-MFP-DUP-MB451 | No |
No |
Recommended driver:OKI-MFP-DUP-MB451 Limitations:Duplex print is accounted according to parser from job information. Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Oki | MB451 | Yes |
No |
No |
Yes |
No |
OKI-MFP-DUP-MB451 | No |
No |
Recommended driver:OKI-MFP-DUP-MB451 Limitations:Duplex print is accounted according to parser from job information. Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES4151 MFP | Yes |
No |
No |
Yes |
No |
OKI-MFP-DUP-MB451 | No |
No |
Recommended driver:OKI-MFP-DUP-MB451 Limitations:Duplex print is accounted according to parser from job information. Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Oki | B6300n | No |
No |
No |
Yes |
No |
OKI-PRN-BW-A4-B6300N | No |
No |
Recommended driver:OKI-PRN-BW-A4-B6300N Limitations:Status detection is supported only for devices set to English or Polish. | No |
Untested |
No |
No |
No |
No |
||
Oki | B401 | No |
No |
No |
Yes |
No |
OKI-DUP-B401 | No |
No |
Recommended driver:OKI-DUP-B401 Limitations:Duplex print is accounted according to parser from job information. There is 5 second timeout after printing. If printer is out of paper after finishing printing, paper will have to be refilled to finish print job. | No |
Untested |
No |
No |
No |
No |
||
Oki | ES3640 Pro | Yes |
Yes |
Yes |
Yes |
No |
OKI-MFP-COL-MSG | No |
No |
Recommended driver:OKI-MFP-COL-MSG Limitations:Counters count number of letters, FALSEt number of pages.Each A3 letter is accounted as two A4 letters.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Oki | OkiLAN 6500e | Yes |
No |
Yes |
Yes |
No |
OKI-MFP-COL-MSG | No |
No |
Recommended driver:OKI-MFP-COL-MSG Limitations:Counters count number of letters, FALSEt number of pages.Each A3 letter is accounted as two A4 letters.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Oki | OkiLAN 5540e | Yes |
No |
Yes |
Yes |
No |
OKI-MFP-COL-RFC | No |
No |
Recommended driver:OKI-MFP-COL-RFC Limitations:Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Oki | OkiLAN 5510e | Yes |
No |
Yes |
Yes |
No |
OKI-MFP-COL-RFC-GDI | No |
No |
Recommended driver:OKI-MFP-COL-RFC-GDI Limitations:Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Oki | C9850 MFP | Yes |
Yes |
Yes |
Yes |
Yes |
OKI-MFP-C9850 | No |
No |
Recommended driver:OKI-MFP-C9850 Limitations:All color prints/copies are accounted as black and white. All duplex prints/copies are rounded up to even number and accounted as simplex. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
Blocking cable is not yet massively produced. For more information contact your account manager.
|
|
Oki | C9800ga | Yes |
No |
Yes |
Yes |
Yes |
OKI-MFP-COL-MSG | No |
No |
Recommended driver:OKI-MFP-COL-MSG Limitations:Counters count number of letters, FALSEt number of pages.Each A3 letter is accounted as two A4 letters.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Oki | C9800g | Yes |
No |
Yes |
Yes |
Yes |
OKI-MFP-COL-MSG | No |
No |
Recommended driver:OKI-MFP-COL-MSG Limitations:Counters count number of letters, FALSEt number of pages.Each A3 letter is accounted as two A4 letters.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Oki | C7350 | No |
No |
Yes |
Yes |
No |
OKI-PRN-COL-MSG | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Oki | C5450n | No |
No |
Yes |
Yes |
No |
OKI-PRN-COL-RFC | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Oki | C5300 (old) | No |
No |
Yes |
Yes |
No |
OKI-PRN-COL-RFC | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Oki | C5300 | No |
No |
Yes |
Yes |
No |
OKI-PRN-COL-MSG | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Oki | C3200n | No |
No |
Yes |
Yes |
No |
OKI-PRN-COL-MSG-GDI | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Olivetti | d-Color MF25 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Untested |
No |
No |
No |
No |
||||
Olivetti | d-Color MF559 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
SafeQ5
(Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout.
SafeQ6
(Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Gen2 browser) When using SafeQ6 Gen2 terminal, it is recommended to disable certificate validation or create a custom certificate having SAN(Subject Alternative Name) and use it instead and register to bizhub. Terminal server default certificate does not have SAN value.
|
|||
Olivetti | d-Color MF459 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
SafeQ5
(Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout.
SafeQ6
(Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Gen2 browser) When using SafeQ6 Gen2 terminal, it is recommended to disable certificate validation or create a custom certificate having SAN(Subject Alternative Name) and use it instead and register to bizhub. Terminal server default certificate does not have SAN value.
|
|||
Olivetti | d-Color MF369 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
SafeQ5
(Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Browser Terminal) Auto logout by user defined time out only logs out a user from the SQ application. A user needs to press MFD's logout button to logout.
SafeQ6
(Native Terminal) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Gen2 browser) When using SafeQ6 Gen2 terminal, it is recommended to disable certificate validation or create a custom certificate having SAN(Subject Alternative Name) and use it instead and register to bizhub. Terminal server default certificate does not have SAN value.
|
|||
Olivetti | d-Color MF4003 | Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Common Limitations:
MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. Classic UI does not have this issue.
|
|||
Olivetti | d-Color MF25 | Yes |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Common Limitations:
MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. Classic UI does not have this issue.
|
|||
Olivetti | d-Color P3302 | No |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Device has limited OpenAPI - Application icon is not visible, can be added manually via web interface of the device.
Minimum required firmware: GC1-73
Scan application is not supported.
|
|||
Olivetti | d-Color MF754 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
||||
Olivetti | d-Color MF554 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
||||
Olivetti | d-Color MF654 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
||||
Olivetti | d-Color MF3300 | Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
||||
Olivetti | d-Color MF3800 | Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
||||
Olivetti | d-color MF759 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
||||
Olivetti | d-Color MF3302 | Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
Common for SafeQ5 and SafeQ6(MFD limitation with the tested FW version)
MFD's new UI(Basic UI) mode has a bug in controlling access right for 1/2 colors copy. Despite no-access right for color, 1/2 colors copy can be initiated which however ends up in the error when the MFD tries to start copying. This bug will be fixed by IT6v2.0 mass-production FW that is scheduled for release in early October. Classic UI does not have this issue.
When kmOpenApiVersion is set to 4.2, securityProtocolTypesForOutboundCommunication shall include SSL3.0 and/or TLS1.0 and the MFD's SSL version shall be enabled for SSL3.0 and/or TLS1.0 which are not enabled by default on the device. To use TLS1.1 or TLS1.2, set kmOpenApiVersion to 4-13a(default of SafeQ6).
When using SafeQ6 Gen2 terminal, certificate validation shall be disabled in the MFD or the MFD loops the certificate validation message on the browser on logout attempt. Or the solution is to create a custom certificate having SAN(Subject Alternative Name) and use it instead and register to bizhub. Termianl server default certificate does not have SAN value and cannot be trusted so the behavior above occurs.
SafeQ5
(Native TE only) Auto logout by user defined timeout does not work.
(Browser TE) Auto logout by user defined time out only logges out a user from the SQ application. A user needs to press MFD's logout button to logout. System Auto Reset shall be used instead for auto logout.
Logout by card requires DIP SW value change.
SafeQ6
(Native TE only) Auto logout by user defined timeout does not work. System Auto Reset shall be used instead for auto logout.
(Gen2 browser) Certificate validation shall be disabled or the MFD loops showing certificate validation message and behaves strangely when trying to logout. Registering a certificate from the MFD's browser cannot register the cert. Uploading a cert from the administration web also does not solve this behavior
Logout by card requires DIP SW value change.
|
|||
Olivetti | d-Color MF284 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Olivetti | d-Color MF254 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
|||
Olivetti | PG L 450 | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Olivetti | PG L 230 | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Olivetti | PG L 2028SP | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Olivetti | PG L 2028 | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Olivetti | 800 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Olivetti | D-Copia 600 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Olivetti | D-Copia 25 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Olivetti | D-Copia 20 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Olivetti | d-Copia 3513MF | Yes |
No |
No |
Yes |
No |
OLIVETTI-MFP-BW-A4-283MF | No |
No |
Recommended driver:OLIVETTI-MFP-BW-A4-283MF Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | d-Color MF 364 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2, MIFALSELTA-MFP-COL-A3-CXXXE-V3, MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW | No |
No |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is accounted according to parser from job information. Each 2color print is accounted as a color print. Each single color or 2color copy is accounted as a color copy. A device must be set to total counter mode 2. MIFALSELTA-MFP-COL-A3-CXXXE-V3 Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a full-color print. Each 1 color and 2colors copy is accounted as a full-color copy. Each A3 Scan page is accounted as two A4 Scan pages. (Total counter mdoe 2 behavior) Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 2" MFD setting. MIFALSELTA-MFP-COL-A3-CXXXE-V3-M1-BW Limitations: There is a 3 seconds timeout after print. There is a 3 seconds timeout after copy. Duplex print is detected from print job parser. Each 2 colors print is accounted as a BW print. Each 1 color and 2colors copy is accounted as a BW copy. Driver can be set for offline copy accounting. Login during incoming/outgoing FAX is possible when KeyCounter cable is used. This driver is for "total counter mode 1" MFD setting. | Yes |
Yes |
No |
No |
Yes |
No |
To use self-card-registration and billing code (Billing code selection after login) feature use FW version GC1-54 or newer.
|
|
Olivetti | d-Color MF752Plus | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
OpenApi version 3.7.2 supported so far. When blocked withVender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-83
|
|
Olivetti | d-Color MF652Plus | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
OpenApi version 3.7.2 supported so far. When blocked withVender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-83
|
|
Olivetti | d-Color MF552Plus | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
OpenApi version 3.7.2 supported so far. When blocked withVender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Olivetti | d-Color MF452Plus | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
OpenApi version 3.7.2 supported so far. When blocked withVender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Olivetti | d-Color MF362Plus | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
OpenApi version 3.7.2 supported so far. When blocked withVender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Olivetti | d-Color MF282Plus | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | Yes |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
OpenApi version 3.7.2 supported so far. When blocked withVender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Olivetti | d-Color MF222Plus | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | Yes |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
OpenApi version 3.7.2 supported so far. When blocked withVender2 cable, online accounting does not work, machine is not increasing counters. This problem can be solved by using firmware version GD1-63
|
|
Olivetti | d-Color MF752 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB, Memory: 2GB (already built in) Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
|
|
Olivetti | d-Color MF652 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB, Memory: 2GB (already built in) Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
|
|
Olivetti | d-Color MF552 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB and Memory: 2GB built in by default Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
|
|
Olivetti | d-Color MF452 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB and Memory: 2GB built in by default Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
|
|
Olivetti | d-Color MF362 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB and Memory: 2GB built in by default Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
|
|
Olivetti | d-Color MF282 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
No |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB and Memory: 2GB built in by default Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
|
|
Olivetti | d-Color MF222 | Yes |
Yes |
Yes |
Yes |
Yes |
MIFALSELTA-MFP-COL-A3-CXXXE-V2 | No |
Yes |
Recommended driver:MIFALSELTA-MFP-COL-A3-CXXXE-V2 Limitations:There is a 3 seconds timeout after print.There is a 3 seconds timeout after copy.Duplex print is accounted according to parser from job information.Each 2color print is accounted as a color print.Each single color or 2color copy is accounted as a color copy. | Yes |
Yes |
No |
No |
Yes |
No |
Native: HDD: 250GB and Memory: 2GB built in by default Native with MyPanel: HDD: 250GB Memory: 4GB (extended memory UK-204) Browser with/without MyPanel: HDD: 250GB, Memory: 4GB (extended memory UK-204), LK-101v3 iOption License Kit Recommended latest firmware (above G20-58). USB print without re-authentication when using IC card authentication is supported only with OpenAPI 4.0
|
|
Olivetti | d-Color MF2552 | Yes |
Yes |
Yes |
Yes |
No |
OLIVETTI-MFP-COL-A3-MF2552 | No |
No |
Recommended driver:OLIVETTI-MFP-COL-A3-MF2552 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Each A3 page is accounted as two A4 pages. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | d-Color MF2501 | Yes |
Yes |
Yes |
Yes |
No |
OLIVETTI-MFP-COL-A3-MF2001 | No |
No |
Recommended driver:OLIVETTI-MFP-COL-A3-MF2001 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Each A3 page is accounted as two A4 pages. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | d-Color MF2001 | Yes |
Yes |
Yes |
Yes |
No |
OLIVETTI-MFP-COL-A3-MF2001 | No |
No |
Recommended driver:OLIVETTI-MFP-COL-A3-MF2001 Limitations:Duplex copy is accounted as simplex.Duplex print is accounted according to parser from job information.Each A3 page is accounted as two A4 pages. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 400 | Yes |
Yes |
No |
Yes |
Yes |
OLIVETTI | No |
No |
Recommended driver:OLIVETTI Limitations:There are 4 seconds timeout after print and 3 seconds timeout after copy. Driver can be set for offline accounting. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 3504MF | Yes |
No |
No |
Yes |
No |
OLIVETTI-MFP-BW-A4-283MF | No |
No |
Recommended driver:OLIVETTI-MFP-BW-A4-283MF Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 3503MF | Yes |
No |
No |
Yes |
No |
OLIVETTI-MFP-BW-A4-283MF | No |
No |
Recommended driver:OLIVETTI-MFP-BW-A4-283MF Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 3004MF | Yes |
No |
No |
Yes |
No |
OLIVETTI-MFP-BW-A4-283MF | No |
No |
Recommended driver:OLIVETTI-MFP-BW-A4-283MF Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 3003MF | Yes |
No |
No |
Yes |
No |
OLIVETTI-MFP-BW-A4-283MF | No |
No |
Recommended driver:OLIVETTI-MFP-BW-A4-283MF Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | d-Copia 2200MF | Yes |
Yes |
No |
Yes |
No |
OLIVETTI-MFP-BW-A3-1800MF | No |
No |
Recommended driver:OLIVETTI-MFP-BW-A3-1800MF Limitations:Counters for copy and print are shared.Duplex prints are accounted according to parser from job information.Duplex copies are accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 1800MF | Yes |
Yes |
No |
Yes |
No |
OLIVETTI-MFP-BW-A3-1800MF | No |
No |
Recommended driver:OLIVETTI-MFP-BW-A3-1800MF Limitations:Counters for copy and print are shared.Duplex prints are accounted according to parser from job information.Duplex copies are accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | 284MF | Yes |
No |
No |
Yes |
No |
OLIVETTI-MFP-BW-A4-283MF | No |
No |
Recommended driver:OLIVETTI-MFP-BW-A4-283MF Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 283MF | Yes |
No |
No |
Yes |
No |
OLIVETTI-MFP-BW-A4-283MF | No |
No |
Recommended driver:OLIVETTI-MFP-BW-A4-283MF Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | 404MF | Yes |
No |
No |
Yes |
No |
OLIVETTI-MFP-BW-A4-283MF | No |
No |
Recommended driver:OLIVETTI-MFP-BW-A4-283MF Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 403MF | Yes |
No |
No |
Yes |
No |
OLIVETTI-MFP-BW-A4-283MF | No |
No |
Recommended driver:OLIVETTI-MFP-BW-A4-283MF Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 500MF | Yes |
Yes |
No |
Yes |
Yes |
OLIVETTI-MFP-BW | No |
No |
Recommended driver:OLIVETTI-MFP-BW Limitations:Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 400MF | Yes |
Yes |
No |
Yes |
Yes |
OLIVETTI-MFP-BW | No |
No |
Recommended driver:OLIVETTI-MFP-BW Limitations:Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 300MF | Yes |
Yes |
No |
Yes |
Yes |
OLIVETTI-MFP-BW | No |
No |
Recommended driver:OLIVETTI-MFP-BW Limitations:Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 300 | Yes |
Yes |
No |
Yes |
Yes |
OLIVETTI | No |
No |
Recommended driver:OLIVETTI Limitations:There are 4 seconds timeout after print and 3 seconds timeout after copy. Driver can be set for offline accounting. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 250MF | Yes |
Yes |
No |
Yes |
Yes |
OLIVETTI-200 | No |
No |
Recommended driver:OLIVETTI-200 Limitations:There are 4 seconds timeout after print and 3 seconds timeout after copy. Driver can be set for offline accounting. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 200MF | Yes |
Yes |
No |
Yes |
Yes |
OLIVETTI | No |
No |
Recommended driver:OLIVETTI Limitations:There are 4 seconds timeout after print and 3 seconds timeout after copy. Driver can be set for offline accounting. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 25MF | Yes |
Yes |
No |
Yes |
Yes |
OLIVETTI | No |
No |
Recommended driver:OLIVETTI Limitations:There are 4 seconds timeout after print and 3 seconds timeout after copy. Driver can be set for offline accounting. Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 18MF | Yes |
Yes |
No |
Yes |
Yes |
OLIVETTI-MFP-BW-A4-283MF | No |
No |
Recommended driver:OLIVETTI-MFP-BW-A4-283MF Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex. | No |
Untested |
No |
No |
No |
No |
||
Olivetti | D-Copia 16MF | Yes |
Yes |
No |
Yes |
Yes |
OLIVETTI-MFP-BW-A4-283MF | No |
No |
Recommended driver:OLIVETTI-MFP-BW-A4-283MF Limitations:Duplex print is accounted according to parser from job information.Duplex copy is accounted as simplex.Counters for copy and print are shared. | No |
Untested |
No |
No |
No |
No |
||
Pantum | M7200 | Yes |
No |
No |
Yes |
No |
PANTUM-MFP-BW-A4 | No |
No |
Recommended driver: PANTUM-MFP-BW-A4 Limitations: Counters for copy and print are shared. Status message is FALSEt available. Duplex is detected from job information by job parser. | No |
Untested |
No |
No |
No |
No |
||
Pantum | M7100 | Yes |
No |
No |
Yes |
No |
PANTUM-MFP-BW-A4 | No |
No |
Recommended driver: PANTUM-MFP-BW-A4 Limitations: Counters for copy and print are shared. Status message is FALSEt available. Duplex is detected from job information by job parser. | No |
Untested |
No |
No |
No |
No |
||
Rex Rotary | MP C3501 | MP | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Rex Rotary | MP C3001 | MP | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Rex Rotary | MP 5000 Series | Alex C1c | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Rex Rotary | MP 4000 Series | Alex C1b | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Rex Rotary | MP 2550 | Russian-C5c | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Yes |
No |
No |
No |
No |
SDK/J 4.0.x F Display: WVGA (800x480)
|
||
Rex Rotary | MP 2352SP | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | IM C2010 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
||||
Ricoh | IM C6010, C6010SD | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||||
Ricoh | IM C5510, C5510A | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||||
Ricoh | IM C4510, C4510SD, C4510A | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||||
Ricoh | IM C3510, C3510SD | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||||
Ricoh | IM C3010, C3010SD | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||||
Ricoh | IM 370F | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
||||
Ricoh | IM 460F | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
||||
Ricoh | IM 6000 | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
|
|||
Ricoh | IM 5000 | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
Ricoh SOP Embedded terminal:
- Java J/SDK not required
|
|||
Ricoh | IM 4000 | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
Ricoh SOP Embedded terminal:
- Java J/SDK not required
|
|||
Ricoh | IM 3500 | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Untested |
No |
Yes |
No |
Yes |
Ricoh SOP Embedded terminal:
- Java J/SDK not required
|
|||
Ricoh | IM 3000 | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Ricoh SOP Embedded terminal:
- Java J/SDK not required
|
|||
Ricoh | IM 2500 | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
Ricoh SOP Embedded terminal:
- Java J/SDK not required
|
|||
Ricoh | IM C530F/FB | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Ricoh SOP Embedded terminal:
- Java J/SDK not required
|
|||
Ricoh | Pro C5310s | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Ricoh SOP based terminal.
YSoft SafeQ 6 Build 55 and newer recommended.
|
|||
Ricoh | Pro C5300s | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Ricoh SOP based terminal.
YSoft SafeQ 6 Build 55 and newer recommended.
|
|||
Ricoh | P 801 | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 Build 55
|
|||
Ricoh | P 501 | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 Build 55
|
|||
Ricoh | P 502 | No |
No |
No |
Yes |
No |
No |
No |
No |
Untested |
Yes |
No |
No |
No |
LD device from YSoft SafeQ 6 Build 55
|
|||
Ricoh | MP C6503 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
No |
No |
Yes |
Ricoh SOP Embedded terminal:
- J/SDK is optional.
|
|||
Ricoh | MP 6503 | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
No |
Untested |
No |
No |
No |
Yes |
Ricoh SOP Embedded terminal:
- J/SDK is optional.
|
|||
Ricoh | MP 7503 | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
Ricoh SOP Embedded terminal:
- J/SDK is optional.
|
|||
Ricoh | MP 9003 | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
|
|||
Ricoh | IM 600 | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
||||
Ricoh | IM 550 | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
||||
Ricoh | IM 2702 | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Yes |
||||
Ricoh | IM C6500 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
Ricoh Embedded Terminal
J/SDK 12.x required
not tested
Ricoh SOP Embedded Terminal
Tested FW version: 1.03(System/Copy), 1.03:02(Engine)
SafeQ 6 build 46 to 48 requires the EAP license “YSQL6-083-0000”. General availability is from build 49.
Web API token in Build 46 has only limited validity (2 months), after 2 months a new token with 2 years validity has to be obtained (or update to a newer Build has to be performed).
Charging and quotas are not supported.
J/SDK not required
|
|||
Ricoh | MP C501 | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Ricoh Embedded terminal:
- Java J/SDK 12.x and HDD required
Ricoh SOP Embedded terminal:
- J/SDK is optional.
|
|||
Ricoh | IM C6000 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Ricoh Embedded terminal:
- Java J/SDK 12.x required
Ricoh SOP Embedded terminal:
- Java J/SDK not required
|
|||
Ricoh | IM C5500 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Ricoh Embedded terminal:
- Java J/SDK 12.x required
Ricoh SOP Embedded terminal:
- Java J/SDK not required
|
|||
Ricoh | IM C4500 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Ricoh Embedded terminal:
- Java J/SDK 12.x required
Ricoh SOP Embedded terminal:
- Java J/SDK not required
|
|||
Ricoh | IM C3000 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
|
|||
Ricoh | MP C8003 | Yes |
Yes |
Yes |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Ricoh Embedded terminal
SDK 11.x HDD required. Display: WVGA (800x480)
Scanning into 1/2 colors and grayscale are not supported by the device.-
1/2 colors: Documents are scanned in Full color
Grayscale: Documents are scanned in BW
multiple PDF: Documents are scanned in separate PDF files.
Ricoh SOP Embedded terminal
J/SDK is optional.
|
|||
Ricoh | SP C360 | Yes |
No |
Yes |
Yes |
No |
RICOH-MFP-COL-A4-C360-PRTONLY2 | No |
No |
RICOH-MFP-COL-A4-C360-PRTONLY2 Limitations: If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. Only print counters are checked. Copies are igFALSEred. Suitable for direct queues. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | MP 6055 | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-255 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Ricoh Embedded terminal:
- Java J/SDK 12.x and HDD required
Ricoh SOP Embedded terminal:
- J/SDK is optional.
|
||
Ricoh | MP 402 | Yes |
No |
No |
Yes |
No |
Yes |
Yes |
request SAFEQ-45141, SAFEQ-42947 | Yes |
Yes |
No |
No |
Yes |
Yes |
Ricoh Embedded terminal:
- Java J/SDK 12.x and HDD required
Ricoh SOP Embedded terminal:
- J/SDK is optional.
|
||
Ricoh | IPSiO SP C711 | No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio SP C320DN | No |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio SP C831DN | No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio SP C830DN | No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio SP C730DN | No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio SP C821DN | No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio SP C820DN | No |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio SP 8300DN | No |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio AP610N | No |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio AP2610N | No |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio AP2610 | No |
Yes |
No |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio MP C401 | Yes |
No |
Yes |
Yes |
Yes |
Yes |
Yes |
Beta driver is available for certification. Offline accounting is supported. * All devices (incl. devices FALSEt covered by the list) are compatible with YSoft SafeQ offline accounting provided they support PCL, Post Script or HPGL print language. | Yes |
Yes |
No |
No |
Yes |
Yes |
|
||
Ricoh | Pro 8100EX | Yes |
Yes |
No |
Yes |
No |
No |
No |
Online accounting driver was FALSEt requested yet. Offline accounting is supported.* All devices (incl. devices FALSEt covered by the list) are compatible with YSoft SafeQ offline accounting provided they support PCL, Post Script or HPGL print language. | No |
Untested |
No |
No |
No |
No |
|||
Ricoh | Aficio MP C4051 | Yes |
Yes |
Yes |
Yes |
No |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio MP 5001 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
No |
SDK/J 4.0.x F HDD required. Display: WVGA (800x480)
|
|||
Ricoh | Aficio MP 4001 | Yes |
Yes |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
No |
No |
Yes |
No |
SDK/J 4.0.x F HDD required. Display: WVGA (800x480)
|
|||
Ricoh | Aficio Color 4506 (E-310 v1.0) | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio Color 3506 | Yes |
Yes |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | Aficio MP 171SPF | Yes |
No |
Yes |
Yes |
Yes |
No |
No |
No |
Untested |
No |
No |
No |
No |
||||
Ricoh | IM 9000 | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||||
Ricoh | IM 8000 | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||||
Ricoh | IM 7000 | Yes |
Yes |
No |
Yes |
No |
Yes |
Yes |
Yes |
Yes |
No |
Yes |
No |
Yes |
||||
Ricoh | SP C840/SP C842 | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
No |
Yes |
||||
Ricoh | MP C406ZSPF | Yes |
No |
Yes |
Yes |
No |
Yes |
Yes |
No |
Yes |
No |
Yes |
No |
Yes |
||||
Ricoh | MP CW2201 | Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Due device limitation only offline accounting can be used.
|
|||
Ricoh | MP 3055 | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-2553 | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Ricoh Embedded terminal:
- Java J/SDK 12.x and HDD required
Ricoh SOP Embedded terminal:
- J/SDK is optional.
|
||
Ricoh | MP C2504, C2504ex, C2504sp | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3004 | Yes |
Yes |
FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. Driver can be set for offline copy accounting. | Yes |
Yes |
No |
Yes |
Yes |
Yes |
|
|
Ricoh | MP C2004 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3004 | Yes |
Yes |
FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. Driver can be set for offline copy accounting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Ricoh Embedded terminal:
- Java J/SDK 12.x and HDD required
Ricoh SOP Embedded terminal:
- J/SDK is optional.
|
|
Ricoh | MP C307 | Yes |
No |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A4-MPC306 | Yes |
Yes |
Recommended driver: RICOH-MFP-COL-A4-MPC306 Limitations: All counters start with 1 | Yes |
Yes |
No |
No |
Yes |
Yes |
Ricoh Embedded terminal:
- Java J/SDK 12.x and HDD required
Ricoh SOP Embedded terminal:
- J/SDK is optional.
Advanced Finishing Options not tested.
|
|
Ricoh | Aficio MP C7501 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COLOR-4000, RICOH-C6501-FIERY | No |
No |
Recommended driver:RICOH-MFP-COLOR-4000 With Fiery:RICOH-C6501-FIERY Limitations:This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal. | Yes |
Untested |
No |
No |
Yes |
Yes |
SDK 7.x HDD required. Display: WVGA (800x480)
|
|
Ricoh | MP 601SPF | No |
No |
No |
Yes |
No |
RICOH-MFP-BW-A4-DUP-501SPF | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Ricoh Embedded terminal:
- Java J/SDK 12.x and HDD required
Ricoh SOP Embedded terminal:
- J/SDK is optional.
|
||
Ricoh | MP 501SPF | No |
No |
No |
Yes |
No |
RICOH-MFP-BW-A4-DUP-501SPF | Yes |
Yes |
Yes |
Yes |
No |
No |
Yes |
Yes |
Ricoh Embedded terminal:
- Java J/SDK 12.x and HDD required
Ricoh SOP Embedded terminal:
- J/SDK is optional.
|
||
Ricoh | MP C6004 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3004 | Yes |
Yes |
Recommended driver: RICOH-MFP-COL-A3-C3004 Limitations: FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Ricoh Embedded Terminal
SDK/J 12.x HDD required
Ricoh SOP Embedded Terminal
Tested FW version: 1.34
SafeQ 6 build 46 to 48 requires the EAP license “YSQL6-083-0000”. General availability is from build 49.
Web API token in Build 46 has only limited validity (2 months), after 2 months a new token with 2 years validity has to be obtained (or update to a newer Build has to be performed).
Charging and quotas are not supported.
J/SDK is optional.
|
|
Ricoh | MP C5504 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3004 | No |
No |
Recommended driver: RICOH-MFP-COL-A3-C3004 Limitations: FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Ricoh Embedded Terminal
SDK/J 12.x HDD required
Ricoh SOP Embedded Terminal
Tested FW version: 1.34
SafeQ 6 build 46 to 48 requires the EAP license “YSQL6-083-0000”. General availability is from build 49.
Web API token in Build 46 has only limited validity (2 months), after 2 months a new token with 2 years validity has to be obtained (or update to a newer Build has to be performed).
Charging and quotas are not supported.
J/SDK is optional.
|
|
Ricoh | MP C4504 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3004 | No |
No |
Recommended driver: RICOH-MFP-COL-A3-C3004 Limitations: FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Ricoh Embedded Terminal
SDK/J 12.x HDD required
Ricoh SOP Embedded Terminal
Tested FW version: 1.34
SafeQ 6 build 46 to 48 requires the EAP license “YSQL6-083-0000”. General availability is from build 49.
Web API token in Build 46 has only limited validity (2 months), after 2 months a new token with 2 years validity has to be obtained (or update to a newer Build has to be performed).
Charging and quotas are not supported.
J/SDK is optional.
|
|
Ricoh | MP C3504 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3004 | Yes |
Yes |
Recommended driver: RICOH-MFP-COL-A3-C3004 Limitations: FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting. | Yes |
Yes |
No |
No |
Yes |
Yes |
|
|
Ricoh | MP C3004 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3004 | Yes |
Yes |
Recommended driver: RICOH-MFP-COL-A3-C3004 Limitations: FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. Driver can be set for offline copy accounting. | Yes |
Yes |
No |
No |
Yes |
Yes |
Ricoh Embedded Terminal
SDK/J 12.x HDD required
Ricoh SOP Embedded Terminal
Tested FW version: 1.34
SafeQ 6 build 46 to 48 requires the EAP license “YSQL6-083-0000”. General availability is from build 49.
Web API token in Build 46 has only limited validity (2 months), after 2 months a new token with 2 years validity has to be obtained (or update to a newer Build has to be performed).
Charging and quotas are not supported.
J/SDK is optional.
|
|
Ricoh | MP 305+SPF | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-MP305 | Yes |
Yes |
Recommended driver:RICOH-MFP-BW-A3-MP305 Limitations:Each A3 page is accounted as two A4 pages.Scan counters start with 1. | Yes |
Untested |
No |
No |
Yes |
Yes |
Ricoh Embedded terminal: - Java J/SDK 12.x and HDD required Ricoh SOP Embedded terminal: - J/SDK is optional. |
|
Ricoh | MP 305+SP | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-MP305 | Yes |
Yes |
Recommended driver:RICOH-MFP-BW-A3-MP305 Limitations:Each A3 page is accounted as two A4 pages.Scan counters start with 1. | Yes |
Untested |
No |
No |
Yes |
Yes |
Ricoh Embedded terminal: - Java J/SDK 12.x and HDD required Ricoh SOP Embedded terminal: - J/SDK is optional. |
|
Ricoh | SP 6430DN | No |
Yes |
No |
Yes |
Yes |
RICOH-PRN-BW-A3-6330 | No |
No |
Recommended driver: RICOH-PRN-BW-A3-6330 ( RICOH-PRN-BW-A3-TYPE05-beta also available) | No |
Untested |
No |
No |
No |
No |
||
Ricoh | SP C440DN | No |
No |
Yes |
Yes |
Yes |
RICOH-PRN-COL-A4-C440 | No |
No |
Recommended driver: RICOH-PRN-COL-A4-C440 Limitations: If device runs out of paper during print/copy, jobs are accounted after the paper is refilled. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | SP 4510DN | No |
No |
No |
Yes |
No |
RICOH-PRN-BW-A4-4310 | No |
No |
No |
Untested |
No |
No |
No |
No |
|||
Ricoh | MP 401SPF | Yes |
No |
No |
Yes |
Yes |
RICOH-MFP-BW-A4-DUP-401SPF | No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
|||
Ricoh | SP 4510SF | Yes |
No |
No |
Yes |
Yes |
RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required Display: uWVGA (480pxx272)
|
||
Ricoh | MP C2011 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3003, RICOH-MFP-COL-A3-C3003v2 | No |
No |
Recommended driver for SafeQ4/5:RICOH-MFP-COL-A3-C3003 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting.MoFALSEcolor print/copy counters start with 1. Recommended driver for SafeQ 3.6:RICOH-MFP-COL-A3-C3003v2 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Duplex jobs having odd number of pages can be accounted with one more black and white page.Driver can be set for offline copy accounting.MoFALSEcolor print / copy is accounted as color. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Aficio MP 6054ZSP | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Aficio MP 5054ZSP | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Aficio MP 4054ZSP | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Aficio MP 3554ZSP | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Aficio MP 3054ZSP | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Aficio MP 2554ZSP | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Aficio MP 6054 | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 12.x HDD required. Display: WVGA (800x480) Embedded Terminal for SafeQ 5 is supported from Maintenance Update 12.Embedded Terminal for SafeQ 4 is supported from Service Release 44 USB card reader setting: Open [User Tools/Counter/Enquiry] > [System Settings] > [General Features] > [Program/Change USB Device List]. Change Device vendor ID and product ID of the USB device.YSoft Card readers:Vendor ID: 0x214cProduct ID: 0x0202Please note that the Vendor ID and Product ID have to be set just for device1 or for device2 (not for both at same time).
|
|
Ricoh | Aficio MP 5054 | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 12.x HDD required. Display: WVGA (800x480) Embedded Terminal for SafeQ 5 is supported from Maintenance Update 12.Embedded Terminal for SafeQ 4 is supported from Service Release 44 USB card reader setting: Open [User Tools/Counter/Enquiry] > [System Settings] > [General Features] > [Program/Change USB Device List]. Change Device vendor ID and product ID of the USB device.YSoft Card readers:Vendor ID: 0x214cProduct ID: 0x0202Please note that the Vendor ID and Product ID have to be set just for device1 or for device2 (not for both at same time).
|
|
Ricoh | Aficio MP 4054 | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 12.x HDD required. Display: WVGA (800x480) Embedded Terminal for SafeQ 5 is supported from Maintenance Update 12.Embedded Terminal for SafeQ 4 is supported from Service Release 44 USB card reader setting: Open [User Tools/Counter/Enquiry] > [System Settings] > [General Features] > [Program/Change USB Device List]. Change Device vendor ID and product ID of the USB device.YSoft Card readers:Vendor ID: 0x214cProduct ID: 0x0202Please note that the Vendor ID and Product ID have to be set just for device1 or for device2 (not for both at same time).
|
|
Ricoh | Aficio MP 3554 | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 12.x HDD required. Display: WVGA (800x480) Embedded Terminal for SafeQ 5 is supported from Maintenance Update 12.Embedded Terminal for SafeQ 4 is supported from Service Release 44 USB card reader setting: Open [User Tools/Counter/Enquiry] > [System Settings] > [General Features] > [Program/Change USB Device List]. Change Device vendor ID and product ID of the USB device.YSoft Card readers:Vendor ID: 0x214cProduct ID: 0x0202Please note that the Vendor ID and Product ID have to be set just for device1 or for device2 (not for both at same time).
|
|
Ricoh | Aficio MP 3054 | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 12.x HDD required. Display: WVGA (800x480) Embedded Terminal for SafeQ 5 is supported from Maintenance Update 12.Embedded Terminal for SafeQ 4 is supported from Service Release 44 USB card reader setting: Open [User Tools/Counter/Enquiry] > [System Settings] > [General Features] > [Program/Change USB Device List]. Change Device vendor ID and product ID of the USB device.YSoft Card readers:Vendor ID: 0x214cProduct ID: 0x0202Please note that the Vendor ID and Product ID have to be set just for device1 or for device2 (not for both at same time).
|
|
Ricoh | Aficio MP 2554 | Yes |
Yes |
No |
Yes |
Yes |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 12.x HDD required. Display: WVGA (800x480) Embedded Terminal for SafeQ 5 is supported from Maintenance Update 12.Embedded Terminal for SafeQ 4 is supported from Service Release 44 USB card reader setting: Open [User Tools/Counter/Enquiry] > [System Settings] > [General Features] > [Program/Change USB Device List]. Change Device vendor ID and product ID of the USB device.YSoft Card readers:Vendor ID: 0x214cProduct ID: 0x0202Please note that the Vendor ID and Product ID have to be set just for device1 or for device2 (not for both at same time).
|
|
Ricoh | Aficio MP C2503 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3003v2 | No |
No |
Recommended driver:RICOH-MFP-COL-A3-C3003v2 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Duplex jobs having odd number of pages can be accounted with one more black and white page.Driver can be set for offline copy accounting.MoFALSEcolor print / copy is accounted as color. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480) Optional Counter Interface Type A needs to be installed on device for 20pin connector. Embedded Terminal for SafeQ 5 is supported from Service Release 3.
|
|
Ricoh | Aficio MP C2003 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3003v2 | No |
No |
Recommended driver:RICOH-MFP-COL-A3-C3003v2 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Duplex jobs having odd number of pages can be accounted with one more black and white page.Driver can be set for offline copy accounting.MoFALSEcolor print / copy is accounted as color. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480) Optional Counter Interface Type A needs to be installed on device for 20pin connector. Embedded Terminal for SafeQ 5 is supported from Service Release 3.
|
|
Ricoh | Aficio MP 3353ZSP | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Aficio MP 2553ZSP | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Aficio MP 3353SP | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480) Embedded Terminal for SafeQ 5 is supported from Service Release 3.
|
|
Ricoh | Aficio MP 3353 | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480) Embedded Terminal for SafeQ 5 is supported from Service Release 3.
|
|
Ricoh | Aficio MP 3053SP | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480) Embedded Terminal for SafeQ 5 is supported from Service Release 3.
|
|
Ricoh | Aficio MP 3053 | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480) Embedded Terminal for SafeQ 5 is supported from Service Release 3.
|
|
Ricoh | Aficio MP 2553 | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-2553, RICOH-MFP-BW-A4-DUP-5200 | No |
No |
Recommended driver for SafeQ4/5: RICOH-MFP-BW-A3-2553 Recommended driver for SafeQ 3.6: RICOH-MFP-BW-A4-DUP-5200 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480) Embedded Terminal for SafeQ 5 is supported from Service Release 3.
|
|
Ricoh | Aficio MP W3600 | Yes |
No |
No |
Yes |
No |
RICOH-MFP-BW-A3-W2400 | No |
No |
Recommended driver:RICOH-MFP-BW-A3-W2400 Limitations:Accounting counter must be set to A3 area.Each 2 A4 pages are accounted as 1 A3 page. If job has odd number of pages then last page is FALSEt accounted or is accounted as one A3 page. This accounting inaccuracy is caused by device limitation.Each A2 page is accounted as 2 A3 pages.Each A1 page is accounted as 4 A3 pages.Each A0 page is accounted as 8 A3 pages.Driver can be set for offline copy accounting.Scan counter starts with 1. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Aficio MP W2400 | Yes |
No |
No |
Yes |
No |
RICOH-MFP-BW-A3-W2400 | No |
No |
Recommended driver:RICOH-MFP-BW-A3-W2400 Limitations:Accounting counter must be set to A3 area.Each 2 A4 pages are accounted as 1 A3 page. If job has odd number of pages then last page is FALSEt accounted or is accounted as one A3 page. This accounting inaccuracy is caused by device limitation.Each A2 page is accounted as 2 A3 pages.Each A1 page is accounted as 4 A3 pages.Each A0 page is accounted as 8 A3 pages.Driver can be set for offline copy accounting.Scan counter starts with 1. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Pro 1357EXP | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-1357EX | No |
No |
Recommended driver:RICOH-MFP-BW-A3-1357EX Limitations:This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal.Status detection during scan/copy FALSEt supported.FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Pro 1357EX | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-1357EX | No |
No |
Recommended driver:RICOH-MFP-BW-A3-1357EX Limitations:This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal.Status detection during scan/copy FALSEt supported.FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Pro 1107EXP | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-1357EX | No |
No |
Recommended driver:RICOH-MFP-BW-A3-1357EX Limitations:This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal.Status detection during scan/copy FALSEt supported.FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Pro 1107EX | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-1357EX | No |
No |
Recommended driver:RICOH-MFP-BW-A3-1357EX Limitations:This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal.Status detection during scan/copy FALSEt supported.FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Pro 907EXP | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-1357EX | No |
No |
Recommended driver:RICOH-MFP-BW-A3-1357EX Limitations:This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal.Status detection during scan/copy FALSEt supported.FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Pro 907EX | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-1357EX | No |
No |
Recommended driver:RICOH-MFP-BW-A3-1357EX Limitations:This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal.Status detection during scan/copy FALSEt supported.FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Aficio MP C8002 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-MPC6502 | No |
No |
Recommended driver:RICOH-MFP-COL-A3-MPC6502 Limitations:This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal.Single color is accounted as moFALSEchrome. Two-color is accounted as moFALSEchrome. A3 print/copy is accounted as 2xA4 print/copy. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480)
|
|
Ricoh | Aficio MP C6502 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-MPC6502 | No |
No |
Recommended driver:RICOH-MFP-COL-A3-MPC6502 Limitations:This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal.Single color is accounted as moFALSEchrome. Two-color is accounted as moFALSEchrome. A3 print/copy is accounted as 2xA4 print/copy. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480)
|
|
Ricoh | Pro 8120s | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-8100S | No |
No |
Recommended driver: RICOH-MFP-BW-A3-8100S Limitations: This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal. Login during incoming/outgoing FAX is possible. Driver can be set for offline copy accounting. Scan counter starts with 1. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Pro 8110s | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-8100S | No |
No |
Recommended driver: RICOH-MFP-BW-A3-8100S Limitations: This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal. Login during incoming/outgoing FAX is possible. Driver can be set for offline copy accounting. Scan counter starts with 1. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Pro 8100s | Yes |
Yes |
No |
Yes |
No |
RICOH-MFP-BW-A3-8100S | No |
No |
Recommended driver: RICOH-MFP-BW-A3-8100S Limitations: This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal. Login during incoming/outgoing FAX is possible. Driver can be set for offline copy accounting. Scan counter starts with 1. | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Pro C5100S (E-22B controller) | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C5100S | No |
No |
Recommended driver:RICOH-MFP-COL-A3-C5100S Limitations:This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal.There is a 3 second timeout after print.There is a 3 second timeout after copy.FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Duplex jobs having odd number of pages can be accounted with one more black and white page.Driver can be set for offline copy accounting.Single color is accounted as moFALSEchrome.Two-color is accounted as full color. | Yes |
Yes |
No |
No |
Yes |
No |
HDD required. Display: WVGA (800x480)
|
|
Ricoh | Pro C5100S | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-MPC6502 | No |
No |
Recommended driver:RICOH-MFP-COL-A3-MPC6502 Limitations:This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal.Single color is accounted as moFALSEchrome. Two-color is accounted as moFALSEchrome. A3 print/copy is accounted as 2xA4 print/copy. | Yes |
Yes |
No |
No |
Yes |
No |
HDD required. Display: WVGA (800x480)
|
|
Ricoh | Aficio MP CW2200SP | Yes |
No |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-CW2200SP | No |
No |
Recommended driver: RICOH-MFP-COL-A3-CW2200SP Limitations:This driver canFALSEt be used with SafeQ 3.6 with Embedded Terminal.Accounting counter must be set to A3 area.Each 2 A4 pages are accounted as 1 A3 page. If job has odd number of pages then last page is FALSEt accounted or is accounted as one A3 page. This accounting inaccuracy is caused by device limitation.Each A2 page is accounted as 2 A3 pages.Each A1 page is accounted as 4 A3 pages.Each A0 page is accounted as 8 A3 pages.Driver can be set for offline copy accounting.MoFALSEcolor print/copy counters start with 1.Scan counter starts with 1. | Yes |
Yes |
No |
No |
Yes |
Yes |
HDD required. Display: WVGA (800x480) SafeQ 4 SR 25 or newer required for terminal embedded support. Counter unit 5-045-002 has to be set on value 6. All pages are accounted as in A3 format.
|
|
Ricoh | Aficio MP C6003 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3003, RICOH-MFP-COL-A3-C3003v2 | No |
No |
Recommended driver for SafeQ4/5:RICOH-MFP-COL-A3-C3003 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting.MoFALSEcolor print/copy counters start with 1. Recommended driver for SafeQ 3.6:RICOH-MFP-COL-A3-C3003v2 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Duplex jobs having odd number of pages can be accounted with one more black and white page.Driver can be set for offline copy accounting.MoFALSEcolor print / copy is accounted as color. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480) Optional Counter Interface Type A needs to be installed on device for 20pin connector. The 4pin cable connector might require modification to fit into the connector on device SafeQ 4 SR 25 or newer required for terminal embedded support.
|
|
Ricoh | Aficio MP C5503 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3003, RICOH-MFP-COL-A3-C3003v2 | No |
No |
Recommended driver for SafeQ4/5:RICOH-MFP-COL-A3-C3003 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting.MoFALSEcolor print/copy counters start with 1. Recommended driver for SafeQ 3.6:RICOH-MFP-COL-A3-C3003v2 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Duplex jobs having odd number of pages can be accounted with one more black and white page.Driver can be set for offline copy accounting.MoFALSEcolor print / copy is accounted as color. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480) Optional Counter Interface Type A needs to be installed on device for 20pin connector. The 4pin cable connector might require modification to fit into the connector on device SafeQ 4 SR 25 or newer required for terminal embedded support.
|
|
Ricoh | Aficio MP C4503 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3003, RICOH-MFP-COL-A3-C3003v2 | No |
No |
Recommended driver for SafeQ4/5:RICOH-MFP-COL-A3-C3003 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting.MoFALSEcolor print/copy counters start with 1. Recommended driver for SafeQ 3.6:RICOH-MFP-COL-A3-C3003v2 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Duplex jobs having odd number of pages can be accounted with one more black and white page.Driver can be set for offline copy accounting.MoFALSEcolor print / copy is accounted as color. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480) Optional Counter Interface Type A needs to be installed on device for 20pin connector. The 4pin cable connector might require modification to fit into the connector on device SafeQ 4 SR 25 or newer required for terminal embedded support.
|
|
Ricoh | Aficio MP C3503 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3003, RICOH-MFP-COL-A3-C3003v2 | No |
No |
Recommended driver for SafeQ4/5:RICOH-MFP-COL-A3-C3003 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting.MoFALSEcolor print/copy counters start with 1. Recommended driver for SafeQ 3.6:RICOH-MFP-COL-A3-C3003v2 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Duplex jobs having odd number of pages can be accounted with one more black and white page.Driver can be set for offline copy accounting.MoFALSEcolor print / copy is accounted as color. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480) Optional Counter Interface Type A needs to be installed on device for 20pin connector. The 4pin cable connector might require modification to fit into the connector on device SafeQ 4 SR 25 or newer required for terminal embedded support.
|
|
Ricoh | Aficio MP C3003 | Yes |
Yes |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A3-C3003, RICOH-MFP-COL-A3-C3003v2 | No |
No |
Recommended driver for SafeQ4/5:RICOH-MFP-COL-A3-C3003 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Driver can be set for offline copy accounting.MoFALSEcolor print/copy counters start with 1. Recommended driver for SafeQ 3.6:RICOH-MFP-COL-A3-C3003v2 Limitations:FALSE separate counters for A3. Device accounts A3 pages as one or two A4 pages depending on device configuration.Duplex jobs having odd number of pages can be accounted with one more black and white page.Driver can be set for offline copy accounting.MoFALSEcolor print / copy is accounted as color. | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 11.x HDD required. Display: WVGA (800x480) Optional Counter Interface Type A needs to be installed on device for 20pin connector. The 4pin cable connector might require modification to fit into the connector on device SafeQ 4 SR 25 or newer required for terminal embedded support.
|
|
Ricoh | Aficio SP 4310DN | No |
No |
No |
Yes |
No |
RICOH-PRN-BW-A4-4310 | No |
No |
Recommended driver:RICOH-PRN-BW-A4-4310 ( RICOH-PRN-BW-A4-TYPE04-beta also available ) | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Aficio SP 4310N | No |
No |
No |
Yes |
No |
RICOH-PRN-BW-A4-4310 | No |
No |
Recommended driver:RICOH-PRN-BW-A4-4310 ( RICOH-PRN-BW-A4-TYPE04-beta also available ) | No |
Untested |
No |
No |
No |
No |
||
Ricoh | Aficio MPC 306ZSPF | Yes |
No |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A4-MPC306 | No |
No |
Recommended driver:RICOH-MFP-COL-A4-MPC306 Limitations:All counters start with 1 OPTIONNAL COUNTER UNIT M12 | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 12.x Embedded Terminal limitations: Scan from glass is not possible via SafeQ aplication (scan from ADF is possible). Logout by Android OS logout button (upper right corner) is possible only from SafeQ application. Embedded Terminal recommendations: After installing ET set function priority to SafeQ. Before uninstalling ET set function priority to some other application than SafeQ. USB card reader setting: Open [User Tools/Counter/Enquiry] > [System Settings] > [General Features] > [Program/Change USB Device List]. Change Device vendor ID and product ID of the USB device.YSoft Card readers:Vendor ID: 0x214cProduct ID: 0x0202Please note that the Vendor ID and Product ID have to be set just for device1 or for device2 (not for both at same time).
|
|
Ricoh | Aficio MP C306ZSP | Yes |
No |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A4-MPC306 | Yes |
Yes |
Recommended driver: RICOH-MFP-COL-A4-MPC306 Limitations: All counters start with 1 OPTIONNAL COUNTER UNIT M12 required for blocking | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 12.x Embedded Terminal limitations: Scan from glass is not possible via SafeQ aplication (scan from ADF is possible). Logout by Android OS logout button (upper right corner) is possible only from SafeQ application. Embedded Terminal recommendations: After installing ET set function priority to SafeQ. Before uninstalling ET set function priority to some other application than SafeQ. USB card reader setting: Open [User Tools/Counter/Enquiry] > [System Settings] > [General Features] > [Program/Change USB Device List]. Change Device vendor ID and product ID of the USB device.YSoft Card readers:Vendor ID: 0x214cProduct ID: 0x0202Please note that the Vendor ID and Product ID have to be set just for device1 or for device2 (not for both at same time).
|
|
Ricoh | Aficio MPC 305SP | Yes |
No |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A4-MPC305 | No |
No |
Recommended driver:RICOH-MFP-COL-A4-MPC305 Limitations:MoFALSEcolor counters start with 1 | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 10.x HDD required Display: uWVGA (480pxx272) Optional Counter Interface Type A needs to be installed on device for 20pin connector.
|
|
Ricoh | Aficio MPC 305SPF | Yes |
No |
Yes |
Yes |
Yes |
RICOH-MFP-COL-A4-MPC305 | No |
No |
Recommended driver:RICOH-MFP-COL-A4-MPC305 Limitations:MoFALSEcolor counters start with 1 | Yes |
Yes |
No |
No |
Yes |
Yes |
SDK 10.x HDD required Display: uWVGA (480pxx272) Optional Counter Interface Type A needs to be installed on device for 20pin connector.
|
Additional notes
LEXMARK 6224de
Embedded terminal not supported.